SearcharxivSearch

arXiv subjects

Jocelyn Monroe

Publications and source records attributed to Jocelyn Monroe.

15 recordsLinked to original sources

Physics Briefing Book: Input for the 2026 update of the European Strategy for Particle Physics

The European Strategy for Particle Physics (ESPP) reflects the vision and presents concrete plans of the European particle physics community for advancing human knowledge in fundamental physics. The ESPP is updated every five-to-six years through a community-driven process. It commences with the submission of specific proposals and other input from the community at large, outlining projects envisioned for the near-, mid-, and long-term future. All submitted contributions are evaluated by the Physics Preparatory Group (PPG), and a preliminary analysis is presented at a Symposium meant to foster a broad community discussion on the scientific value and feasibility of the various ideas proposed. The outcomes of the analysis and the deliberations at the Symposium are synthesized in the current Briefing Book, which provides an important input in the deliberations of the Strategy recommendations by the European Strategy Group (ESG).

hep-ex

Long nanomechanical resonators with circular cross-section

Fabrication of superconducting nanomechanical resonators for quantum research, detectors and devices traditionally relies on a lithographic process, resulting in oscillators with sharp edges and a suspended length limited to a few 100 micrometres. We report a low-investment top-down approach to fabricating NbTi nanowire resonators with suspended lengths up to several millimetres and diameters down to 100 nanometres. The nanowires possess high critical currents and fields, making them a natural choice for magnetomotive actuation and sensing. This fabrication technique is independent of the substrate material, dimensions and layout and can readily be adapted to fabricate nanowire resonators from any metal or alloy with suitable ductility and yield strength. Our work thus opens access to a new class of nanomechanical devices with applications including microscopic and mesoscopic investigations of quantum fluids, detecting dark matter and fundamental materials research in one-dimensional superconductors in vacuum.

physics.ins-det

Contextual Isotope Ranking Criteria for Peak Identification in Gamma Spectroscopy Using a Large Database

Isotope identification is a recurrent problem in gamma spectroscopy with high purity germanium detectors. In this work, new strategies are introduced to facilitate this type of analysis. Five criteria are used to identify the parent isotopes making a query on a large database of gamma-lines from a multitude of isotopes producing an output list whose entries are sorted so that the gamma-lines with the highest chance of being present in a sample are placed at the top. A metric to evaluate the performance of the different criteria is introduced and used to compare them. Two of the criteria are found to be superior than the others: one based on fuzzy logic, and another that makes use of the gamma relative emission probabilities. A program called histoGe implements these criteria using a SQLite database containing the gamma-lines of isotopes which was parsed from WWW Table of Radioactive Isotopes. histoGe is Free Software and is provided along with the database so they can be used to analyze spectra obtained with generic gamma-ray detectors.

physics.comp-ph

Feebly-Interacting Particles:FIPs 2020 Workshop Report

With the establishment and maturation of the experimental programs searching for new physics with sizeable couplings at the LHC, there is an increasing interest in the broader particle and astrophysics community for exploring the physics of light and feebly-interacting particles as a paradigm complementary to a New Physics sector at the TeV scale and beyond. FIPs 2020 has been the first workshop fully dedicated to the physics of feebly-interacting particles and was held virtually from 31 August to 4 September 2020. The workshop has gathered together experts from collider, beam dump, fixed target experiments, as well as from astrophysics, axions/ALPs searches, current/future neutrino experiments, and dark matter direct detection communities to discuss progress in experimental searches and underlying theory models for FIPs physics, and to enhance the cross-fertilisation across different fields. FIPs 2020 has been complemented by the topical workshop "Physics Beyond Colliders meets theory", held at CERN from 7 June to 9 June 2020. This document presents the summary of the talks presented at the workshops and the outcome of the subsequent discussions held immediately after. It aims to provide a clear picture of this blooming field and proposes a few recommendations for the next round of experimental results.

