SearcharxivSearch

arXiv subjects

Johannes Greil

Publications and source records attributed to Johannes Greil.

7 recordsLinked to original sources

Design and Realization of Broadband Magnonic Spectrometers With Local Electrical Outputs

Microscopic radio-frequency (RF) devices based on propagating spin waves (SWs) are promising for compact, energy-efficient RF signal processing, but their implementation is impeded by fabrication complexity and the lack of efficient electrical readout. In this work, we demonstrate a SW-based Rowland circle spectrometer with electrical input and local electrical output transducers. The device is realized using a scalable fabrication process based on sputter deposition and wet-chemical etching of Yttrium-Iron-Garnet (YIG), forming concave grating structures with micrometer-scale features. The device functionality is confirmed by combined electrical and magneto-optical measurements, which show that the deflection of SW wavefronts at different input frequencies closely follows the analytically predicted behavior. The linear excitation of SWs via two input tones further confirms the spectrometer operation for simultaneously propagating waves. Beyond the single-device demonstration, we propose a concept for scalable architectures comprising multiple Rowland circles with tunable operating points. When combined with broadband parallel electrical readout, this approach enables control over bandwidth and spectral resolution, which are relevant to spectral occupancy detection in wireless communication systems.

physics.app-ph

Microscaled Tunable Magnonic RF Phase Shifters

Tunable, microscopic, and energy-efficient solutions for radio-frequency (RF) signal manipulation in the GHz regime are a key technology for efficient communication and sensing applications. Spin waves offer micrometer wavelengths at GHz frequencies, combined with strong magnetic-field tunability, making them inherently well-suited for tunable analog signal processing. Here, we demonstrate a novel concept: a micron-scale tunable RF phase shifter based on the wavelength shift of propagating spin waves. High energy efficiency is achieved by using the stray field of a micromagnet on a piezoelectrically actuated MEMS cantilever to locally induce this shift. The device shows a phase shift of more than 360{\deg} at a center frequency of 6.1 GHz using a phase-shifting area of less than 0.02mm$^2$. By changing the magnetic bias field, its functionality is experimentally confirmed over a range of center frequencies from 3 GHz to 8.2 GHz, and simulations show its applicability up to 14 GHz. A system-level characterization of an embedded device version demonstrates the qualification of magnonic phase shifters for highly integrated RF systems.

physics.app-ph

Characterizing the Linearity of Magnonic Devices for Radio-Frequency Applications

Magnonic devices exhibit strong amplitude-dependent nonlinearities, which are detrimental to signal integrity in radio-frequency (RF) signal processing applications. They also limit the power that such magnonic devices may process. In this paper we use micromagnetic simulations to characterize the nonlinearity of magnonic RF devices by investigating their intermodulation distortion (specifically third-order intermodulation products, IP$_3$ ). The IP$_3$ is a commonly used metric for RF components in communication systems and allows direct comparison with state-of-the-art electrical counterparts.

cond-mat.other

Establishing the Magnetoelastic Origin of Spin-Wave Routing through Focused Ion Beam Patterning

Spin waves are promising information carriers for analog and wave-based computing, where functionality relies on compact and precisely engineered scattering landscapes. Focused ion beam (FIB) irradiation enables such control by locally tailoring the spin-wave dispersion in yttrium iron garnet (YIG). However, a non-monotonic dependence of the spin-wave wavelength on increasing ion dose hinders predictive landscape design. Here, we present an experimentally validated framework that explains this non-monotonic spin-wave steering by linking phenomenological strain-induced anisotropy to its magnetoelastic origin. Irradiation-induced lattice dislocations drive elastic and plastic deformation, which evolve into partial amorphization, each stage contributing distinctly to the dispersion behavior. We combine post-irradiation wet-chemical etching and atomic force microscopy (AFM) to quantify thickness changes, and track the dispersion in etched regions using time-resolved magneto-optical Kerr effect (trMOKE) microscopy. Fitting the data to the Kalinikos--Slavin formalism with an added effective magnetoelastic field isolates contributions from elastic and plastic deformation. Validation is achieved by mapping the deformation evolution onto a three-phase scenario based on SRIM simulations, reproducing the extracted field trends, and by consistent strain tensor and micromagnetic analyses. These results establish a physical basis for FIB-engineered graded-index (GRIN) spin-wave landscapes and magnetoelastically programmable magnonic devices.

physics.app-ph

Design rules for low-insertion-loss magnonic transducers

We present a computational framework for the design of magnonic transducers, where waveguide antennas generate and pick up spin-wave signals. Our method relies on the combination of circuit-level models with micromagnetic simulations and allows simulation of complex geometries in the magnonic domain. We validated our model with experimental measurements, which showed good agreement witch the predicted scattering parameters of the system. Using our model we identified scaling rules of the antenna radiation resistance and we show strategies to maximize transduction efficiency between the electric and magnetic domains. We designed a transducer pair on YIG with 5dB insertion loss in a 100 MHz band, an unusually low value for micron-scale spin-wave devices. This demonstrates that magnonic devices can be very efficient and competitive in RF applications.

physics.app-ph

The Effect of Ga-Ion Irradiation on Sub-Micron-Wavelength Spin Waves in Yttrium-Iron-Garnet Films

We investigate the effect of focused-ion-beam (FIB) irradiation on spin waves with sub-micron wavelengths in Yttrium-Iron-Garnet (YIG) films. Time-resolved scanning transmission X-ray (TR-STXM) microscopy was used to image the spin waves in irradiated regions and deduce corresponding changes in the magnetic parameters of the film. We find that the changes of Ga$^+$ irradiation can be understood by assuming a few percent change in the effective magnetization $M_\mathrm{eff}$ of the film due to a trade-off between changes in anisotropy and effective film thickness. Our results demonstrate that FIB irradiation can be used to locally alter the dispersion relation and the effective refractive index $n_\textrm{eff}$ of the film, even for submicron wavelengths. To achieve the same change in $n_\textrm{eff}$ for shorter wavelengths, a higher dose is required, but no significant deterioration of spin wave propagation length in the irradiated regions was observed, even at the highest applied doses.

physics.app-ph

Secondary Excitation of Spin-Waves: How Electromagnetic Cross-Talk Impacts on Magnonic Devices

This work examines the impact of electromagnetic cross-talk in magnonic devices when using inductive spin-wave (SW) transducers. We present detailed electrical SW spectroscopy measurements showing the signal contributions to be considered in magnonic device design. We further provide a rule of thumb estimation for the cross-talk that is responsible for the secondary SW excitation at the output transducer. Simulations and calibrated electrical characterizations underpin this method. Additionally, we visualize the secondary SW excitation via time-resolved MOKE imaging in the forward-volume configuration in a 100nm Yttrium-Iron-Garnet (YIG) system. Our work is a step towards fast yet robust joint electromagentic-micromagnetic magnonic device design.

physics.app-ph