FlowMoDE: Coarse-to-fine Flow Matching for Detail-aware Sim-to-Real Monocular Depth Estimation

Monocular depth estimation is a fundamental capability for 3D spatial perception in robotic and intelligent systems. While data-driven discriminative methods have achieved compelling performance for monocular depth estimation, generative approaches can reconstruct fine structural details with stronger generalization. However, most existing generative diffusion models suffer from low inference efficiency caused by multi-step sampling, whereas single-step diffusion models struggle to recover high-fidelity depth maps. To mitigate these drawbacks, this paper presents FlowMoDE, a coarse-to-fine flow-matching-based framework for efficient, structure-aware monocular depth estimation supporting sim-to-real and cross-scene generalization. The core architecture first conducts coarse-level decoding conditioned on diffused features extracted from a pre-trained semantic encoder, and subsequently restores fine-grained structural patterns via expanded decoding layers. Trained exclusively on a single synthetic indoor dataset, our proposed method outperforms prior methods across five real-world indoor and outdoor datasets, yielding an average 14.1% reduction in relative error against state-of-the-art works as well as 9.9\% reduction in chamfer distance for point cloud reconstruction. We further validate the generalization capability of FlowMoDE on realistic robotic scenes, with qualitative comparisons against state-of-the-art methods. The project page is https://flowmode-shao.netlify.app/

cs.CV↗

EBV-CAN: Vision--Language Grounding for Contact-Aided Endoscope Navigation

Flexible endoscopes exploit structural compliance to traverse narrow lumens, pipes, and cavities, where navigation involves distributed environmental contact. This compliance makes tip motion depend on the evolving support configuration. We present external bird's-eye-view contact-aided navigation (EBV-CAN), a vision-language policy that combines one initial global static bird's-eye image with evolving endoscopic observations and motor state. Three supervised semantic queries locate the tip, next waypoint, and instructed target on the cached global image; their residual representations predict bending and insertion commands. We introduce the Vision-Language Contact-Aided (VLCA) dataset, linking 517 demonstrations and 75k action samples to 958k spatial entries and 93k remaining-route records. On 50 held-out episodes, tip-coordinate and waypoint localization reach 97.5% and 94.8%. Swapping the target instruction under identical observations changes target attention and motor output across 17 dual-target episodes. Across 1,920 physical trials of eight policies trained under a shared protocol, EBV-CAN achieves 183/240 successes (76.25%) under automatic blue-area scoring. Gated recurrent unit behavior cloning (GRU-BC) achieves the lowest matched-task offline mean absolute error (MAE), 0.056, and 1/240 physical successes, establishing distinct rankings for action imitation and task completion. Successful multi-guide executions and representative failures connect spatial progress, steering transitions, and visibility to physical navigation.

cs.RO↗

SurgCast: Action-Conditioned Future Skeletons for Controllable Surgical World Models

Surgical world models must turn prospective robot actions into visually faithful, structurally consistent instrument motion. We introduce SurgCast, which predicts future instrument skeletons from current structure, robot state, and future actions, then uses the forecast to control video generation. Dual-path injection combines skeleton geometry with derived, instrument-specific motion descriptors through geometric residuals and conditioning modulation. Both paths complement native action conditioning and are retained in a four-step causal student. On SutureBot and SRTH-Porcine-Cholei, the teacher and student improve all seven reported quality and instrument-consistency metrics over their respective direct-action baselines; teacher FVD decreases by 37.6% and 67.3%. Ablations show that future actions improve skeleton prediction and that combining both injection paths performs best across all six metrics under predicted skeletons. These results support using predicted articulated structure and its motion semantics as a control interface for surgical video prediction. Project videos and examples are available at https://surgcast.netlify.app/.

cs.CV↗

EndoLIFT: Language-Disambiguated Latent-Conditioned Rectified Flow for Bidirectional Endoscopic Control

