Searcharxiv⌕ Search

arXiv subjects

John A. B. Mates

Publications and source records attributed to John A. B. Mates.

15 recordsLinked to original sources

Design of a mission to measure the shape and substructure of the 511 keV gamma-ray line from the center of the Milky Way

The 511 keV electron-positron annihilation feature near the galactic center has been detected for more than half a century, yet its origin remains a mystery. In this paper, we describe a concept for a balloon-borne 511 keV $γ$-ray mission called the 511-Spectrometer Mission. The mission will use Transition-Edge Sensor (TES) arrays with thick metal absorbers that are thermally coupled to the TES. The strength of the approach is a projected energy resolution of 200 eV Full Width Half Maximum (FWHM) at 511 keV, enabling detailed studies of the shape and substructure of the 511 keV emission from the galactic center region. A first mission equipped with 8,192 $γ$-ray detectors and a fully active shield and collimator could detect the galactic center with ~35 $σ$ statistical significance. We present the mission concept as well as first results obtained with a prototype detector equipped with $1.35\times1.35\times2$ mm$^{3}$ Bi absorbers. The detector has a quantum efficiency of 15% for 511 keV photons in photoelectric effect interactions. In tests with a $^{137}$Cs source, these prototype detectors show an energy resolution of 525 eV FWHM at 662 keV. We end with a discussion of follow-up missions that use coded mask imaging, or use concentrating or focusing optics to scrutinize the sources of 511 keV $γ$-rays on smaller angular scales.

astro-ph.IM↗

Characterization of Silicon-Membrane TES Microcalorimeters for Large-Format X-ray Spectrometers with Integrated Microwave SQUID Readout

We present the electro-thermal characterization of transition-edge sensor (TES) detectors suspended on Si membranes fabricated using a silicon-on-insulator (SOI) wafer. The use of an all-silicon fabrication platform, in contrast to the more commonly used silicon nitride membranes, is compatible with monolithic fabrication of integrated TES and SQUID circuits. The all-silicon architecture additionally allows efficient use of focal plane area; the readout circuitry may be positioned out of the focal plane by bending a thinned portion of the chip. Compatibility with integrated fabrication and efficient use of focal plane area provide a path to an efficient soft X-ray spectrometer. This work is motivated by our goal to develop a 10,000-pixel TES spectrometer to overcome critical measurement limitations in catalysis research. The characterization of fragile, carbon-based intermediates via techniques like Resonant Inelastic X-ray Scattering (RIXS) is often precluded by the slow, high-flux nature of existing technologies. The new instrument will allow for fast RIXS measurements to be made without causing sample damage. We verify the detector models and measure the energy resolution using a pulsed optical laser, demonstrating the viability of this approach for the final instrument to be deployed at the National Synchrotron Light Source II (NSLS-II).

physics.ins-det↗

Lithographic integration of TES microcalorimeters with SQUID multiplexer circuits for large format spectrometers

Arrays of hundreds or thousands of low temperature detectors have been deployed for many experiments, both bolometers for long wavelength applications and calorimeters for shorter wavelength applications. One challenge that is common to many of these arrays is the efficient use of focal plane area to achieve a large fill fraction of absorbers coupled to detectors. We are developing an integrated fabrication of soft X-ray transition edge sensors (TES) and microwave SQUID multiplexers ($μ$MUX) with the goal of maximizing the fill fraction of the focal plane area on a scale of many thousand pixel detectors. We will utilize lithographically defined high density interconnects to circumvent limitations in existing solutions that use wirebonds or flip-chip bonds. Here we report the first demonstration of combining TES and $μ$MUX processes into a single TES-System-on-a-Chip (TES-SoC) fabrication on a silicon wafer. The $μ$MUX SQUIDs and TES electrothermal feedback circuits are microfabricated first and protected with passivating SiO$_2$, then the TES devices and TES-to-SQUID interconnects are fabricated, and finally the protective layer is removed before the fabrication of the microwave resonators. We show that the microwave SQUIDs are functional and have reasonable yield, and that we are able to read out the transition temperature of the connected TESs using those SQUIDs.

