Searcharxiv⌕ Search

arXiv subjects

Johannes Hubmayr

Publications and source records attributed to Johannes Hubmayr.

At least 37 records · Page 2Linked to original sources

The Atacama Cosmology Telescope: A Measurement of the DR6 CMB Lensing Power Spectrum and its Implications for Structure Growth

We present new measurements of cosmic microwave background (CMB) lensing over $9400$ sq. deg. of the sky. These lensing measurements are derived from the Atacama Cosmology Telescope (ACT) Data Release 6 (DR6) CMB dataset, which consists of five seasons of ACT CMB temperature and polarization observations. We determine the amplitude of the CMB lensing power spectrum at $2.3\%$ precision ($43σ$ significance) using a novel pipeline that minimizes sensitivity to foregrounds and to noise properties. To ensure our results are robust, we analyze an extensive set of null tests, consistency tests, and systematic error estimates and employ a blinded analysis framework. The baseline spectrum is well fit by a lensing amplitude of $A_{\mathrm{lens}}=1.013\pm0.023$ relative to the Planck 2018 CMB power spectra best-fit $Λ$CDM model and $A_{\mathrm{lens}}=1.005\pm0.023$ relative to the $\text{ACT DR4} + \text{WMAP}$ best-fit model. From our lensing power spectrum measurement, we derive constraints on the parameter combination $S^{\mathrm{CMBL}}_8 \equiv σ_8 \left({Ω_m}/{0.3}\right)^{0.25}$ of $S^{\mathrm{CMBL}}_8= 0.818\pm0.022$ from ACT DR6 CMB lensing alone and $S^{\mathrm{CMBL}}_8= 0.813\pm0.018$ when combining ACT DR6 and Planck NPIPE CMB lensing power spectra. These results are in excellent agreement with $Λ$CDM model constraints from Planck or $\text{ACT DR4} + \text{WMAP}$ CMB power spectrum measurements. Our lensing measurements from redshifts $z\sim0.5$--$5$ are thus fully consistent with $Λ$CDM structure growth predictions based on CMB anisotropies probing primarily $z\sim1100$. We find no evidence for a suppression of the amplitude of cosmic structure at low redshifts

astro-ph.CO↗

Spectral Characterization of a 90 GHz CLASS Pixel

The Cosmology Large Angular Scale Surveyor (CLASS) is an experiment designed to measure the polarization of the cosmic microwave background on large angular scales to probe cosmic reionization and search for the inflationary $B$-mode signal. CLASS is a multi-frequency ensemble of telescopes with bands centered at 40, 90, 150, and 220 GHz. Each telescope has arrays of feedhorn-coupled transition edge sensor bolometers at the focal plane. The frequency response is primarily defined by the on-chip bandpass filter with additional contributions coming from the feedhorn, orthomode transducer, and 180-degree hybrid. In this study, we compare simulations and measurements of the frequency response of single pixel witness devices in the 90 GHz band with and without the bandpass filter. For the first time, we can separate the effects of the bandpass filter from the other microwave components using Fourier transform spectroscopy and design splits of the pixel. The results show that the -3 dB band edges are at 80 GHz and 108 GHz. The measurements demonstrate a robust method for characterizing the spectral response of individual components, which is crucial for optimizing the performance of future detector arrays.

astro-ph.IM↗

Thermal and Electrical Properties of Prototype Readout Components for CMB-S4

CMB-S4 is the fourth-generation ground-based cosmic microwave background project, designed to probe the early universe and cosmic inflation. CMB-S4 would achieve its science goals in part by dramatically increasing the number of transition edge sensor (TES) bolometer detectors on the sky. The detector readout system for CMB-S4 is time-division multiplexing (TDM) with a two-stage Superconducting Quantum Interference Device (SQUID) system. To accommodate the large increase in detectors, the size of our camera increases, placing physical constraints on the readout, its wiring, and its power dissipation. Therefore, to optimize readout performance, we need to balance competing design considerations such as thermal load and bandwidth. We present results characterizing the thermal and electrical performance of prototype components, including wiring and SQUID arrays for CMB-S4, and discuss the impact on overall system performance.

astro-ph.IM↗

Development of Silicon Micromachined Waveguide Filter-Banks for On-Chip Spectrometers