Routine gastrointestinal endoscopy is intrinsically bidirectional: the instrument is advanced to reach target anatomy and later withdrawn or retroflexed for inspection, while an external cue may require earlier reversal. When the requested phase changes before the visual scene does, nearly identical observations can require opposite axial actions. We identify and formalize this ambiguity in bidirectional endoscopic control as intent aliasing. We propose EndoLIFT (Endoscopic Language-Instruction Flow with Trajectory Latents), a vision-language-action policy that combines explicit language-based intent conditioning with a latent-conditioned rectified-flow action expert. The policy receives RGB, a language instruction, and the previous-action state; a 32-D variational trajectory latent stochastically conditions continuous action-chunk generation. Controlled same-observation instruction swaps establish that language selects the axial mode, independently of whether the trajectory latent is present. Relative to the matched model without latent conditioning, EndoLIFT improves navigation-direction accuracy by 11.1 percentage points and reduces wrong-direction advance by 83\%. An architecture-controlled 1-bit mode-flag reference exhibits weaker canonical-anchor switching, while EndoLIFT retains 82.8\% intent-following accuracy across 44 held-out linguistic variants. In closed-loop evaluation, EndoLIFT improves overall success by 30 percentage points over EndoLIFT w/o VTL on both the seen colon phantom and the unseen lung and stomach phantoms, and completes 10/10 ex-vivo porcine-trachea trials. These results separate language-based intent selection from the trajectory latent's contribution to directional correctness and robust retraction.

cs.RO↗

Trajectory Divergence Horizon Decision for Reliable Dual-Arm Surgical Subtask Manipulation

Surgical robotic systems are increasingly being adopted as clinical workload rises, motivating autonomous solutions for repetitive manipulation subtasks. Learning-based controllers improve generalization compared with rule-based and analytic approaches, but most are trained for individual tasks and remain difficult to reuse across procedures. Vision-Language-Action (VLA) models provide a unified framework that integrates visual perception, language grounding, and action generation, offering a promising path toward more composable surgical autonomy. However, existing VLA policies rely on fixed-length open-loop action sequences, where changing scene conditions can lead to accumulated errors and potential risks in surgical manipulation. To mitigate this issue, we formulate surgical VLA deployment as an adaptive execution-horizon decision problem and propose Trajectory Divergence Horizon Decision (TDHD), a test-time mechanism that estimates step-wise action reliability by measuring the divergence between two flow-matching-generated trajectories under small noise perturbations and truncates execution using a dual-threshold rule to trigger timely replanning. We further establish a real-world da Vinci-like dual-arm benchmark with synchronized multi-view perception and language instructions, and collect 600 teleoperated demonstrations across needle (reach, pick, regrasp) and tissue (reach, lift, resection) manipulation suites. On real hardware with 20 trials per task setting, TDHD consistently improves performance over the latest VLA baselines: success increases from 55\% to 60\% for needle manipulation and from 55\% to 80\% for tissue manipulation, with the largest gains observed in the final manipulation stages. These results highlight the importance of adaptive execution control for reliable deployment of VLA models in surgical robotic manipulation.

cs.RO↗

CrossScope: A Role-Asymmetric World Model for Joint Dual-Scope Surgical Video Prediction

Visual world models typically learn future dynamics from a single observation stream, limiting their ability to model cooperative systems with multiple independently moving observers. We investigate this challenge in Mother--Child endoscopic retrograde cholangiopancreatography (ERCP), where two flexible scopes provide complementary yet role-dependent views without a calibrated stereo relationship. Unlike conventional multi-view fusion that assumes symmetric information exchange, we formulate \textbf{role-asymmetric dual-scope future prediction}, where cross-view evidence is selectively transferred according to the prediction target and its underlying spatial requirements. We propose \textbf{CrossScope}, a dual-stream surgical world model that preserves view-specific experts while enabling target-specific evidence routing through geometry-guided residual interactions. CrossScope learns two complementary communication directions: geometric motion cues from the Mother view guide Child-view future dynamics, while pose-aligned Child appearance supports Mother-view prediction only when valid spatial correspondence is established. This design allows each scope to contribute task-relevant evidence without compromising its view-specific representation. To evaluate this problem, we establish a paired dual-scope benchmark comprising synchronized phantom and real-world ERCP episodes, with evaluations assessing visual fidelity, structural preservation, target localization, and motion consistency. Experiments demonstrate that CrossScope consistently outperforms strong surgical video generation baselines, validating the importance of role-aware evidence routing for multi-observer visual world modeling.

