Johannes Goupy

Publications and source records attributed to Johannes Goupy.

16 recordsLinked to original sources

Aluminum nuclear demagnetization refrigerator for powerful continuous cooling

Many laboratories routinely cool samples to 10 mK, but relatively few can cool condensed matter below 1 mK. Easy access to the microkelvin range would propel fields such as quantum sensors and quantum materials. Such temperatures are achieved with adiabatic nuclear demagnetization. Existing nuclear demagnetization refrigerators (NDR) are ``single-shot'', and the recycling time is incompatible with some sub-mK experiments. Furthermore, a high cooling power is required to overcome the excess heat load of order nW on NDR pre-cooled by cryogen-free dilution refrigerators. We report the performance of an aluminum NDR designed for powerful cooling when part of a dual stage continuous NDR (CNDR). Its thermal resistance is minimized to maximize the cycling rate of the CNDR and consequently its cooling power. At the same time, its susceptibility to eddy current heating is minimized. A CNDR based on two of the aluminum NDR presented here would achieve a cooling power of approximately 40 nW at 560 $μ$K less than six days after cooling from room temperature, with a small offset in electronic temperature that decreases as the time-dependent heat load decays.

physics.ins-det

CONCERTO: Instrument model of Fourier transform spectroscopy, white-noise components

Modern astrophysics relies on intricate instrument setups to meet the demands of sensitivity, sky coverage, and multi-channel observations. An example is the CONCERTO project, employing advanced technology like kinetic inductance detectors and a Martin-Puplett interferometer. This instrument, installed at the APEX telescope atop the Chajnantor plateau, began commissioning observations in April 2021. Following a successful commissioning phase that concluded in June 2021, CONCERTO was offered to the scientific community for observations, with a final observing run in December 2022. CONCERTO boasts an 18.5 arcmin field of view and a spectral resolution down to 1.45 GHz in the 130-310 GHz electromagnetic band. We developed a comprehensive instrument model of CONCERTO inspired by Fourier transform spectrometry principles to optimize performance and address systematic errors. This model integrates instrument noises, subsystem characteristics, and celestial signals, leveraging both physical data and simulations. Our methodology involves delineating simulation components, executing on-sky simulations, and comparing results with real observations. The resulting instrument model is pivotal, enabling a precise error correction and enhancing the reliability of astrophysical insights obtained from observational data. In this work, we focus on the description of three white-noise noise components included in the instrument model that characterize the white-noise level: the photon, the generation-recombination, and the amplifier noises.

astro-ph.IM

CONCERTO: instrument and status

CONCERTO (CarbON CII line in post-rEionization and ReionizaTiOn) is a low-resolution Fourier transform spectrometer dedicated to the study of star-forming galaxies and clusters of galaxies in the transparent millimeter windows from the ground. It is characterized by a wide instantaneous 18.6 arcmin field of view, operates at 130-310 GHz, and was installed on the 12-meter Atacama Pathfinder Experiment (APEX) telescope at 5100 m above sea level. CONCERTO's double focal planes host two arrays of 2152 kinetic inductance detectors and represent a pioneering instrument to meet a state-of-the-art scientific challenge. This paper introduces the CONCERTO instrument and explains its status, shows the first CONCERTO spectral maps of Orion, and describes the perspectives of the project.

astro-ph.IM

A millimetre-wave superconducting hyper-spectral device

Millimetre-wave observations represent an important tool for Cosmology studies. The Line Intensity Mapping (LIM) technique has been proposed to map in three dimensions the specific intensity due to line (e.g. [CII], CO) emission, for example from the primordial galaxies, as a function of redshift. Hyper-spectral integrated devices have the potential to replace the current Fourier transform, or the planned Fabry-Perot-based instruments operating at millimetre and sub-millimetre wavelengths. The aim is to perform hyper-spectral mapping, with a spectral resolution R= 100-1000, over large, i.e. thousands of beams, instantaneous patches of the Sky. The innovative integrated device that we have developed allows avoiding moving parts, complicated and/or dispersive optics or tunable filters to be operated at cryogenic temperatures. The prototype hyper-spectral focal plane is sensitive in the 75-90GHz range and contains nineteen horns for sixteen spectral-imaging channels, each selecting a frequency band of about 0.1GHz. For each channel a conical horn antenna, coupled to a planar superconducting resonant absorber made of thin aluminium, collects the radiation. A capacitively coupled titanium-aluminium bilayer Lumped Element Kinetic Inductance Detector (LEKID) is then in charge of dissipating and sensing the super-current established in the resonant absorber. The prototype is fabricated with only two photo-lithography steps over a commercial mono-crystalline sapphire substrate. It exhibits a spectral resolution of about 800. The optical noise equivalent power of the best channels is in the observational relevant 4E-17W/sqrt(Hz) range. The average sensitivity of all the channels is around 1E-16W/sqrt(Hz). The device, as expected from 3-D simulations, is polarisation-sensitive, paving the way to spectro-polarimetry measurements over very large instantaneous field-of-views.

