Publications and source records attributed to Jixing Zhang.

9 recordsLinked to original sources

Human Cardiac Measurements with Diamond Magnetometers

We demonstrate direct, non-invasive and non-contact detection of human cardiac magnetic signals using quantum sensors based on nitrogen-vacancy (NV) centers in diamond. Three configurations were employed recording magnetocardiography (MCG) signals in various shielded and unshielded environments. The signals were averaged over a few hundreds up to several thousands of heart beats to detect the MCG traces. The compact room-temperature NV sensors exhibit sensitivities of 6-26 pT/Hz^(1/2) with active sensing volumes below 0.5 mm^3, defining the performance level of the demonstrated MCG measurements. While the present signals are obtained by averaging, this performance already indicates a clear path toward single-shot MCG sensing. To move beyond shielded environments toward practical clinical use, strong noise suppression is required. To this end, we implement NV-based gradiometry and achieve efficient common-mode noise rejection, enabled by the intrinsically small sensing volume of NV sensors. Together, these multi-platform results obtained across diverse magnetic environments provide a solid foundation for translating quantum sensors into human medical diagnostics such as MCG and magnetoencephalography (MEG).

physics.med-ph

Near-limit quantum control beyond analytic tractability in many-body spin systems

As quantum control approaches hardware-imposed performance limits, weak effects omitted by reduced models become consequential. Assumptions required for analytic tractability then cease to guide control design and instead constrain further improvement. Here, we relax such assumptions and use simulation-guided stochastic tree search to navigate combinatorially large, discrete pulse-sequence spaces for robust many-body spin control. Experimentally, in a solid-state spin ensemble, the resulting computationally discovered pulse sequences substantially outperform analytically optimized baselines, despite being excluded by construction from analytic design criteria. Importantly, these unconventional sequences expose predictive structural features that enable rapid neural network--based performance evaluation. This efficiency gain makes the combinatorial scaling tractable and expands the control alphabet from 8 symmetry-restricted pulses to over 26,000 hardware-resolved options. The resulting fine-grained design freedom provides the control resolution required to reliably address weak, performance-limiting effects, unlocking qualitatively different spin-control capabilities beyond decades of traditional sequence design. Together, these results show that near performance limits, simplifying assumptions can become a primary constraint on quantum control in realistic hardware, and must be repurposed to guide computational discovery.

quant-ph

Deformation-Driven Enhancement of Spin Defect Emission in Hexagonal Boron Nitride

The negatively charged boron vacancy (VB-) in hexagonal boron nitride (hBN) has been extensively investigated as it offers a novel playground for two-dimensional quantum sensing, with ultimate proximity to target samples. However, its practical sensitivity is limited by the intrinsically weak photoluminescence of the spin ensemble. Here, we report a photoluminescence enhancement of up to 30 times from VB- centers in suspended regions of hBN compared to those in substrate-supported areas. The key spin properties, such as the optically detected magnetic resonance (ODMR) contrast and linewidth, as well as the spin lifetime, of the VB- centers in this region are well preserved. Detailed investigations, including measurements of zero-field ODMR, Raman spectroscopy, and Kelvin probe force microscopy, reveal a correlation between emission enhancement and local deformation in the sample. It is concluded that the suspended regions exhibit higher local deformation compared to the supported areas, breaking the local symmetry and thereby activating otherwise forbidden or weak optical transitions of the VB- centers.

quant-ph

Hybrid spin-phonon architecture for scalable solid-state quantum nodes

Solid-state spin systems hold great promise for quantum information processing and the construction of quantum networks. However, the considerable inhomogeneity of spins in solids poses a significant challenge to the scaling of solid-state quantum systems. A practical protocol to individually control and entangle spins remains elusive. To this end, we propose a hybrid spin-phonon architecture based on spin-embedded SiC optomechanical crystal (OMC) cavities, which integrates photonic and phononic channels allowing for interactions between multiple spins. With a Raman-facilitated process, the OMC cavities support coupling between the spin and the zero-point motion of the OMC cavity mode reaching 0.57 MHz, facilitating phonon preparation and spin Rabi swap processes. Based on this, we develop a spin-phonon interface that achieves a two-qubit controlled-Z gate with a simulated fidelity of $96.80\%$ and efficiently generates highly entangled Dicke states with over $99\%$ fidelity, by engineering the strongly coupled spin-phonon dark state which is robust against loss from excited state relaxation as well as spectral inhomogeneity of the defect centers. This provides a hybrid platform for exploring spin entanglement with potential scalability and full connectivity in addition to an optical link, and offers a pathway to investigate quantum acoustics in solid-state systems.

quant-ph

Blueprint for Diamond Magnetometry: Unraveling Quantum Dephasing of Nitrogen-Vacancy Center Ensembles in Diamond