physics.ins-det↗

Kinetic inductance current sensor for visible to near-infrared wavelength transition-edge sensor readout

Single-photon detectors based on the superconducting transition-edge sensor are used in a number of visible to near-infrared applications, particularly for photon-number-resolving measurements in quantum information science. To be practical for large-scale spectroscopic imaging or photonic quantum computing applications, the size of visible to near-infrared transition-edge sensor arrays and their associated readouts must be increased from a few pixels to many thousands. In this manuscript, we introduce the kinetic inductance current sensor, a scalable readout technology that exploits the nonlinear kinetic inductance in a superconducting resonator to make sensitive current measurements. Kinetic inductance current sensors can replace superconducting quantum interference devices for many applications because of their ability to measure fast, high slew-rate signals, their compatibility with standard microwave frequency-division multiplexing techniques, and their relatively simple fabrication. Here, we demonstrate the readout of a visible to near-infrared transition-edge sensor using a kinetic inductance current sensor with 3.7 MHz of bandwidth. We measure a readout noise of 1.4 pA/$\sqrt{\text{Hz}}$, considerably below the detector noise at frequencies of interest, and an energy resolution of $(0.137 \pm 0.001)$ eV at 0.8 eV, comparable to resolutions observed with non-multiplexed superconducting quantum interference device readouts.

physics.ins-det↗

Crosstalk effects in microwave SQUID multiplexed TES bolometer readout

Transition-edge sensor (TES) bolometers are broadly used for background-limited astrophysical measurements from the far-infrared to mm-waves. Many planned future instruments require increasingly large detector arrays, but their scalability is limited by their cryogenic readout electronics. Microwave SQUID multiplexing offers a highly capable scaling solution through the use of inherently broadband circuitry, enabling readout of hundreds to thousands of channels per microwave line. As with any multiplexing technique, the channelization mechanism gives rise to electrical crosstalk which must be understood and controlled so as to not degrade the instrument sensitivity. Here, we explore implications relevant for TES bolometer array applications, focusing in particular on upcoming mm-wave observatories such as the Simons Observatory and AliCPT. We model the relative contributions of the various underlying crosstalk mechanisms, evaluate the difference between fixed-tone and tone-tracking readout systems, and discuss ways in which crosstalk nonlinearity will complicate on-sky measurements.

astro-ph.IM↗

ASCENT - A balloon-borne hard X-ray imaging spectroscopy telescope using transition edge sensor microcalorimeter detectors

Core collapse supernovae are thought to be one of the main sources in the galaxy of elements heavier than iron. Understanding the origin of the elements is thus tightly linked to our understanding of the explosion mechanism of supernovae and supernova nucleosynthesis. X-ray and gamma-ray observations of young supernova remnants, combined with improved theoretical modeling, have resulted in enormous improvements in our knowledge of these events. The isotope ${}^{44}$Ti is one of the most sensitive probes of the innermost regions of the core collapse engine, and its spatial and velocity distribution are key observables. Hard X-ray imaging spectroscopy with the Nuclear Spectroscopic Telescope Array (NuSTAR) has provided new insights into the structure of the supernova remnant Cassiopeia A (Cas A), establishing the convective nature of the supernova engine. However, many questions about the details of this engine remain. We present here the concept for a balloon-borne follow-up mission called ASCENT (A SuperConducting ENergetic x-ray Telescope). ASCENT uses transition edge sensor gamma-ray microcalorimeter detectors with a demonstrated 55 eV Full Width Half Maximum (FWHM) energy resolution at 97 keV. This 8--16-fold improvement in energy resolution over NuSTAR will allow high resolution imaging and spectroscopy of the ${}^{44}$Ti emission. This will allow a detailed reconstruction of gamma-ray line redshifts, widths, and shapes, allowing us to address questions such as: What is the source of the neutron star "kicks"? What is the dominant production pathway for ${}^{44}$Ti? Is the engine of Cas A unique?

astro-ph.IM↗

A tabletop x-ray tomography instrument for nanometer-scale imaging: demonstration of the 1,000-element transition-edge sensor subarray