astro-ph.IM

CONCERTO : Digital processing for finding and tuning LEKIDs

We describe the on-line algorithms developed to probe Lumped Element Kinetic Inductance Detectors (LEKID) in this paper. LEKIDs are millimeter wavelength detectors for astronomy. LEKID arrays are currently operated in different instruments as: NIKA2 at the IRAM telescope in Spain, KISS at the Teide Observatory telescope in Tenerife, and CONCERTO at the APEX 12-meter telescope in Chile. LEKIDs are superconducting microwave resonators able to detect the incoming light at millimeter wavelengths and they are well adapted for frequency multiplexing (currently up to 360 pixels on a single microwave guide). Nevertheless, their use for astronomical observations requires specific readout and acquisition systems both to deal with the instrumental and multiplexing complexity, and to adapt to the observational requirements (e.g. fast sampling rate, background variations, on-line calibration, photometric accuracy, etc). This paper presents the different steps of treatment from identifying the resonance frequency of each LEKID to the continuous automatic control of drifting LEKID resonance frequencies induced by background variations.

astro-ph.IM

A horn-coupled millimeter-wave on-chip spectrometer based on Lumped Element Kinetic Inductance Detectors

Context. Millimetre-wave astronomy is an important tool for both general astrophysics studies and cosmology. A large number of unidentified sources are being detected by the large field-of-view continuum instruments operating on large telescopes. Aims. New smart focal planes are needed to bridge the gap between large bandwidth continuum instruments operating on single dish telescopes and the high spectral and angular resolution interferometers (e.g. ALMA in Chile, NOEMA in France). The aim is to perform low-medium spectral resolution observations and select a lower number of potentially interesting sources, i.e. high-redshift galaxies, for further follow-up. Methods. We have designed, fabricated and tested an innovative on-chip spectrometer sensitive in the 85-110~GHz range. It contains sixteen channels selecting a frequency band of about 0.2 GHz each. A conical horn antenna coupled to a slot in the ground plane collects the radiation and guides it to a mm-wave microstrip transmission line placed on the other side of the mono-crystalline substrate. The mm-wave line is coupled to a filter-bank. Each filter is capacitively coupled to a Lumped Element Kinetic Inductance Detector (LEKID). The microstrip configuration allows to benefit from the high quality, i.e. low losses, mono-crystalline substrate, and at the same time prevents direct, i.e. un-filtered, LEKID illumination. Results. The prototype spectrometer exhibit a spectral resolution R = lambda / Delta_lambda = 300. The optical noise equivalent power is in the low 1E-16W/sqrt(Hz) range for an incoming power of about 0.2pW per channel. The device is polarisation-sensitive, with a cross-polarisation lower than 1% for the best channels.

astro-ph.IM

CONCERTO: a breakthrough in wide field-of-view spectroscopy at millimeter wavelengths

CarbON CII line in post-rEionization and ReionizaTiOn (CONCERTO) is a low-resolution spectrometer with an instantaneous field-of-view of 18.6 arcmin, operating in the 130-310 GHz transparent atmospheric window. It is installed on the 12-meter Atacama Pathfinder Experiment (APEX) telescope at 5100 m above sea level. The Fourier transform spectrometer (FTS) contains two focal planes hosting a total of 4304 kinetic inductance detectors. The FTS interferometric pattern is recorded on the fly while continuously scanning the sky. One of the goals of CONCERTO is to characterize the large-scale structure of the Universe by observing the integrated emission from unresolved galaxies. This methodology is an innovative technique and is called line intensity mapping. In this paper, we describe the CONCERTO instrument, the effect of the vibration of the FTS beamsplitter, and the status of the CONCERTO main survey.

