SearcharxivSearch

arXiv subjects

Jiewen Lai

Publications and source records attributed to Jiewen Lai.

13 recordsLinked to original sources

Trajectory Divergence Horizon Decision for Reliable Dual-Arm Surgical Subtask Manipulation

Surgical robotic systems are increasingly being adopted as clinical workload rises, motivating autonomous solutions for repetitive manipulation subtasks. Learning-based controllers improve generalization compared with rule-based and analytic approaches, but most are trained for individual tasks and remain difficult to reuse across procedures. Vision-Language-Action (VLA) models provide a unified framework that integrates visual perception, language grounding, and action generation, offering a promising path toward more composable surgical autonomy. However, existing VLA policies rely on fixed-length open-loop action sequences, where changing scene conditions can lead to accumulated errors and potential risks in surgical manipulation. To mitigate this issue, we formulate surgical VLA deployment as an adaptive execution-horizon decision problem and propose Trajectory Divergence Horizon Decision (TDHD), a test-time mechanism that estimates step-wise action reliability by measuring the divergence between two flow-matching-generated trajectories under small noise perturbations and truncates execution using a dual-threshold rule to trigger timely replanning. We further establish a real-world da Vinci-like dual-arm benchmark with synchronized multi-view perception and language instructions, and collect 600 teleoperated demonstrations across needle (reach, pick, regrasp) and tissue (reach, lift, resection) manipulation suites. On real hardware with 20 trials per task setting, TDHD consistently improves performance over the latest VLA baselines: success increases from 55\% to 60\% for needle manipulation and from 55\% to 80\% for tissue manipulation, with the largest gains observed in the final manipulation stages. These results highlight the importance of adaptive execution control for reliable deployment of VLA models in surgical robotic manipulation.

cs.RO

BiliVLA: Scene-Aware Vision-Language-Action Model with Reinforcement Learning for Autonomous Biliary Endoscopic Navigation

Endoscopic retrograde cholangiopancreatography (ERCP) demands precise endoscopic navigation and stable biliary cannulation within a narrow monocular field characterized by specular reflections, partial occlusions, and frequent tissue contact. Although recent robotic systems and vision-based assistance techniques improve operator ergonomics and provide perceptual cues, their performance degrades under pronounced anatomical variability and safety-critical visual artifacts, which hinders reliable autonomy in cannulation-grade procedures. Here, we present BiliVLA, a scene-aware Vision-Language-Action (VLA) framework that formulates biliary endoscopic navigation as an instruction-conditioned visuomotor learning problem. Given an endoscopic observation and a stage-specific language instruction, BiliVLA jointly predicts the target category, a grounded bounding box, and a discrete three-degree-of-freedom (3-DoF) motor command for a continuum endoscope. The proposed framework incorporates scene-aware supervision to improve semantic target consistency and safety-aware recovery supervision to induce conservative retreat behaviors under luminal wall contact. A key component of BiliVLA is a two-stage training paradigm that combines grounding-enhanced supervised fine-tuning (SFT) with Group Relative Policy Optimization (GRPO), thereby improving action reliability and decision consistency during closed-loop navigation. Across three ERCP subtasks, BiliVLA achieves the best overall performance in physical phantom experiments, with a total mIoU of 0.9625, an overall action precision of 91.96\%, and an overall success rate (SR) of 84.85\%. These results indicate that integrating semantic grounding, scene-aware learning, and reward-guided optimization strengthens perception--action alignment and enables more robust autonomous biliary endoscopic navigation.

cs.RO

GeoCFNet: Geometry-Aware Confidence Field Network for Robot-Assisted Endoscopic Submucosal Dissection