We report on the 1,000-element transition-edge sensor (TES) x-ray spectrometer implementation of the TOMographic Circuit Analysis Tool (TOMCAT). TOMCAT combines a high spatial resolution scanning electron microscope (SEM) with a highly efficient and pixelated TES spectrometer to reconstruct three-dimensional maps of nanoscale integrated circuits (ICs). A 240-pixel prototype spectrometer was recently used to reconstruct ICs at the 130 nm technology node, but to increase imaging speed to more practical levels, the detector efficiency needs to be improved. For this reason, we are building a spectrometer that will eventually contain 3,000 TES microcalorimeters read out with microwave superconducting quantum interference device (SQUID) multiplexing, and we currently have commissioned a 1,000 TES subarray. This still represents a significant improvement from the 240-pixel system and allows us to begin characterizing the full spectrometer performance. Of the 992 maximimum available readout channels, we have yielded 818 devices, representing the largest number of TES x-ray microcalorimeters simultaneously read out to date. These microcalorimeters have been optimized for pulse speed rather than purely energy resolution, and we measure a FWHM energy resolution of 14 eV at the 8.0 keV Cu K$α$ line.

physics.ins-det↗

Design of a 3000-pixel transition-edge sensor x-ray spectrometer for microcircuit tomography

Feature sizes in integrated circuits have decreased substantially over time, and it has become increasingly difficult to three-dimensionally image these complex circuits after fabrication. This can be important for process development, defect analysis, and detection of unexpected structures in externally sourced chips, among other applications. Here, we report on a non-destructive, tabletop approach that addresses this imaging problem through x-ray tomography, which we uniquely realize with an instrument that combines a scanning electron microscope (SEM) with a transition-edge sensor (TES) x-ray spectrometer. Our approach uses the highly focused SEM electron beam to generate a small x-ray generation region in a carefully designed target layer that is placed over the sample being tested. With the high collection efficiency and resolving power of a TES spectrometer, we can isolate x-rays generated in the target from background and trace their paths through regions of interest in the sample layers, providing information about the various materials along the x-ray paths through their attenuation functions. We have recently demonstrated our approach using a 240 Mo/Cu bilayer TES prototype instrument on a simplified test sample containing features with sizes of $\sim$1 $μ$m. Currently, we are designing and building a 3000 Mo/Au bilayer TES spectrometer upgrade, which is expected to improve the imaging speed by factor of up to 60 through a combination of increased detector number and detector speed.

physics.ins-det↗

SLAC Microresonator RF (SMuRF) Electronics: A tone-tracking readout system for superconducting microwave resonator arrays

We describe the newest generation of the SLAC Microresonator RF (SMuRF) electronics, a warm digital control and readout system for microwave-frequency resonator-based cryogenic detector and multiplexer systems such as microwave SQUID multiplexers ($μ$mux) or microwave kinetic inductance detectors (MKIDs). Ultra-sensitive measurements in particle physics and astronomy increasingly rely on large arrays of cryogenic sensors, which in turn necessitate highly multiplexed readout and accompanying room-temperature electronics. Microwave-frequency resonators are a popular tool for cryogenic multiplexing, with the potential to multiplex thousands of detector channels on one readout line. The SMuRF system provides the capability for reading out up to 3328 channels across a 4-8 GHz bandwidth. Notably, the SMuRF system is unique in its implementation of a closed-loop tone-tracking algorithm that minimizes RF power transmitted to the cold amplifier, substantially relaxing system linearity requirements and effective noise from intermodulation products. Here we present a description of the hardware, firmware, and software systems of the SMuRF electronics, comparing achieved performance with science-driven design requirements. We focus in particular on the case of large channel count, low bandwidth applications, but the system has been easily reconfigured for high bandwidth applications. The system described here has been successfully deployed in lab settings and field sites around the world and is baselined for use on upcoming large-scale observatories.