astro-ph.IM

Superconducting aluminum heat switch with 3 n$Ω$ equivalent resistance

Superconducting heat switches with extremely low normal state resistances are needed for constructing continuous nuclear demagnetization refrigerators with high cooling power. Aluminum is a suitable superconductor for the heat switch because of its high Debye temperature and its commercial availability in high purity. We have constructed a high quality Al heat switch whose design is significantly different than that of previous heat switches. In order to join the Al to Cu with low contact resistance, we plasma etched the Al to remove its oxide layer then immediately deposited Au without breaking the vacuum of the e-beam evaporator. In the normal state of the heat switch, we measured a thermal conductance of $8 T$ W/K$^2$ which is equivalent to an electrical resistance of 3 n$Ω$ according to the Wiedemann-Franz law. In the superconducting state we measured a thermal conductance that is $2\times10^6$ times lower than that of the normal state at 50 mK.

physics.ins-det

Very low resistance Al/Cu joints for use at cryogenic temperatures

We present two different techniques for achieving low resistance ($<$20 n$\rm Ω$) contacts between copper and aluminium at cryogenic temperatures. The best method is based on gold plating of the surfaces in an e-beam evaporator immediately after Ar plasma etching in the same apparatus, yielding resistances as low as 3 n$\rm Ω$ that are stable over time. The second approach involves inserting indium in the Al/Cu joint. For both methods, we believe key elements are surface polishing, total removal of the aluminum oxide surface layer, and temporary application of large (typ. 11 kN) compression forces. We believe the values for gold plated contacts are the lowest ever reported for a Cu/Al joint of a few $\rm cm^{2}$. This technology could simplify the construction of thermal links for advanced cryogenics applications, in particular that of extremely low resistance heat switches for nuclear demagnetization refrigerators.

physics.ins-det

Contact-less phonon detection with massive cryogenic absorbers

We have developed a contact-less technique for the real time measurement of a-thermal (Cooper-pair breaking) phonons in an absorber held at sub-Kelvin temperatures. In particular, a thin-film aluminum superconducting resonator was realized on a 30-grams high-resistivity silicon crystal. The lumped-element resonator is inductively excited/read-out by a radio-frequency microstrip feed-line deposited on another wafer; the sensor, a Kinetic Inductance Detector (KID), is read-out without any physical contact or wiring to the absorber. The resonator demonstrates excellent electrical properties, particularly in terms of its internal quality factor. The detection of alphas and gammas in the massive absorber is achieved, with an RMS energy resolution of about 1.4 keV, which is already interesting for particle physics applications. The resolution of this prototype detector is mainly limited by the low (about 0.3%) conversion efficiency of deposited energy to superconducting excitations (quasi-particles). The demonstrated technique can be further optimized, and used to produce large arrays of a-thermal phonon detectors, for use in rare events searches such as: dark matter direct detection,neutrino-less double beta decay, or coherent elastic neutrino-nucleus scattering.

physics.ins-det

Interplay between kinetic inductance, non-linearity and quasiparticle dynamics in granular aluminum MKIDs

Microwave kinetic inductance detectors (MKIDs) are thin film, cryogenic, superconducting resonators. Incident Cooper pair-breaking radiation increases their kinetic inductance, thereby measurably lowering their resonant frequency. For a given resonant frequency, the highest MKID responsivity is obtained by maximizing the kinetic inductance fraction $α$. However, in circuits with $α$ close to unity, the low supercurrent density reduces the maximum number of readout photons before bifurcation due to self-Kerr non-linearity, therefore setting a bound for the maximum $α$ before the noise equivalent power (NEP) starts to increase. By fabricating granular aluminum MKIDs with different resistivities, we effectively sweep their kinetic inductance from tens to several hundreds of pH per square. We find a NEP minimum in the range of $25\; \text{aW}/\sqrt{\text{Hz}}$ at $α\approx 0.9$, which results from a tradeoff between the onset of non-linearity and a non-monotonic dependence of the noise spectral density vs. resistivity.

cond-mat.supr-con

Optical Response of Lumped-Element Kinetic-Inductance Detector Arrays

We present an analysis of the optical response of lumped-element kinetic-inductance detector arrays, based on the NIKA2 1mm array. This array has a dual-polarization sensitive Hilbert inductor for directly absorbing incident photons. We present the optical response calculated from a transmission line model, simulated with HFSS and measured using a Fourier transform spectrometer. We have estimated the energy absorbed by individual component of a pixel, such as the inductor. The difference between the absorption efficiencies is expected to be 20% from the simulations. The Fourier-transform spectroscopy measurement, performed on the actual NIKA2 arrays, validates our simulations. We discuss several possible ways to increase the absorption efficiency. This analysis can be used for optimization of the focal plane layout and can be extended to other kinetic inductance detector array designs in millimeter, sub-millimeter and terahertz frequency bands.

