SearcharxivSearch

arXiv subjects

Jinchang Liu

Publications and source records attributed to Jinchang Liu.

13 recordsLinked to original sources

Scalable self-testing of generic multipartite quantum states

Characterizing large quantum systems with minimal assumptions is a central challenge in quantum information science. Self-testing provides the strongest form of certification by identifying the underlying quantum state solely from observed measurement statistics. However, existing self-testing methods for generic $n$-partite states face a scalability barrier, requiring exponentially many samples in the system size. In this work, we overcome this barrier by introducing a protocol that robustly self-tests almost all $n$-qubit states with only polynomial sample complexity. The key ingredient is an efficient scheme for device-independently evaluating multipartite Pauli measurements, which can be implemented using only a linear number of ancillary Bell pairs together with standard projective and Bell measurements, well within the reach of current quantum technology. Beyond self-testing states, our scheme provides a general framework for implementing a wide range of learning and certification protocols in the device-independent setting, thereby opening a scalable route to device-independent quantum information processing in large-scale quantum networks.

quant-ph

A Semantic Geometry for Uncovering Paradigm Dynamics via Scientific Publications

Science advances not only by accumulating discovered patterns but by changing how new problems and solutions are expressed. While structural indicators track scholarly attention, they offer only an indirect proxy for the reorganization of meaning. We propose a semantic geometry based on the R-P-C (references, focal publication, and citing publications) framework to quantify how a publication positions itself relative to its knowledge base and diffusion. This geometry identifies three publication types: consolidating, exploratory and balanced. Our results show that the semantic similarity and distance between a publication's knowledge base and diffusion serve as a semantic foundation for disruption, with novelty (atypical reference combinations) acting as an antecedent disturbance that triggers a semantic rupture. This is related to team size, where small teams preserve a higher potential for exploratory departures while large collaborations systematically align with paradigmatic consolidation. Crucially, this geometry explains why citation trajectories differ; consolidating research earns rapid recognition by lowering comprehension costs, while exploratory work faces high paradigm conversion costs that result in slower, more selective diffusion. Collectively, this R-P-C framework provides a robust instrument for monitoring the dynamics of scientific paradigms.

cs.DL

Liquid Handling of the JUNO Experiment

The Filling, Overflow, and Circulation (FOC) system is a critical subsystem of the Jiangmen Underground Neutrino Observatory (JUNO), responsible for the safe handling of the Liquid Scintillator (LS) and water throughout the detector's commissioning and operational lifetime. This paper details the design and operation of the FOC system, which accomplished the filling of the world's largest LS detector--taking 45 days for water (6.4*10^4 m^3) and 200 days for LS (2.3*10^4 m^3). Throughout water filling, the liquid level difference between the Central Detector and Water Pool was rigorously maintained within safety limits. During LS filling, level control achieved +/-2 cm precision with flow regulation within +/-0.5% of setpoints. An automated control system based on Programmable Logic Controllers and the Experimental Physics and Industrial Control System framework ensured reliable operation. The system preserved LS radiopurity, maintaining 222Rn below 1 mBq/m^3 during filling and achieving 238U/232Th concentrations below 10^-16 g/g. The successful commissioning and operation of the FOC system have established it as an indispensable foundation for the stable long-term operation of the JUNO detector.

physics.ins-det

Certifying localizable quantum properties with constant sample complexity

Characterizing increasingly complex quantum systems is a central task in quantum information science, yet experimental costs often scale prohibitively with system size. Certifying key properties using simple local measurements is highly desirable but challenging. In this work, we introduce a highly general certification framework based on a physical phenomenon that we call localizable quantumness: for generic many-body states, essential quantum properties are robustly preserved within the projected ensembles on small subsystems after performing local projective measurements on the rest of the system. Leveraging this insight, we develop protocols to certify global properties -- including multipartite entanglement, circuit complexity, and quantum magic -- by witnessing them on a small, accessible subsystem. Remarkably, randomizing the local measurement bases extends this capability to certify state fidelity. Relying solely on local Pauli measurements, these protocols achieve constant sample complexity and robustness for almost all quantum states, including a wide range of physically relevant states. For certifying the fidelity of $n$-qubit states, this $O(1)$ scaling dramatically improves upon state-of-the-art protocols requiring $O(n^4)$ samples. Our unified framework provides both a practical toolkit for large-scale quantum certification and a novel lens into complex many-body systems.

quant-ph

Study on the radon adsorption capability of low-background activated carbon

Radon is a significant background source in rare event detection experiments. Activated Carbon (AC) adsorption is widely used for effective radon removal. The selection of AC considers its adsorption capacity and radioactive background. In this study, using self-developed devices, we screened and identified a new kind of low-background AC from Qingdao Inaf Technology Company that has very high Radon adsorption capacity. By adjusting the average pore size to 2.3 nm, this AC demonstrates a radon adsorption capacity of 2.6 or 4.7 times higher than Saratech or Carboact activated carbon under the same conditions.

hep-ex

Imaging of muon track in CsI(Tl) crystal with single photon sensitive camera

As a novel approach on visual photon imaging by a single photon sensitive camera and PMTs, this work is trying to measure and identify muon tracks from the 2-D images of CsI(Tl) crystal (scintillator detectors). It is possible that muon tracks can be seen directly with a good signal-to-noise ratio neither with further amplification nor external light, which provides an evolution method for particle measurement in the photon-starved regime of scintillation detectors. The setup of the crystal and camera testing system and the identification algorithm of muon track will be discussed in detail including the system calibration, identification model, signal-to-noise ratio, muon track confirmation, and an expectation on further improvements and applications.