Development of high-speed, spatial-mapping spectrometers in the millimeter and far-infrared frequencies would enable entirely new research avenues in astronomy and cosmology. An "on-chip" spectrometer is one such technology that could enable Line Intensity Mapping. Recent work has shown the promise of high-speed imaging; however, a limiting factor is that many of these devices suffer from low optical efficiency. Here we present the fabrication of a metalized, Si waveguide filter-bank fabricated using deep reactive ion etching for use in millimeter spectroscopy. Our design simultaneously provides high-density pixel packing, high optical efficiency, high spectral resolution, and is readily compatible with simple and multiplexable MKID arrays. Gold plated test waveguide and filter show excellent match to simulations with a measured resolving power of 263 and a loss quality factor of 1116 at room temperature. The results show promise for extending the measurements to larger, multi-wavelength designs.

astro-ph.IM↗

The Simons Observatory: Characterization of All DC/RF Routing Wafers for Detector Modules

The Simons Observatory (SO) is a cosmic microwave background experiment with over 67,000 polarization-sensitive transition-edge sensor (TES) detectors currently installed for use in observations and plans to increase the total detector count to ${\sim}$98,000 detectors with the Advanced SO upgrade. The TES arrays are packaged into Universal Focal-Plane Modules (UFMs), which also contain the multiplexing readout circuit. Within a readout module, a DC/RF routing wafer provides a cold interface between the detectors and the readout multiplexing chips. Each routing wafer hosts twelve bias lines, which contain the ${\sim}$400 $μΩ$ shunt resistors that are part of the TES bias circuitry. More than 70 routing wafers have been fabricated and tested both at room temperature and 100 mK before integration into UFMs. The lab measurements for all screened wafers have been compiled to show the distribution of measured average shunt resistance Rsh for each bias line, both across bias lines on a single routing wafer and across all routing wafers. The mean average shunt resistance for all wafers was found to be 396 $μΩ$ with a standard deviation of 16 $μΩ$, or ${\sim}$4%. For each wafer, we note good uniformity of average Rsh between bias lines, with a slight downward trend with increasing distance from the center of the wafer. The fabrication data collected at room temperature shows agreement with the cryogenic measurements of Rsh distribution.

astro-ph.IM↗

CCAT: Mod-Cam Cryogenic Performance and its Impact on 280 GHz KID Array Noise

The CCAT Observatory's Fred Young Submillimeter Telescope (FYST) is designed to observe submillimeter astronomical signals with high precision, using receivers fielding state-of-the-art kinetic inductance detector (KID) arrays. Mod-Cam, a first-light instrument for FYST, serves as a testbed for instrument module characterization, including detailed evaluation of thermal behavior under operating conditions prior to deploying modules in the larger Prime-Cam instrument. Prime-Cam is a first generation multi-band, wide-field camera for FYST, designed to field up to seven instrument modules and provide unprecedented sensitivity across a broad frequency range. We present results from two key laboratory characterizations: an "optically open" cooldown to validate the overall thermal performance of the cryostat, and a "cold load" cooldown to measure the effect of focal plane temperature stability on detector noise. During the optically open test, we achieved stable base temperatures of 1.5 K on the 1 K stage and 85 mK at the detector stage. In the cold load configuration, we measured a detector focal plane RMS temperature stability of 3.2e-5 K. From this stability measurement, we demonstrate that the equivalent power from focal plane thermal fluctuations is only 0.0040% of a 5pW incident photon power for aluminum detectors and 0.0023% for titanium-nitride detectors, a negligible level for CCAT science goals. This highlights the success of the cryogenic system design and thermal management.

astro-ph.IM↗

The Atacama Cosmology Telescope: DR6 Power Spectra, Likelihoods and $Λ$CDM Parameters

We present power spectra of the cosmic microwave background (CMB) anisotropy in temperature and polarization, measured from the Data Release 6 maps made from Atacama Cosmology Telescope (ACT) data. These cover 19,000 deg$^2$ of sky in bands centered at 98, 150 and 220 GHz, with white noise levels three times lower than Planck in polarization. We find that the ACT angular power spectra estimated over 10,000 deg$^2$, and measured to arcminute scales in TT, TE and EE, are well fit by the sum of CMB and foregrounds, where the CMB spectra are described by the $Λ$CDM model. Combining ACT with larger-scale Planck data, the joint P-ACT dataset provides tight limits on the ingredients, expansion rate, and initial conditions of the universe. We find similar constraining power, and consistent results, from either the Planck power spectra or from ACT combined with WMAP data, as well as from either temperature or polarization in the joint P-ACT dataset. When combined with CMB lensing from ACT and Planck, and baryon acoustic oscillation data from DESI DR1, we measure a baryon density of $Ω_b h^2=0.0226\pm0.0001$, a cold dark matter density of $Ω_c h^2=0.118\pm0.001$, a Hubble constant of $H_0=68.22\pm0.36$ km/s/Mpc, a spectral index of $n_s=0.974\pm0.003$, and an amplitude of density fluctuations of $σ_8=0.813\pm0.005$. Including the DESI DR2 data tightens the Hubble constant to $H_0=68.43\pm0.27$ km/s/Mpc; $Λ$CDM parameters agree between the P-ACT and DESI DR2 data at the $1.6σ$ level. We find no evidence for excess lensing in the power spectrum, and no departure from spatial flatness. The contribution from Sunyaev-Zel'dovich (SZ) anisotropy is detected at high significance; we find evidence for a tilt with suppressed small-scale power compared to our baseline SZ template spectrum, consistent with hydrodynamical simulations with feedback.

