SearcharxivSearch

arXiv subjects

Joe Bentley

Publications and source records attributed to Joe Bentley.

7 recordsLinked to original sources

Coherent feedback for quantum expander in gravitational wave observatories

The observation of gravitational waves from binary neutron star mergers offers insights into properties of extreme nuclear matter. However, their high-frequency signals in the kHz range are often masked by quantum noise of the laser light used. Here, we propose the "quantum expander with coherent feedback", a new detector design that features an additional optical cavity in the detector output and an internal squeeze operation. This approach allows to boost the sensitivity at high frequencies, at the same time providing a compact and tunable design for signal extraction. It allows to tailor the sensitivity of the detector to the specific signal frequency range. We demonstrate that our design allows to improve the sensitivity of the high-frequency detector concept NEMO (neutron star extreme matter observatory), increasing the detection rates by around 15%. Our approach promises new level of flexibility in designing the detectors aiming at high-frequency signals.

physics.ins-det

Designing optimal linear detectors -- a bottom-up approach

This paper develops a systematic approach to realising linear detectors with an optimised sensitivity, allowing for the detection of extremely weak signals. First, general constraints are derived on a specific class of input-output transfer functions of a linear detector. Then a physical realization of transfer functions in that class is found using the quantum network synthesis technique, which allows for the inference of the physical setup directly from the input-output transfer function. By exploring a minimal realization which has the minimum number of internal modes, it is shown that the optimal such detectors are internal squeezing schemes. Then, investigating non-minimal realizations, which is motivated by the parity-time symmetric systems, a quantum non-demolition measurement is systematically recovered.

quant-ph

Enhancing interferometer sensitivity without sacrificing bandwidth and stability: beyond single-mode and resolved-sideband approximation

Quantum noise limits the sensitivity of precision measurement devices, such as laser interferometer gravitational-wave observatories and axion detectors. In the shot-noise-limited regime, these resonant detectors are subject to a trade-off between the peak sensitivity and bandwidth. One approach to circumvent this limitation in gravitational-wave detectors is to embed an anomalous-dispersion optomechanical filter to broaden the bandwidth. The original filter cavity design, however, makes the entire system unstable. Recently, we proposed the coherent feedback between the arm cavity and the optomechanical filter to eliminate the instability via PT-symmetry. The original analysis based upon the Hamiltonian formalism adopted the single-mode and resolved-sideband approximations. In this paper, we go beyond these approximations and consider realistic parameters. We show that the main conclusion concerning stability remains intact, with both Nyquist analysis and a detailed time-domain simulation.

quant-ph

Direct approach to realising quantum filters for high-precision measurements

Quantum noise sets a fundamental limit to the sensitivity of high-precision measurements. Suppressing it can be achieved by using non-classical states and quantum filters, which modify both the noise and signal response. We find a novel approach to realising quantum filters directly from their frequency-domain transfer functions, utilising techniques developed by the quantum control community. It not only allows us to construct quantum filters that defy intuition, but also opens a path towards the systematic design of optimal quantum measurement devices. As an illustration, we show a new optical realisation of an active unstable filter with anomalous dispersion, proposed for improving the quantum-limited sensitivity of gravitational-wave detectors.

quant-ph

A Broadband Signal Recycling Scheme for Approaching the Quantum Limit from Optical Losses

Quantum noise limits the sensitivity of laser interferometric gravitational-wave detectors. Given the state-of-the-art optics, the optical losses define the lower bound of the best possible quantum-limited detector sensitivity. In this work, we come up with a broadband signal recycling scheme which gives potential solution to approaching this lower bound by converting the signal recycling cavity to be a broadband signal amplifier using an active optomechanical filter. We will show the difference and advantage of such a scheme compared with the previous white light cavity scheme using the optomechanical filter in [Phys.Rev.Lett.115.211104 (2015)]. The drawback is that the new scheme is more susceptible to the thermal noise of the mechanical oscillator.

gr-qc

Towards observing the neutron star collapse with gravitational wave detectors

Gravitational waves from binary neutron star inspirals have been detected along with the electromagnetic transients coming from the aftermath of the merger in GW170817. However, much is still unknown about the post-merger dynamics that connects these two sets of observables. This includes if, and when, the post-merger remnant star collapses to a black hole, and what are the necessary conditions to power a short gamma-ray burst, and other observed electromagnetic counterparts. Observing the collapse of the post-merger neutron star would shed led on these questions, constraining models for the short gamma-ray burst engine and the hot neutron star equation of state. In this work, we explore the scope of using gravitational wave detectors to measure the timing of the collapse either indirectly, by establishing the shut-off of the post-merger gravitational emission, or---more challengingly---directly, by detecting the collapse signal. For the indirect approach, we consider a kilohertz high-frequency detector design that utilises a previously studied coupled arm cavity and signal recycling cavity resonance. This design would give a signal-to-noise ratio of 0.5\,-\,8.6 (depending on the variation of waveform parameters) for a collapse gravitational wave signal occurring at 10\,ms post-merger of a binary at 50\,Mpc and with total mass $2.7 M_\odot$. For the direct approach, we propose a narrow-band detector design, utilising the sensitivity around the frequency of the arm cavity free spectral range. The proposed detector achieves a signal-to-noise ratio of 0.3\,-\,1.9, independent of the collapse time. This detector is limited by both the fundamental classical and quantum noise with the arm cavity power chosen as 10\,MW.

gr-qc

Converting the signal-recycling cavity into an unstable optomechanical filter to enhance the detection bandwidth of gravitational-wave detectors

Current and future interferometeric gravitational-wave detectors are limited predominantly by shot noise at high frequencies. Shot noise is reduced by introducing arm cavities and signal recycling, however, there exists a tradeoff between the peak sensitivity and bandwidth. This comes from the accumulated phase of signal sidebands when propagating inside the arm cavities. One idea is to cancel such a phase by introducing an unstable optomechanical filter. The original design proposed in [Phys.~Rev.~Lett.~{\bf 115},~211104 (2015)] requires an additional optomechanical filter coupled externally to the main interferometer. Here we consider a simplified design that converts the signal-recycling cavity itself into the unstable filter by using one mirror as a high-frequency mechanical oscillator and introducing an additional pump laser. However, the enhancement in bandwidth of this new design is less than the original design given the same set of optical parameters. The peak sensitivity improvement factor depends on the arm length, the signal-recycling cavity length, and the final detector bandwidth. For a 4~km interferometer, if the final detector bandwidth is around 2~kHz, with a 20~m signal-recycling cavity, the shot noise can be reduced by 10 decibels, in addition to the improvement introduced by squeezed light injection. We also find that the thermal noise of the mechanical oscillator is enhanced at low frequencies relative to the vacuum noise, while having a flat spectrum at high frequencies.

astro-ph.IM