hep-ph

A High Pressure Time Projection Chamber with Optical Readout

Measurements of proton-nucleus scattering and high resolution neutrino-nucleus interaction imaging are key to reduce neutrino oscillation systematic uncertainties in future experiments. A High Pressure Time Projection Chamber (HPTPC) prototype has been constructed and operated at Royal Holloway University of London and CERN as a first step in the development of a HPTPC capable of performing these measurements as part of a future long-baseline neutrino oscillation experiment such as the Deep Underground Neutrino Experiment. In this paper we describe the design and operation of the prototype HPTPC with an argon based gas mixture. We report on the successful hybrid charge and optical readout, using four CCD cameras, of signals from Am-241 sources.

physics.ins-det

Dosimetry and calorimetry performance of a scientific CMOS camera for environmental monitoring

This paper explores the prospect of CMOS devices to assay lead in drinking water, using calorimetry. Lead occurs together with traces of radioisotopes, e.g. Lead-210, producing $\gamma$-emissions with energies ranging from 10 keV to several 100 keV when they decay; this range is detectable in silicon sensors. In this paper we test a CMOS camera (Oxford Instruments Neo 5.5) for its general performance as a detector of x-rays and low energy $\gamma$-rays and assess its sensitivity relative to the World Health Organization upper limit on lead in drinking water. Energies from 6 keV to 60 keV are examined. The CMOS camera has a linear energy response over this range and its energy resolution is for the most part slightly better than 2 %. The Neo sCMOS is not sensitive to x-rays with energies below $\sim\!\!10 keV$. The smallest detectable rate is 40$\pm$3 mHz, corresponding to an incident activity on the chip of 7$\pm$4 Bq. The estimation of the incident activity sensitivity from the detected activity relies on geometric acceptance and the measured efficiency vs. energy. We report the efficiency measurement, which is 0.08$\pm$0.02 % (0.0011$\pm$0.0002 %) at 26.3 keV (59.5 keV). Taking calorimetric information into account we measure a minimal detectable rate of 4$\pm$1 mHz (1.5$\pm$0.1 mHz) for 26.3 keV (59.5 keV) $\gamma$-rays, which corresponds to an incident activity of 1.0$\pm$0.6 Bq (57$\pm$33 Bq). Toy Monte Carlo and Geant4 simulations agree with these results. These results show this CMOS sensor is well-suited as a $\gamma$- and x-ray detector with sensitivity at the few to 100 ppb level for Lead-210 in a sample.

physics.ins-det

Triplet Lifetime in Gaseous Argon

MiniCLEAN is a single-phase liquid argon dark matter experiment. During the initial cooling phase, impurities within the cold gas ($<$140 K) were monitored by measuring the scintillation light triplet lifetime, and ultimately a triplet lifetime of 3.480 $\pm$ 0.001 (stat.) $\pm$ 0.064 (sys.) $μ$s was obtained, indicating ultra-pure argon. This is the longest argon triplet time constant ever reported. The effect of quenching of separate components of the scintillation light is also investigated.

physics.ins-det

Exploring the hidden interior of the Earth with directional neutrino measurements

Roughly 40% of the Earth's total heat flow is powered by radioactive decays in the crust and mantle. Geo-neutrinos produced by these decays provide important clues about the origin, formation and thermal evolution of our planet, as well as the composition of its interior. Previous measurements of geo-neutrinos have all relied on the detection of inverse beta decay reactions, which are insensitive to the contribution from potassium and do not provide model-independent information about the spatial distribution of geo-neutrino sources within the Earth. Here we present a method for measuring previously unresolved components of Earth's radiogenic heating using neutrino-electron elastic scattering and low-background, direction-sensitive tracking detectors. We calculate the exposures needed to probe various contributions to the total geo-neutrino flux, specifically those associated to potassium, the mantle and the core. The measurements proposed here chart a course for pioneering exploration of the veiled inner workings of the Earth.

physics.geo-ph

Index of refraction, Rayleigh scattering length, and Sellmeier coefficients in solid and liquid argon and xenon

Large liquid argon detectors have become widely used in low rate experiments, including dark matter and neutrino research. However, the optical properties of liquid argon are not well understood at the large scales relevant for current and near-future detectors.The index of refraction of liquid argon at the scin- tillation wavelength has not been measured, and current Rayleigh scattering length calculations disagree with measurements. Furthermore, the Rayleigh scattering length and index of refraction of solid argon and solid xenon at their scintillation wavelengths have not been previously measured or calculated. We introduce a new calculation using existing data in liquid and solid argon and xenon to extrapolate the optical properties at the scintillation wavelengths using the Sellmeier dispersion relationship.