cs.CV↗

EndoWAM: A Grounded World-Action Model for Generalizable Endoscopic Navigation

Autonomous endoscopic navigation can reduce clinicians' operational burden, yet robust control remains challenging due to tissue deformation, transient occlusions, and rapidly changing viewpoints. Existing learning-based policies typically predict actions from current observations without explicitly modeling future dynamics, limiting their robustness and reliability in safety-critical settings. World Action Models (WAMs) offer a promising alternative by coupling predictive visual dynamics with action generation, but extending them to robotic endoscopy remains challenging due to limited training data, restricted viewpoint diversity, deformable anatomy, and high inference latency. We present EndoWAM, which is, to our knowledge, the first WAM for generalizable robotic endoscopic navigation. EndoWAM introduces future grounding, which predicts task-relevant target regions in future observations from intermediate denoising features of a video world model. Specifically, EndoWAM couples a lightweight diffusion transformer for future target-region prediction with a discrete action expert through a shared predictive representation. This design injects target-aware supervision into predictive dynamics modeling, improving robustness to visual degradation and viewpoint changes while enabling real-time control in a single denoising pass. We further introduce EndoMotion, a robotic endoscopic motion dataset spanning three anatomically distinct procedures: ureteroscopy, esophagoscopy, and endoscopic retrograde cholangiopancreatography (ERCP). EndoWAM consistently outperforms all baselines and alternative grounding strategies, while demonstrating strong zero-shot generalization to unseen viewpoints, environments, and targets. These results establish EndoWAM as a predictive, target-grounded framework for accurate, generalizable, and long-horizon navigation in visually constrained endoscopic environments.

cs.RO↗

BiliVLA: Scene-Aware Vision-Language-Action Model with Reinforcement Learning for Autonomous Biliary Endoscopic Navigation

Endoscopic retrograde cholangiopancreatography (ERCP) demands precise endoscopic navigation and stable biliary cannulation within a narrow monocular field characterized by specular reflections, partial occlusions, and frequent tissue contact. Although recent robotic systems and vision-based assistance techniques improve operator ergonomics and provide perceptual cues, their performance degrades under pronounced anatomical variability and safety-critical visual artifacts, which hinders reliable autonomy in cannulation-grade procedures. Here, we present BiliVLA, a scene-aware Vision-Language-Action (VLA) framework that formulates biliary endoscopic navigation as an instruction-conditioned visuomotor learning problem. Given an endoscopic observation and a stage-specific language instruction, BiliVLA jointly predicts the target category, a grounded bounding box, and a discrete three-degree-of-freedom (3-DoF) motor command for a continuum endoscope. The proposed framework incorporates scene-aware supervision to improve semantic target consistency and safety-aware recovery supervision to induce conservative retreat behaviors under luminal wall contact. A key component of BiliVLA is a two-stage training paradigm that combines grounding-enhanced supervised fine-tuning (SFT) with Group Relative Policy Optimization (GRPO), thereby improving action reliability and decision consistency during closed-loop navigation. Across three ERCP subtasks, BiliVLA achieves the best overall performance in physical phantom experiments, with a total mIoU of 0.9625, an overall action precision of 91.96\%, and an overall success rate (SR) of 84.85\%. These results indicate that integrating semantic grounding, scene-aware learning, and reward-guided optimization strengthens perception--action alignment and enables more robust autonomous biliary endoscopic navigation.