Searcharxiv⌕ Search

arXiv subjects

Joao A. C. Lima

Publications and source records attributed to Joao A. C. Lima.

4 recordsLinked to original sources

Focus, Align, and Diffuse: Time-Series-Aware Keyframe Diffusion for Cardiac Dynamic Synthesis from Sparse Observations

Dense cardiac dynamics are essential for assessing cardiac function, yet in practice clinicians often observe only extremely sparse measurements. However, recovering full dynamics from such sparsity is a highly ill-posed problem due to the lack of temporal cues. While auxiliary time-series signals like ECG provide physiological guidance, effectively exploiting them is challenging due to the cross-modal representation gap and phase misalignment. In this work, we present CardioFAD, a Focus--Align--Diffuse paradigm that reformulates sparse cardiac dynamic synthesis as a recoverability--alignability anchor discovery problem. Our core insight is that resolving extreme temporal ambiguity requires a compact set of anchor states that are both sufficient to recover the visual trajectory and reliable for ECG--visual alignment. We therefore learn motion-salient keyframes under two complementary principles: trajectory sufficiency, which preserves trajectory-critical intra-modal motion content, and anchor alignment, which promotes consistent inter-modal correspondence at these anchors. We implement the Focus and Align modules optimized by the two aspects. Diffuse then performs two-stage generation by first synthesizing keyframes and subsequently interpolating the remaining frames. Extensive experiments on cardiac MRI and echocardiography videos demonstrate superior visual quality, temporal coherence, and improved functional consistency under the extreme one-shot regime.

eess.IV↗

Exploiting Completeness Perception with Diffusion Transformer for Unified 3D MRI Synthesis

Missing data problems, such as missing modalities in multi-modal brain MRI and missing slices in cardiac MRI, pose significant challenges in clinical practice. Existing methods rely on external guidance to supply detailed missing-state information for instructing generative models to synthesize missing MRIs. However, manual indicators are not always available or reliable in real-world scenarios due to the unpredictable nature of clinical environments. Moreover, these explicit masks are not informative enough to provide guidance for improving semantic consistency. In this work, we argue that generative models should infer and recognize missing states in a self-perceptive manner, enabling them to better capture subtle anatomical and pathological variations. Towards this goal, we propose CoPeDiT, a shared completeness-perception framework for 3D MRI synthesis, following a common conditioning strategy with task-specific instantiations for different missing-data scenarios. Specifically, we incorporate dedicated pretext tasks into our tokenizer, CoPeVAE, empowering it to learn completeness-aware discriminative prompt tokens, and design MDiT3D, a specialized diffusion transformer architecture for 3D MRI synthesis that effectively uses the completeness-aware prompt tokens as guidance to enhance semantic consistency in 3D space. Comprehensive evaluations on three large-scale MRI datasets demonstrate that CoPeDiT consistently improves upon state-of-the-art methods across diverse missing patterns, yielding high-fidelity and structurally consistent MRI synthesis. Our code is available at https://github.com/JK-Liu7/CoPeDiT.

eess.IV↗

Chain of Flow: ECG-Conditioned 4D Cardiac Cine Generation from Patient-Specific Anatomical Anchor

Cardiac cine magnetic resonance imaging (MRI) is central to functional cardiac assessment, yet a full current cine sequence may not always be directly available at the point of analysis. We introduce Chain of Flow (COF), an electrocardiography (ECG)-conditioned framework that combines patient-specific MRI and current ECG for subject-specific 4D cardiac cine generation. On the UK Biobank dataset, COF achieves strong image-level fidelity and downstream function-oriented performance on a shared same-visit evaluable benchmark. Multi-slice and multi-resolution analyses indicate stable structural generation quality across the short-axis stack and heterogeneous acquisition resolutions. Controlled phase-robustness analyses across resampled input MRI phases further provide same-visit proxy support for patient-specific MRI plus current ECG when a target MRI phase is not directly observed. A cross-visit route provides exploratory serial evidence, with the clearest gains in current-facing region-of-interest readout. Disease-category functional audits, case-level volume-trajectory evidence review further delineate where the current patient-specific MRI plus ECG formulation remains stable for anatomy-aware downstream cardiac analysis. Code is available at https://anonymous.4open.science/r/COF-paper-release-C88B.

cs.CV↗

Deep Learning-based Automated Aortic Area and Distensibility Assessment: The Multi-Ethnic Study of Atherosclerosis (MESA)

This study applies convolutional neural network (CNN)-based automatic segmentation and distensibility measurement of the ascending and descending aorta from 2D phase-contrast cine magnetic resonance imaging (PC-cine MRI) within the large MESA cohort with subsequent assessment on an external cohort of thoracic aortic aneurysm (TAA) patients. 2D PC-cine MRI images of the ascending and descending aorta at the pulmonary artery bifurcation from the MESA study were included. Train, validation, and internal test sets consisted of 1123 studies (24282 images), 374 studies (8067 images), and 375 studies (8069 images), respectively. An external test set of TAAs consisted of 37 studies (3224 images). A U-Net based CNN was constructed, and performance was evaluated utilizing dice coefficient (for segmentation) and concordance correlation coefficients (CCC) of aortic geometric parameters by comparing to manual segmentation and parameter estimation. Dice coefficients for aorta segmentation were 97.6% (CI: 97.5%-97.6%) and 93.6% (84.6%-96.7%) on the internal and external test of TAAs, respectively. CCC for comparison of manual and CNN maximum and minimum ascending aortic areas were 0.97 and 0.95, respectively, on the internal test set and 0.997 and 0.995, respectively, for the external test. CCCs for maximum and minimum descending aortic areas were 0.96 and 0. 98, respectively, on the internal test set and 0.93 and 0.93, respectively, on the external test set. We successfully developed and validated a U-Net based ascending and descending aortic segmentation and distensibility quantification model in a large multi-ethnic database and in an external cohort of TAA patients.

q-bio.QM↗