physics.ins-det

Performance of compact plastic scintillator strips with WLS-fiber and PMT/SiPM readout

This work presents the design and performance study of compact strips of plastic scintillator with WLS-fiber readout in a dimension of 0.1 * 0.02 * 2 m3, which evaluates as a candidate for cosmic-ray muon detector for JUNO-TAO. The strips coupling with 3-inch PMTs are measured and compared between the single-end and double-end readout options first, and the strip of double-end option coupling with SiPM is further measured and compared with the results of that with the PMTs. The performance of the strips determined by a detailed survey along their length with cosmic-ray muon after a detailed characterization of the used 3-inch PMTs and SiPMs.The proposed compact strip of plastic scintillator with WLS-fiber coupling with SiPM provides a good choice for cosmic-ray muon veto detector for limited detector dimension in particular.

physics.ins-det

Imaging of CsI(Tl) crystal event and double-slit Young's interference by a single photon sensitive camera

We will discuss an imaging measurement with a single photon sensitive and low noise camera aiming to a new paradigm in the optical readout of scintillation detectors. The features of the single photon sensitive camera will be characterized and demonstrated with a measurement on double-slit Young's interference in single photon mode. An imaging test on CsI(Tl) crystal and alpha source will be performed further for preliminary measurements on the noise level and sensitivity of the system with a 1/2", f/1.4 lens, which reaches an sensitivity on light intensity around 1/10 of the 3-inch PMT and shows a potential to realize an imaging of single alpha event. An application proposal to scintillation detectors will be further discussed, where it is usually assumed that the imaging is not possible in such a photon-starved and large-emittance regime.

physics.ins-det

Developing the radium measurement system for the water Cherenkov detector of the Jiangmen Underground Neutrino Observatory

The Jiangmen Underground Neutrino Observatory is proposed to determine neutrino mass hierarchy using a 20~ktonne liquid scintillator detector. Strict radio-purity requirements have been put forward for all the components of the detector. According to the MC simulation results, the radon dissolved in the water Cherenkov detector should be below 200~mBq/m$^3$. Radium, the progenitor of radon, should also be taken seriously into account. In order to measure the radium concentration in water, a radium measurement system, which consists of a radium extraction system, a radon emanation chamber and a radon concentration measurement system, has been developed. In this paper, the updated radon concentration in gas measurement system with a one-day-measurement sensitivity of $\sim$5~mBq/m$^3$, the detail of the development of the radium concentration in water measurement system with a sensitivity of $\sim$23~mBq/m$^3$ as well as the measurement results of Daya Bay water samples will be presented.

astro-ph.IM

Calibration of liquid argon detector with $^{83m}Kr$ and $^{22}Na$ in different drift field

$^{83m}Kr$ and $^{22}Na$ have been used in calibrating a liquid argon (LAr) detector.$^{83m}Kr$ atoms are produced through the decay of $^{83}Rb$ and introduced into the LAr detector through the circulating purification system. The light yield reaches 7.26$\pm$0.02 photonelectrons/keV for 41.5keV from $^{83m}Kr$ and 7.66$\pm$0.01 photonelectrons/keV for the 511keV from $^{22}Na$, as a comparison. The light yield varies with the drift electric field from 50 to 200V/cm have been also reported. After stopping fill, the decay rate of $^{83m}Kr$ with a fitted half-life of 1.83$\pm$0.11 h, which is consistent with the reported value of 1.83$\pm$0.02 h.

physics.ins-det

Neutron Beam Tests of Barium Fluoride Crystal for Dark Matter Direct Detection

In order to test the capabilities of Barium Fluoride (BaF2) Crystal for dark matter direct detection, nuclear recoils are studied with mono-energetic neutron beam. The energy spectra of nuclear recoils, quenching factors for elastic scattering neutrons and discrimination capability between neutron inelastic scattering events and γ events are obtained for various recoil energies of the F content in BaF2.

physics.ins-det

Neutron Beam Tests of $CsI(Na)$ and $CaF_{2}(Eu)$ Crystals for Dark Matter Direct Search

In recent decades, inorganic crystals have been widely used in dark matter direct search experiments. To contribute to the understanding of the capabilities of $CsI(Na)$ and $CaF_{2}(Eu)$ crystals, a mono-energetic neutron beam is utilized to study the properties of nuclear recoils, which are expected to be similar to signals of dark matter direct detection. The quenching factor of nuclear recoils in $CsI(Na)$ and $CaF_{2}(Eu)$, as well as an improved discrimination factor between nuclear recoils and $γ$ backgrounds in $CsI(Na)$, are reported.

physics.ins-det

Waterproofed Photomultiplier Tube Assemblies for the Daya Bay Reactor Neutrino Experiment

In the Daya Bay Reactor Neutrino Experiment 960 20-cm-diameter waterproof photomultiplier tubes are used to instrument three water pools as Cherenkov detectors for detecting cosmic-ray muons. Of these 960 photomultiplier tubes, 341 are recycled from the MACRO experiment. A systematic program was undertaken to refurbish them as waterproof assemblies. In the context of passing the water leakage check, a success rate better than 97% was achieved. Details of the design, fabrication, testing, operation, and performance of these waterproofed photomultiplier-tube assemblies are presented.

physics.ins-det