astro-ph.IM

Increased multiplexing of superconducting microresonator arrays by post-characterization adaptation of the on-chip capacitors

We present an interdigitated capacitor trimming technique for fine-tuning the resonance frequency of superconducting microresonators and increasing the multiplexing factor. We first measure the optical response of the array with a beam mapping system to link all resonances to their physical resonators. Then a new set of resonance frequencies with uniform spacing and higher multiplexing factor is designed. We use simulations to deduce the lengths that we should trim from the capacitor fingers in order to shift the resonances to the desired frequencies. The sample is then modified using contact lithography and re-measured using the same setup. We demonstrate this technique on a 112-pixel aluminum lumped-element kinetic-inductance detector array. Before trimming, the resonance frequency deviation of this array is investigated. The variation of the inductor width plays the main role for the deviation. After trimming, the mean fractional frequency error for identified resonators is -6.4e-4, with a standard deviation of 1.8e-4. The final optical yield is increased from 70.5% to 96.7% with no observable crosstalk beyond -15 dB during mapping. This technique could be applied to other photon-sensitive superconducting microresonator arrays for increasing the yield and multiplexing factor.

astro-ph.IM

Prototype high angular resolution LEKIDs for NIKA2

The current resolution of the NIKA2 260 GHz arrays is limited by the $1.6\times 1.5 mm^2$ inductor size on the individual pixels. In view of future updates of the instrument, we have developed a prototype array with smaller pixels that is experimentally compared to the current pixel design. We find an in-lab improvement increase of the angular resolution of 8%, promising an on-sky FWHM resolution of 10.2" using this new pixel design.

astro-ph.IM

The NIKA2 large field-of-view millimeter continuum camera for the 30-m IRAM telescope

Millimeter-wave continuum astronomy is today an indispensable tool for both general Astrophysics studies and Cosmology. General purpose, large field-of-view instruments are needed to map the sky at intermediate angular scales not accessible by the high-resolution interferometers and by the coarse angular resolution space-borne or ground-based surveys. These instruments have to be installed at the focal plane of the largest single-dish telescopes. In this context, we have constructed and deployed a multi-thousands pixels dual-band (150 and 260 GHz, respectively 2mm and 1.15mm wavelengths) camera to image an instantaneous field-of-view of 6.5arc-min and configurable to map the linear polarization at 260GHz. We are providing a detailed description of this instrument, named NIKA2 (New IRAM KID Arrays 2), in particular focusing on the cryogenics, the optics, the focal plane arrays based on Kinetic Inductance Detectors (KID) and the readout electronics. We are presenting the performance measured on the sky during the commissioning runs that took place between October 2015 and April 2017 at the 30-meter IRAM (Institut of Millimetric Radio Astronomy) telescope at Pico Veleta. NIKA2 has been successfully deployed and commissioned, performing in-line with the ambitious expectations. In particular, NIKA2 exhibits FWHM angular resolutions of around 11 and 17.5 arc-seconds at respectively 260 and 150GHz. The NEFD (Noise Equivalent Flux Densities) demonstrated on the maps are, at these two respective frequencies, 33 and 8 mJy*sqrt(s). A first successful science verification run has been achieved in April 2017. The instrument is currently offered to the astronomical community during the coming winter and will remain available for at least the next ten years.

astro-ph.IM

Lumped Element Kinetic Inductance Detectors for space applications

Kinetic Inductance Detectors (KID) are now routinely used in ground-based telescopes. Large arrays, deployed in formats up to kilopixels, exhibit state-of-the-art performance at millimeter (e.g. 120-300 GHz, NIKA and NIKA2 on the IRAM 30-meters) and sub-millimeter (e.g. 350-850 GHz AMKID on APEX) wavelengths. In view of future utilizations above the atmosphere, we have studied in detail the interaction of ionizing particles with LEKID (Lumped Element KID) arrays. We have constructed a dedicated cryogenic setup that allows to reproduce the typical observing conditions of a space-borne observatory. We will report the details and conclusions from a number of measurements. We give a brief description of our short term project, consisting in flying LEKID on a stratospheric balloon named B-SIDE.

astro-ph.IM