astro-ph.CO↗

The Atacama Cosmology Telescope: DR6 Constraints on Extended Cosmological Models

We use new cosmic microwave background (CMB) primary temperature and polarization anisotropy measurements from the Atacama Cosmology Telescope (ACT) Data Release 6 (DR6) to test foundational assumptions of the standard cosmological model and set constraints on extensions to it. We derive constraints from the ACT DR6 power spectra alone, as well as in combination with legacy data from Planck. To break geometric degeneracies, we include ACT and Planck CMB lensing data and baryon acoustic oscillation data from DESI Year-1, and further add supernovae measurements from Pantheon+ for models that affect the late-time expansion history. We verify the near-scale-invariance (running of the spectral index $d n_s/d\ln k = 0.0062 \pm 0.0052$) and adiabaticity of the primordial perturbations. Neutrino properties are consistent with Standard Model predictions: we find no evidence for new light, relativistic species that are free-streaming ($N_{\rm eff} = 2.86 \pm 0.13$, which combined with external BBN data becomes $N_{\rm eff} = 2.89 \pm 0.11$), for non-zero neutrino masses ($\sum m_ν< 0.082$ eV at 95% CL), or for neutrino self-interactions. We also find no evidence for self-interacting dark radiation ($N_{\rm idr} < 0.134$), early-universe variation of fundamental constants, early dark energy, primordial magnetic fields, or modified recombination. Our data are consistent with standard BBN, the FIRAS-inferred CMB temperature, a dark matter component that is collisionless and with only a small fraction allowed as axion-like particles, a cosmological constant, and the late-time growth rate predicted by general relativity. We find no statistically significant preference for a departure from the baseline $Λ$CDM model. In general, models introduced to increase the Hubble constant or to decrease the amplitude of density fluctuations inferred from the primary CMB are not favored by our data.

astro-ph.CO↗

A Measurement of the Largest-Scale CMB E-mode Polarization with CLASS

We present measurements of large-scale cosmic microwave background (CMB) E-mode polarization from the Cosmology Large Angular Scale Surveyor (CLASS) 90 GHz data. Using 115 det-yr of observations collected through 2024 with a variable-delay polarization modulator, we achieved a polarization sensitivity of $78\,\mathrm{μK\,arcmin}$, comparable to Planck at similar frequencies (100 and 143 GHz). The analysis demonstrates effective mitigation of systematic errors and addresses challenges to large-angular-scale power recovery posed by time-domain filtering in maximum-likelihood map-making. A novel implementation of the pixel-space transfer matrix is introduced, which enables efficient filtering simulations and bias correction in the power spectrum using the quadratic cross-spectrum estimator. Overall, we achieved an unbiased time-domain filtering correction to recover the largest angular scale polarization, with the only power deficit, arising from map-making non-linearity, being characterized as less than $3\%$. Through cross-correlation with Planck, we detected the cosmic reionization at $99.4\%$ significance and measured the reionization optical depth $τ=0.053^{+0.018}_{-0.019}$, marking the first ground-based attempt at such a measurement. At intermediate angular scales ($\ell>30$), our results, both independently and in cross-correlation with Planck, remain fully consistent with Planck's measurements.

astro-ph.CO↗

The Atacama Cosmology Telescope: DR6 Maps

We present Atacama Cosmology Telescope (ACT) Data Release 6 (DR6) maps of the Cosmic Microwave Background temperature and polarization anisotropy at arcminute resolution over three frequency bands centered on 98, 150 and 220 GHz. The maps are based on data collected with the AdvancedACT camera over the period 2017--2022 and cover 19,000 square degrees with a median combined depth of 10 uK arcmin. We describe the instrument, mapmaking and map properties and illustrate them with a number of figures and tables. The ACT DR6 maps and derived products are available on LAMBDA at https://lambda.gsfc.nasa.gov/product/act/actadv_prod_table.html. We also provide an interactive web atlas at https://phy-act1.princeton.edu/public/snaess/actpol/dr6/atlas and HiPS data sets in Aladin (e.g. https://alasky.cds.unistra.fr/ACT/DR4DR6/color_CMB).

