Searcharxiv⌕ Search

arXiv subjects

Jitindra Fartiyal

Publications and source records attributed to Jitindra Fartiyal.

3 recordsLinked to original sources

OICycle: Observe, Infer, and Intervene Cycle for Belief-State Learning in Longitudinal Clinical Decision Making

Clinical care is a closed loop: clinicians observe partial evidence, infer the patient's state, and intervene, and each intervention determines what is observed next. This makes clinical decision making a partially observable Markov decision process (POMDP), in which a belief over a latent patient state must be updated from irregular, multimodal, and incomplete records. Yet most deep clinical models predict from a single snapshot or from coarsely aggregated history, while POMDP-based clinical methods need hand-specified discrete state spaces and transition models that real electronic health records cannot supply. We introduce OICycle (Observe, Infer, and Intervene Cycle), which learns a stochastic belief state directly from retrospective trajectories. At every episode, a learned recurrent operator fuses a sample of the previous belief with the new multimodal observations and the intervention that produced them. The resulting Gaussian belief is trained to predict clinicians' next interventions, the time to the next episode, and next-episode mortality. To enable reproducible evaluation, we release a benchmark derived from MIMIC-IV, MIMIC-IV-Note, and MIMIC-CXR that organizes 72,075 hospital admissions (5.4M laboratory, microbiology, radiology, prescription, and note records) into temporally ordered therapeutic--diagnostic episodes. Compared with an otherwise identical history-free model, OICycle improves next-intervention adaptive recall from 0.253 to 0.347, time-to-next-episode macro-F1 from 0.293 to 0.351, and next-episode mortality macro-F1 from 0.585 to 0.649. Analysis shows that the learned belief encodes intervention type and trajectory position and evolves smoothly across episodes, and that the benefit of history is concentrated in interventions whose ordering depends on prior findings.

cs.AI↗

PatchDenoiser: Parameter-efficient multi-scale patch learning and fusion denoiser for Low-dose CT imaging

Low-dose CT images are essential for reducing radiation exposure in cancer screening, pediatric imaging, and longitudinal monitoring protocols, but their quality is often degraded by noise from low-dose acquisition, patient motion, or scanner limitations, affecting both clinical interpretation and downstream analysis. Traditional filtering approaches often over-smooth and lose fine anatomical details, while deep learning methods, including CNNs, GANs, and transformers, may struggle to preserve such details or require large, computationally expensive models, limiting clinical practicality. We propose PatchDenoiser, a lightweight, energy-efficient multi-scale patch-based denoising framework. It decomposes denoising into local texture extraction and global context aggregation, fused via a spatially aware patch fusion strategy. This design enables effective noise suppression while preserving fine structural and anatomical details. PatchDenoiser is ultra-lightweight, with far fewer parameters and lower computational complexity than CNN, GAN, and transformer based denoisers. On the 2016 Mayo Low-Dose CT dataset, PatchDenoiser consistently outperforms state-of-the-art CNN- and GAN-based methods in PSNR and SSIM. It is robust to variations in slice thickness, reconstruction kernels, and HU windows, generalizes across scanners without fine-tuning, and reduces parameters by ~9x and energy consumption per inference by ~27x compared with conventional CNN denoisers. PatchDenoiser thus provides a practical, scalable, and computationally efficient solution for medical image denoising, balancing performance, robustness, and clinical deployability.

cs.CV↗

Dual Path Learning -- learning from noise and context for medical image denoising

Medical imaging plays a critical role in modern healthcare, enabling clinicians to accurately diagnose diseases and develop effective treatment plans. However, noise, often introduced by imaging devices, can degrade image quality, leading to misinterpretation and compromised clinical outcomes. Existing denoising approaches typically rely either on noise characteristics or on contextual information from the image. Moreover, they are commonly developed and evaluated for a single imaging modality and noise type. Motivated by Geng et.al CNCL, which integrates both noise and context, this study introduces a Dual-Pathway Learning (DPL) model architecture that effectively denoises medical images by leveraging both sources of information and fusing them to generate the final output. DPL is evaluated across multiple imaging modalities and various types of noise, demonstrating its robustness and generalizability. DPL improves PSNR by 3.35% compared to the baseline UNet when evaluated on Gaussian noise and trained across all modalities. The code is available at 10.5281/zenodo.15836053.

eess.IV↗