Searcharxiv⌕ Search

arXiv subjects

Jocelyne Troccaz

Publications and source records attributed to Jocelyne Troccaz.

42 records · Page 3Linked to original sources

Intensity-Based Registration of Freehand 3D Ultrasound and CT-scan Images of the Kidney

This paper presents a method to register a pre-operative Computed-Tomography (CT) volume to a sparse set of intra-operative Ultra-Sound (US) slices. In the context of percutaneous renal puncture, the aim is to transfer planning information to an intra-operative coordinate system. The spatial position of the US slices is measured by optically localizing a calibrated probe. Assuming the reproducibility of kidney motion during breathing, and no deformation of the organ, the method consists in optimizing a rigid 6 Degree Of Freedom (DOF) transform by evaluating at each step the similarity between the set of US images and the CT volume. The correlation between CT and US images being naturally rather poor, the images have been preprocessed in order to increase their similarity. Among the similarity measures formerly studied in the context of medical image registration, Correlation Ratio (CR) turned out to be one of the most accurate and appropriate, particularly with the chosen non-derivative minimization scheme, namely Powell-Brent's. The resulting matching transforms are compared to a standard rigid surface registration involving segmentation, regarding both accuracy and repeatability. The obtained results are presented and discussed.

physics.med-ph↗

Aid to Percutaneous Renal Access by Virtual Projection of the Ultrasound Puncture Tract onto Fluoroscopic Images

Background and Purpose: Percutaneous renal access in the context of percutaneous nephrolithotomy (PCNL) is a difficult technique, requiring rapid and precise access to a particular calix. We present a computerized system designed to improve percutaneous renal access by projecting the ultrasound puncture tract onto fluoroscopic images. Materials and Methods: The system consists of a computer and a localizer allowing spatial localization of the position of the various instruments. Without any human intervention, the ultrasound nephrostomy tract is superimposed in real time onto fluoroscopic images acquired in various views. Results: We tested our approach by laboratory experiments on a phantom. Also, after approval by our institution's Ethics Committee, we validated this technique in the operating room during PCNL in one patient. Conclusion: Our system is reliable, and the absence of image-processing procedures makes it robust. We have initiated a prospective study to validate this technique both for PCNL specialists and as a learning tool.

physics.med-ph↗

Percutaneous renal puncture: requirements and preliminary results

This paper introduces the principles of computer assisted percutaneous renal puncture, that would provide the surgeon with an accurate pre-operative 3D planning on CT images and, after a rigid registration with space-localized echographic data, would help him to perform the puncture through an intuitive 2D/3D interface. The whole development stage relied on both CT and US images of a healthy subject. We carried out millimetric registrations on real data, then guidance experiments on a kidney phantom showed encouraging results.

physics.med-ph↗

Computer-aided hepatic tumour ablation

Surgical resection of hepatic tumours is not always possible. Alternative techniques consist in locally using chemical or physical agents to destroy the tumour and this may be performed percutaneously. It requires a precise localisation of the tumour placement during ablation. Computer-assisted surgery tools may be used in conjunction to these new ablation techniques to improve the therapeutic efficiency whilst benefiting from minimal invasiveness. This communication introduces the principles of a system for computer-assisted hepatic tumour ablation.

physics.med-ph↗

Rigid Registration of Freehand 3D Ultrasound and CT-Scan Kidney Images

This paper presents a method to register a preoperative CT volume to a sparse set of intraoperative US slices. In the context of percutaneous renal puncture, the aim is to transfer a planning information to an intraoperative coordinate system. The spatial position of the US slices is measured by localizing a calibrated probe. Our method consists in optimizing a rigid 6 degree of freedom (DOF) transform by evaluating at each step the similarity between the set of US images and the CT volume. The images have been preprocessed in order to increase the relationship between CT and US pixels. Correlation Ratio turned out to be the most accurate and appropriate similarity measure to be used in a Powell-Brent minimization scheme. Results are compared to a standard rigid point-to-point registration involving segmentation, and discussed.

physics.med-ph↗

Computer-aided hepatic tumour ablation : requirements and preliminary results

Surgical resection of hepatic tumours is not always possible, since it depends on different factors, among which their location inside the liver functional segments. Alternative techniques consist in local use of chemical or physical agents to destroy the tumour. Radio frequency and cryosurgical ablations are examples of such alternative techniques that may be performed percutaneously. This requires a precise localisation of the tumour placement during ablation. Computer-assisted surgery tools may be used in conjunction with these new ablation techniques to improve the therapeutic efficiency, whilst they benefit from minimal invasiveness. This paper introduces the principles of a system for computer-assisted hepatic tumour ablation and describes preliminary experiments focusing on data registration evaluation. To keep close to conventional protocols, we consider registration of pre-operative CT or MRI data to intra-operative echographic data.

physics.med-ph↗