astro-ph.CO↗

Compact Superconducting Kinetic Inductance Traveling Wave Parametric Amplifiers with On-chip rf Components

Quantum computing systems and fundamental physics experiments using superconducting technologies frequently require signal amplification chains operating near the quantum limit of added noise. Both Josephson parametric amplifiers (JPAs) and traveling wave parametric amplifiers (TWPAs) have been used as first-stage amplifiers to enable readout chains operating within a few quanta or less of the quantum limit. These devices are also presently entering the commercial industry. However, nearly all demonstrations and existing products require bulky external microwave components for interconnection and application of requisite biases. These components -- cabling interconnects, bias tees, directional couplers, and diplexers -- increase the overall amplifier footprint, installation complexity, and reduce already limited available cryogenic volumes. Additionally, these components introduce loss and reflections which impact the measurement efficiency and readout system noise performance; thus making it more difficult to operate near the quantum limit. Here we present the design and validation of microfabricated bias tees and directional couplers for operating three-wave mixing kinetic inductance TWPAs (KITs). We report the performance of KITs integrated with the microfabricated rf components. Using these devices we demonstrate reduction in the amplifier installation footprint by a factor of nearly five and elimination of all external, lossy microwave components previously required to operate a KIT. Our device displays a 2.8 GHz 3 dB bandwidth with a median true gain of 17.5 dB and median system noise of 3.4 quanta. These efforts represent the first full integration of all rf components mandatory for TWPA operation on-chip. Our results mark significant progress towards the miniaturization and simplification of parametric amplifier setups and will aid in their more widespread applicability.

quant-ph↗

Simons Observatory: Characterization of the Large Aperture Telescope Receiver

The Simons Observatory (SO) is a ground-based cosmic microwave background (CMB) survey experiment that currently consists of three 0.42m small-aperture telescopes (SATs) and one 6m large-aperture telescope (LAT), located at an elevation of 5200m in the Atacama Desert in Chile. At the LAT's focal plane, SO will install >62,000 transition-edge sensor detectors across 13 optics tubes (OTs) within the Large Aperture Telescope Receiver (LATR), the largest cryogenic camera ever built to observe the CMB. Here we report on the validation of the LATR in the laboratory and the subsequent dark testing and validation within the LAT. We show that the LATR meets cryogenic, optical, and detector specifications required for high-sensitivity measurements of the CMB. At the time of writing, the LATR is installed in the LAT with six OTs (corresponding to >31,000 detectors), and the LAT mirrors and remaining seven OTs are undergoing development.

astro-ph.IM↗

CCAT: LED Mapping and Characterization of the 280 GHz TiN KID Array

Prime-Cam, one of the primary instruments for the Fred Young Submillimeter Telescope (FYST) developed by the CCAT Collaboration, will house up to seven instrument modules, with the first operating at 280 GHz. Each module will include three arrays of superconducting microwave kinetic inductance detectors (KIDs). The first KID array fabricated for the 280 GHz module uses titanium-nitride (TiN) as the superconducting material and has 3,456 individual detectors, while the other two arrays use aluminum. This paper presents the design and laboratory characterization of the 280 GHz TiN array, which is cooled below its critical temperature to ~0.1 K and read out over six RF feedlines. LED mapping, a technique for matching the measured resonant frequency of a detector to its physical position, was performed on the array so that the results can be used to lithographically trim the KID capacitors and increase the yield of the array by reducing frequency collisions. We present the methods and results of LED mapping the 280 GHz TiN KID array before deployment on FYST.

astro-ph.IM↗

Thermal architecture for a cryogenic super-pressure balloon payload: design and development of the Taurus flight cryostat

We describe the cryogenic system being developed for Taurus: a super-pressure balloon-borne microwave polarimeter scheduled to fly in 2027. The Taurus cryogenic system consists of a 660L liquid helium cryostat which achieves a base temperature of <100mK with the help of a capillary-fed superfluid tank and a closed cycle dilution refrigerator. The main tank is supported with fiberglass flexures and is encased in two layers of vapor-cooled shields which allow Taurus to make full use of the extended flight time offered by the super-pressure balloon platform. The Taurus cryostat is projected to hold for over 50 days while weighing under 1000lbs. We present the design, testing, and thermal analysis of the Taurus cryogenic systems.