Diamonds with nitrogen-vacancy (NV) center ensembles are one of the most promising solid-state quantum platforms for various sensing applications. The combination of a long spin dephasing time ($T_2^*$) and a high NV center concentration is crucial for pushing the sensitivity limits. In this work, we propose a systematic measurement approach to quantify the electron spin dephasing in NV center ensembles and analyze the contributions of various sources to the dephasing time, including NV-NV interactions, strain and electric field distributions, $^{13}$C nuclear spins, and P1 electron spins. Our method is validated using a series of high-performance diamond samples, providing a comprehensive understanding of dephasing mechanisms and revealing correlations between NV concentration and different dephasing sources. Based on these insights, we further evaluate and propose strategies to improve the achievable sensitivity limits for DC magnetic field measurements.

quant-ph

Efficient real-time spin readout of nitrogen-vacancy centers based on Bayesian estimation

In this work, to improve the spin readout efficiency of the nitrogen vacancy (NV) center, a real-time Bayesian estimation algorithm is proposed, which combines both the prior probability distribution and the fluorescence likelihood function established by the implementation of the NV center dynamics model. The theoretical surpass of the Cramer-Rao lower bound of the readout variance and the improvement of the readout efficiency in the simulation indicate that our approach is an appealing alternative to the conventional photon summation method. The Bayesian real-time estimation readout was experimentally realized by combining a high-performance acquisition and processing hardware, and the Rabi oscillation experiments divulged that the signal-to-noise ratio of our approach was improved by 28.6%. Therefore, it is anticipated that the employed Bayesian estimation readout will effectively present superior sensing capabilities of the NV ensemble, and foster the further development of compact and scalable quantum sensors and consequently novel quantum information processing devices on a monolithic platform.

quant-ph

Burst Eddy Current Testing with a Diamond Magnetometry

In this work, a burst eddy current testing technique based on the employment of a diamond nitrogen vacancy (NV) center magnetometer with the Hahn echo (HE) sequence is demonstrated. With the confocal experiment apparatus, the HE-based NV magnetometer attained a magnetic sensitivity of $4.3 ~ \mathrm{nT} / \sqrt{\mathrm{Hz}}$ and a volume-normalized sensitivity of $3.6 ~ \mathrm{pT} / \sqrt{\mathrm{Hz} \cdot \mathrm{mm}^{-3}}$, which are 5 times better than the already existing method under the same conditions. Based on the proposed magnetometer configuration, a burst eddy current (BEC) testing prototype achieves a minimum detectable sample smaller than ${300~μ \mathrm{m}}$ and measurement accuracy of $9.85~\mathrmμ \mathrm{m}$., which is employed to image different metallic specimens and detect the layered internal structures. Since our prototype comprises superb high sensitivity, it exhibits various potential applications in the fields of deformation monitoring, security screening, and quality control. Moreover, its biocompatibility and promising nanoscale resolution paves the way for electromagnetic testing in the fields of biomaterials.

physics.app-ph

A pulsed lock-in method for ensemble nitrogen-vacancy center magnetometry

This article proposes a scheme for nitrogen-vacancy (NV) center magnetometry that combines the advantages of lock-in detection and pulse-type scheme. The optimal conditions, optimal sensitivity, and noise-suppression capability of the proposed method are compared with those of the conventional methods from both theoretical and simulation points of view. Through experimental measurements, a four-time improvement in sensitivity and 60-times improvement in minimum resolvable magnetic field (MRMF) was obtained. By using a confocal experiment setup, proposed scheme achieves a sensitivity of 3 nT/Hz1/2 and a MRMF of 100 pT.

physics.app-ph

Diamond Nitrogen-Vacancy Center Magnetometry: Advances and Challenges

Diamond nitrogen-vacancy (NV) center magnetometry has recently received considerable interest from researchers in the fields of applied physics and sensors. The purpose of this review is to analyze the principle, sensitivity, technical development potential, and application prospect of the diamond NV center magnetometry. This review briefly introduces the physical characteristics of NV centers, summarizes basic principles of the NV center magnetometer, analyzes the theoretical sensitivity, and discusses the impact of technical noise on the NV center magnetometer. Furthermore, the most critical technologies that affect the performance of the NV center magnetometer are described: diamond sample preparation, microwave manipulation, fluorescence collection, and laser excitation. The theoretical and technical crucial problems, potential solutions and research technical route are discussed. In addition, this review discusses the influence of technical noise under the conventional technical conditions and the actual sensitivity which is determined by the theoretical sensitivity and the technical noise. It is envisaged that the sensitivity that can be achieved through an optimized design is in the order of 10 fT/Hz^1/2. Finally, the roadmap of applications of the diamond NV center magnetometer are presented.

physics.app-ph