Advanced surgical robotics has made robot-assisted endoscopic submucosal dissection (ESD) a promising approach for the en-bloc resection of large lesions, with the potential to reduce recurrence and improve long-term outcomes. However, the technical complexity and risk of complications in ESD demand stable and precise visual guidance to maintain an accurate dissection corridor and a safe tissue margin. Dense confidence fields provide an effective representation for this purpose by describing both the preferred dissection region and its spatial transition to surrounding tissue. However, reliable confidence field estimation remains challenging in dynamic endoscopic scenes due to smoke, specular highlights, tissue deformation, weak texture, and the thin geometric structure of the target region. To address these challenges, we formulate dissection guidance as a geometry-aware confidence field estimation problem and propose GeoCFNet, a geometry-aware confidence field network built on a pretrained DINOv3 backbone. GeoCFNet integrates a Token-Differentiated Fusion module to aggregate class-token context with dense patch representations, a SegFormer decoder for confidence regression, and Geometry-Aware Spatial Regularization (GASR) to preserve spatial coherence and local geometric transitions. Experimental results show that GeoCFNet achieves RMSE 0.0480, PSNR 27.1995, SSIM 0.3397, and CC 0.2466, indicating accurate and geometrically stable confidence field estimation for robot-assisted ESD guidance.

cs.CV

EndoDDC: Learning Sparse to Dense Reconstruction for Endoscopic Robotic Navigation via Diffusion Depth Completion

Accurate depth estimation plays a critical role in the navigation of endoscopic surgical robots, forming the foundation for 3D reconstruction and safe instrument guidance. Fine-tuning pretrained models heavily relies on endoscopic surgical datasets with precise depth annotations. While existing self-supervised depth estimation techniques eliminate the need for accurate depth annotations, their performance degrades in environments with weak textures and variable lighting, leading to sparse reconstruction with invalid depth estimation. Depth completion using sparse depth maps can mitigate these issues and improve accuracy. Despite the advances in depth completion techniques in general fields, their application in endoscopy remains limited. To overcome these limitations, we propose EndoDDC, an endoscopy depth completion method that integrates images, sparse depth information with depth gradient features, and optimizes depth maps through a diffusion model, addressing the issues of weak texture and light reflection in endoscopic environments. Extensive experiments on two publicly available endoscopy datasets show that our approach outperforms state-of-the-art models in both depth accuracy and robustness. This demonstrates the potential of our method to reduce visual errors in complex endoscopic environments. Our code will be released at https://github.com/yinheng-lin/EndoDDC.

cs.CV

GeoLanG: Geometry-Aware Language-Guided Grasping with Unified RGB-D Multimodal Learning

Language-guided grasping has emerged as a promising paradigm for enabling robots to identify and manipulate target objects through natural language instructions, yet it remains highly challenging in cluttered or occluded scenes. Existing methods often rely on multi-stage pipelines that separate object perception and grasping, which leads to limited cross-modal fusion, redundant computation, and poor generalization in cluttered, occluded, or low-texture scenes. To address these limitations, we propose GeoLanG, an end-to-end multi-task framework built upon the CLIP architecture that unifies visual and linguistic inputs into a shared representation space for robust semantic alignment and improved generalization. To enhance target discrimination under occlusion and low-texture conditions, we explore a more effective use of depth information through the Depth-guided Geometric Module (DGGM), which converts depth into explicit geometric priors and injects them into the attention mechanism without additional computational overhead. In addition, we propose Adaptive Dense Channel Integration, which adaptively balances the contributions of multi-layer features to produce more discriminative and generalizable visual representations. Extensive experiments on the OCID-VLG dataset, as well as in both simulation and real-world hardware, demonstrate that GeoLanG enables precise and robust language-guided grasping in complex, cluttered environments, paving the way toward more reliable multimodal robotic manipulation in real-world human-centric settings.

cs.RO

Contact-Aided Navigation of Flexible Robotic Endoscope Using Deep Reinforcement Learning in Dynamic Stomach

Navigating a flexible robotic endoscope (FRE) through the gastrointestinal tract is critical for surgical diagnosis and treatment. However, navigation in the dynamic stomach is particularly challenging because the FRE must learn to effectively use contact with the deformable stomach walls to reach target locations. To address this, we introduce a deep reinforcement learning (DRL) based Contact-Aided Navigation (CAN) strategy for FREs, leveraging contact force feedback to enhance motion stability and navigation precision. The training environment is established using a physics-based finite element method (FEM) simulation of a deformable stomach. Trained with the Proximal Policy Optimization (PPO) algorithm, our approach achieves high navigation success rates (within 3 mm error between the FRE's end-effector and target) and significantly outperforms baseline policies. In both static and dynamic stomach environments, the CAN agent achieved a 100% success rate with 1.6 mm average error, and it maintained an 85% success rate in challenging unseen scenarios with stronger external disturbances. These results validate that the DRL-based CAN strategy substantially enhances FRE navigation performance over prior methods.