physics.ins-det

Measurement of the directional sensitivity of DMTPC detectors

The Dark Matter Time Projection Chamber (DMTPC) is a direction-sensitive detector designed to measure the direction of recoiling $^{19}$F and $^{12}$C nuclei in low-pressure CF$_4$ gas using optical and charge readout systems. In this paper, we employ measurements from two DMTPC detectors, with operating pressures of 30-60 torr, to develop and validate a model of the directional response and performance of such detectors as a function of recoil energy. Using our model as a benchmark, we formulate the necessary specifications for a scalable directional detector with sensitivity comparable to that of current-generation counting (non-directional) experiments, which measure only recoil energy. Assuming the performance of existing DMTPC detectors, as well as current limits on the spin-dependent WIMP-nucleus cross section, we find that a 10-20 kg scale direction-sensitive detector is capable of correlating the measured direction of nuclear recoils with the predicted direction of incident dark matter particles and providing decisive (3$σ$) confirmation that a candidate signal from a non-directional experiment was indeed induced by elastic scattering of dark matter particles off of target nuclei.

astro-ph.IM

Directional Dark Matter Detection Beyond the Neutrino Bound

Coherent scattering of solar, atmospheric and diffuse supernovae neutrinos creates an irreducible background for direct dark matter experiments with sensitivities to WIMP-nucleon spin-independent scattering cross-sections of 10^(-46)-10^(-48) cm^2, depending on the WIMP mass. Even if one could eliminate all other backgrounds, this "neutrino floor" will limit future experiments with projected sensitivities to cross-sections as small as 10^(-48) cm^2. Direction-sensitive detectors have the potential to study dark matter beyond the neutrino bound by fitting event distributions in multiple dimensions: recoil kinetic energy, recoil track angle with respect to the sun, and event time. This work quantitatively explores the impact of direction-sensitivity on the neutrino bound in dark matter direct detection.

hep-ph

Design of the MiniCLEAN dark matter search veto detector subsystem

This paper describes the design of the active muon veto subsystem for the MiniCLEAN dark matter direct detection experiment at SNOLAB in Sudbury, Ontario, Canada. The water-filled veto is instrumented with 48 PMTs which are read out by front end electronics to time multiplex 48 photomultiplier channels into 6 digitizer channels and provide an instantaneous hit sum across the subsystem (N-Hit) for the veto trigger. We describe the primary system components: the PMTs, the support structure, the front-end electronics, and the data acquisition system.

physics.ins-det

Status and Prospects of the DMTPC Directional Dark Matter Experiment

The DMTPC directional dark matter detection experiment is a low-pressure CF4 gas time projection chamber, instrumented with charge and scintillation photon readout. This detector design strategy emphasizes reconstruction of WIMP-induced nuclear recoil tracks, in order to determine the direction of incident dark matter particles. Directional detection has the potential to make the definitive observation of dark matter using the unique angular signature of the dark matter wind, which is distinct from all known backgrounds. This talk will briefly review the experimental technique and current status of DMTPC.

physics.ins-det

The Maximum Patch Method for Directional Dark Matter Detection

Present and planned dark matter detection experiments search for WIMP-induced nuclear recoils in poorly known background conditions. In this environment, the maximum gap statistical method provides a way of setting more sensitive cross section upper limits by incorporating known signal information. We give a recipe for the numerical calculation of upper limits for planned directional dark matter detection experiments, that will measure both recoil energy and angle, based on the gaps between events in two-dimensional phase space.

astro-ph

Neutrino Backgrounds to Dark Matter Searches

Neutrino coherent scattering cross sections can be as large as 10^{-39} cm^2, while current dark matter experiments have sensitivities to WIMP coherent scattering cross sections five orders of magnitude smaller; future experiments plan to have sensitivities to cross sections as small as 10^{-48} cm^2. With large target masses and few keV recoil energy detection thresholds, neutral current coherent scattering of solar neutrinos becomes an irreducible background in dark matter searches. In the current zero-background analysis paradigm, neutrino coherent scattering will limit the achievable sensitivity to dark matter scattering cross sections, at the level of 10^{-46} cm^2.

astro-ph