physics.ins-det↗

Direct Imaging of Transition-Edge Sensors with Scanning SQUID Microscopy

Significant advancements have been made in understanding the physics of transition-edge sensors (TESs) over the past decade. However, key questions remain, particularly a detailed understanding of the current-dependent resistance of these detectors when biased within their superconducting transition. We use scanning superconducting quantum interference device (SQUID) microscopy (SSM) to image the local diamagnetic response of aluminum-manganese alloy (Al-Mn) transition-edge sensors (TESs) near their critical temperature of approximately 175 mK. By doing so, we gain insights into how the device dimensions influence TES transition width, which in turn affects device operation and informs optimal device design. Our images reveal that the Al-Mn thin film near the niobium (Nb) leads exhibits an excess diamagnetic response at temperatures several milli-Kelvin (mK) higher than the bulk of the film farther from the contacts. A possible origin of this behavior is a longitudinal proximity effect between the Nb and Al-Mn where the TES acts as a weak link between superconducting leads. We discuss how this effect shapes the temperature dependence of the resistance as the spacing between the leads decreases. This work demonstrates that magnetic imaging with SSM is a powerful tool for local characterization of superconducting detectors.

cond-mat.supr-con↗

Modeling optical systematics for the Taurus CMB experiment

We simulate a variety of optical systematics for Taurus, a balloon-borne cosmic microwave background (CMB) polarisation experiment, to assess their impact on large-scale E-mode polarisation measurements and constraints of the optical depth to reionisation τ. We model a one-month flight of Taurus from Wanaka, New Zealand aboard a super-pressure balloon (SPB). We simulate night-time scans of both the CMB and dust foregrounds in the 150GHz band, one of Taurus's four observing bands. We consider a variety of possible systematics that may affect Taurus's observations, including non-gaussian beams, pointing reconstruction error, and half-wave plate (HWP) non-idealities. For each of these, we evaluate the residual power in the difference between maps simulated with and without the systematic, and compare this to the expected signal level corresponding to Taurus's science goals. Our results indicate that most of the HWP-related systematics can be mitigated to be smaller than sample variance by calibrating with Planck's TT spectrum and using an achromatic HWP model, with a preference for five layers of sapphire to ensure good systematic control. However, additional beam characterization will be required to mitigate far-sidelobe pickup from dust on larger scales.

astro-ph.CO↗

Calibration Measurements of the BICEP3 and BICEP Array CMB Polarimeters from 2017 to 2024

The BICEP3 and BICEP Array polarimeters are small-aperture refracting telescopes located at the South Pole designed to measure primordial gravitational wave signatures in the Cosmic Microwave Background (CMB) polarization, predicted by inflation. Constraining the inflationary signal requires not only excellent sensitivity, but also careful control of instrumental systematics. Both instruments use antenna-coupled orthogonally polarized detector pairs, and the polarized sky signal is reconstructed by taking the difference in each detector pair. As a result, the differential response between detectors within a pair becomes an important systematic effect we must control. Additionally, mapping the intensity and polarization response in regions away from the main beam can inform how sidelobe levels affect CMB measurements. Extensive calibration measurements are taken in situ every austral summer for control of instrumental systematics and instrument characterisation. In this work, we detail the set of beam calibration measurements that we conduct on the BICEP receivers, from deep measurements of main beam response to polarized beam response and sidelobe mapping. We discuss the impact of these measurements for instrumental systematics studies and design choices for future CMB receivers.

astro-ph.CO↗

CCAT: Nonlinear effects in 280 GHz aluminum kinetic inductance detectors

Prime-Cam, a first-generation science instrument for the Atacama-based Fred Young Submillimeter Telescope, is being built by the CCAT Collaboration to observe at millimeter and submillimeter wavelengths using kinetic inductance detectors (KIDs). Prime-Cam's 280 GHz instrument module will deploy with two aluminum-based KID arrays and one titanium nitride-based KID array, totaling approximately 10,000 detectors at the focal plane, all of which have been fabricated and are currently undergoing testing. One complication of fielding large arrays of KIDs under dynamic loading conditions is tuning the detector tone powers to maximize signal-to-noise while avoiding bifurcation due to the nonlinear kinetic inductance. For aluminum-based KIDs, this is further complicated by additional nonlinear effects which couple tone power to resonator quality factors and resonant frequencies. While both nonequilibrium quasiparticle dynamics and two-level system fluctuations have been shown to give rise to qualitatively similar distortions, modeling these effects alongside nonlinear kinetic inductance is inefficient when fitting thousands of resonators on-sky with existing models. For this reason, it is necessary to have a detailed understanding of the nonlinear effects across relevant detector loading conditions, including how they impact on on-sky noise and how to diagnose the detector's relative performance. We present a study of the competing nonlinearities seen in Prime-Cam's 280 GHz aluminum KIDs, with a particular emphasis on the resulting distortions to the resonator line shape and how these impact detector parameter estimation.

astro-ph.IM↗