cs.RO

Unlocking Mixed Reality for Medical Education: A See-Through Perspective on Head Anatomy

Extended reality (XR), encompassing Virtual Reality (VR), Augmented Reality (AR), and Mixed Reality (MR), is emerging as a transformative platform for medical education. Traditional methods such as textbooks, physical models, and cadaveric dissections often lack interactivity and fail to convey complex spatial relationships effectively. The emerging MR technology addresses these limitations by providing immersive environments that blend virtual elements with real-world contexts. This study presents an MR application for head anatomy education, enabling learners to intuitively interact with see-through 3D anatomical structures via hand gestures and controllers. Our hierarchical information design supports progressive learning, guiding users from basic anatomical labels to detailed structural insights. Additionally, the system incorporates an automatic calibration module that aligns virtual anatomical models with a real human head, thereby facilitating realistic human-model interactions. Experiments show that the system can effectively match the anatomical model with real-time scenes, thus enhancing the interactivity and immersion of medical education, providing an innovative tool for teaching anatomy.

cs.HC

CapsDT: Diffusion-Transformer for Capsule Robot Manipulation

Vision-Language-Action (VLA) models have emerged as a prominent research area, showcasing significant potential across a variety of applications. However, their performance in endoscopy robotics, particularly endoscopy capsule robots that perform actions within the digestive system, remains unexplored. The integration of VLA models into endoscopy robots allows more intuitive and efficient interactions between human operators and medical devices, improving both diagnostic accuracy and treatment outcomes. In this work, we design CapsDT, a Diffusion Transformer model for capsule robot manipulation in the stomach. By processing interleaved visual inputs, and textual instructions, CapsDT can infer corresponding robotic control signals to facilitate endoscopy tasks. In addition, we developed a capsule endoscopy robot system, a capsule robot controlled by a robotic arm-held magnet, addressing different levels of four endoscopy tasks and creating corresponding capsule robot datasets within the stomach simulator. Comprehensive evaluations on various robotic tasks indicate that CapsDT can serve as a robust vision-language generalist, achieving state-of-the-art performance in various levels of endoscopy tasks while achieving a 26.25% success rate in real-world simulation manipulation.

cs.RO

Multimodal Graph Representation Learning for Robust Surgical Workflow Recognition with Adversarial Feature Disentanglement

Surgical workflow recognition is vital for automating tasks, supporting decision-making, and training novice surgeons, ultimately improving patient safety and standardizing procedures. However, data corruption can lead to performance degradation due to issues like occlusion from bleeding or smoke in surgical scenes and problems with data storage and transmission. In this case, we explore a robust graph-based multimodal approach to integrating vision and kinematic data to enhance accuracy and reliability. Vision data captures dynamic surgical scenes, while kinematic data provides precise movement information, overcoming limitations of visual recognition under adverse conditions. We propose a multimodal Graph Representation network with Adversarial feature Disentanglement (GRAD) for robust surgical workflow recognition in challenging scenarios with domain shifts or corrupted data. Specifically, we introduce a Multimodal Disentanglement Graph Network that captures fine-grained visual information while explicitly modeling the complex relationships between vision and kinematic embeddings through graph-based message modeling. To align feature spaces across modalities, we propose a Vision-Kinematic Adversarial framework that leverages adversarial training to reduce modality gaps and improve feature consistency. Furthermore, we design a Contextual Calibrated Decoder, incorporating temporal and contextual priors to enhance robustness against domain shifts and corrupted data. Extensive comparative and ablation experiments demonstrate the effectiveness of our model and proposed modules. Moreover, our robustness experiments show that our method effectively handles data corruption during storage and transmission, exhibiting excellent stability and robustness. Our approach aims to advance automated surgical workflow recognition, addressing the complexities and dynamism inherent in surgical procedures.

cs.CV

Three-dimensional Morphological Reconstruction of Millimeter-Scale Soft Continuum Robots based on Dual-Stereo-Vision

Continuum robots can be miniaturized to just a few millimeters in diameter. Among these, notched tubular continuum robots (NTCR) show great potential in many delicate applications. Existing works in robotic modeling focus on kinematics and dynamics but still face challenges in reproducing the robot's morphology -- a significant factor that can expand the research landscape of continuum robots, especially for those with asymmetric continuum structures. This paper proposes a dual stereo vision-based method for the three-dimensional morphological reconstruction of millimeter-scale NTCRs. The method employs two oppositely located stationary binocular cameras to capture the point cloud of the NTCR, then utilizes predefined geometry as a reference for the KD tree method to relocate the capture point clouds, resulting in a morphologically correct NTCR despite the low-quality raw point cloud collection. The method has been proved feasible for an NTCR with a 3.5 mm diameter, capturing 14 out of 16 notch features, with the measurements generally centered around the standard of 1.5 mm, demonstrating the capability of revealing morphological details. Our proposed method paves the way for 3D morphological reconstruction of millimeter-scale soft robots for further self-modeling study.

cs.RO

Domain Adaptive Sim-to-Real Segmentation of Oropharyngeal Organs

Video-assisted transoral tracheal intubation (TI) necessitates using an endoscope that helps the physician insert a tracheal tube into the glottis instead of the esophagus. The growing trend of robotic-assisted TI would require a medical robot to distinguish anatomical features like an experienced physician which can be imitated by utilizing supervised deep-learning techniques. However, the real datasets of oropharyngeal organs are often inaccessible due to limited open-source data and patient privacy. In this work, we propose a domain adaptive Sim-to-Real framework called IoU-Ranking Blend-ArtFlow (IRB-AF) for image segmentation of oropharyngeal organs. The framework includes an image blending strategy called IoU-Ranking Blend (IRB) and style-transfer method ArtFlow. Here, IRB alleviates the problem of poor segmentation performance caused by significant datasets domain differences; while ArtFlow is introduced to reduce the discrepancies between datasets further. A virtual oropharynx image dataset generated by the SOFA framework is used as the learning subject for semantic segmentation to deal with the limited availability of actual endoscopic images. We adapted IRB-AF with the state-of-the-art domain adaptive segmentation models. The results demonstrate the superior performance of our approach in further improving the segmentation accuracy and training stability.

cs.AI

Domain Adaptive Sim-to-Real Segmentation of Oropharyngeal Organs Towards Robot-assisted Intubation

Robotic-assisted tracheal intubation requires the robot to distinguish anatomical features like an experienced physician using deep-learning techniques. However, real datasets of oropharyngeal organs are limited due to patient privacy issues, making it challenging to train deep-learning models for accurate image segmentation. We hereby consider generating a new data modality through a virtual environment to assist the training process. Specifically, this work introduces a virtual dataset generated by the Simulation Open Framework Architecture (SOFA) framework to overcome the limited availability of actual endoscopic images. We also propose a domain adaptive Sim-to-Real method for oropharyngeal organ image segmentation, which employs an image blending strategy called IoU-Ranking Blend (IRB) and style-transfer techniques to address discrepancies between datasets. Experimental results demonstrate the superior performance of the proposed approach with domain adaptive models, improving segmentation accuracy and training stability. In the practical application, the trained segmentation model holds great promise for robot-assisted intubation surgery and intelligent surgical navigation.

eess.IV

Constrained Motion Planning of A Cable-Driven Soft Robot With Compressible Curvature Modeling

A cable-driven soft-bodied robot with redundancy can conduct the trajectory tracking task and in the meanwhile fulfill some extra constraints, such as tracking through an end-effector in designated orientation, or get rid of the evitable manipulator-obstacle collision. Those constraints require rational planning of the robot motion. In this work, we derived the compressible curvature kinematics of a cable-driven soft robot which takes the compressible soft segment into account. The motion planning of the soft robot for a trajectory tracking task in constrained conditions, including fixed orientation end-effector and manipulator-obstacle collision avoidance, has been investigated. The inverse solution of cable actuation was formulated as a damped least-square optimization problem and iteratively computed off-line. The performance of trajectory tracking and the obedience to constraints were evaluated via the simulation we made open-source, as well as the prototype experiments. The method can be generalized to the similar multisegment cable-driven soft robotic systems by customizing the robot parameters for the prior motion planning of the manipulator.

cs.RO