physics.ins-det↗

Quantification of 242Pu with a Microcalorimeter Gamma Spectrometer

We report measurements of the 103-keV and 159-keV gamma ray signatures of 242Pu using microcalorimetry. This is the first observation of these gamma rays in a non-destructive measurement of an unprepared sample, and so represents an important advance in nuclear material accountancy. The measurement campaign also serves as the first demonstration of a field campaign with a portable microcalorimeter gamma-ray spectrometer. For the 103-keV gamma ray we report an improved centroid energy and emission probability.

physics.ins-det↗

The design of the Ali CMB Polarization Telescope receiver

Ali CMB Polarization Telescope (AliCPT-1) is the first CMB degree-scale polarimeter to be deployed on the Tibetan plateau at 5,250m above sea level. AliCPT-1 is a 90/150 GHz 72 cm aperture, two-lens refracting telescope cooled down to 4 K. Alumina lenses, 800mm in diameter, image the CMB in a 33.4° field of view on a 636mm wide focal plane. The modularized focal plane consists of dichroic polarization-sensitive Transition-Edge Sensors (TESes). Each module includes 1,704 optically active TESes fabricated on a 150mm diameter silicon wafer. Each TES array is read out with a microwave multiplexing readout system capable of a multiplexing factor up to 2,048. Such a large multiplexing factor has allowed the practical deployment of tens of thousands of detectors, enabling the design of a receiver that can operate up to 19 TES arrays for a total of 32,376 TESes. AliCPT-1 leverages the technological advancements in the detector design from multiple generations of previously successful feedhorn-coupled polarimeters, and in the instrument design from BICEP-3, but applied on a larger scale. The cryostat receiver is currently under integration and testing. During the first deployment year, the focal plane will be populated with up to 4 TES arrays. Further TES arrays will be deployed in the following years, fully populating the focal plane with 19 arrays on the fourth deployment year. Here we present the AliCPT-1 receiver design, and how the design has been optimized to meet the experimental requirements.

astro-ph.IM↗

Microwave multiplexing on the Keck Array

We describe an on-sky demonstration of a microwave-multiplexing readout system in one of the receivers of the Keck Array, a polarimetry experiment observing the cosmic microwave background at the South Pole. During the austral summer of 2018-2019, we replaced the time-division multiplexing readout system with microwave-multiplexing components including superconducting microwave resonators coupled to radio-frequency superconducting quantum interference devices at the sub-Kelvin focal plane, coaxial-cable plumbing and amplification between room temperature and the cold stages, and a SLAC Microresonator Radio Frequency system for the warm electronics. In the range 5-6 GHz, a single coaxial cable reads out 528 channels. The readout system is coupled to transition-edge sensors, which are in turn coupled to 150-GHz slot-dipole phased-array antennas. Observations began in April 2019, and we report here on an initial characterization of the system performance.

astro-ph.IM↗

A Model for Excess Johnson Noise in Superconducting Transition-edge Sensors

Transition-Edge Sensors (TESs) are two-dimensional superconducting films used to detect energy or power. TESs are voltage biased in the resistive transition where the film resistance is both finite and a strong function of temperature. Electrical noise is observed in TESs that exceeds the predictions of existing noise theories. In this manuscript, we describe a model for the unexplained excess noise based on the dynamic resistance of the TES and noise mixed down from frequencies around the Josephson oscillations. We derive an expression for the power spectral density of this noise and show that its predictions match measured data.

cond-mat.supr-con↗

Highly-multiplexed microwave SQUID readout using the SLAC Microresonator Radio Frequency (SMuRF) Electronics for Future CMB and Sub-millimeter Surveys

The next generation of cryogenic CMB and submillimeter cameras under development require densely instrumented sensor arrays to meet their science goals. The readout of large numbers ($\sim$10,000--100,000 per camera) of sub-Kelvin sensors, for instance as proposed for the CMB-S4 experiment, will require substantial improvements in cold and warm readout techniques. To reduce the readout cost per sensor and integration complexity, efforts are presently focused on achieving higher multiplexing density while maintaining readout noise subdominant to intrinsic detector noise. Highly-multiplexed cold readout technologies in active development include Microwave Kinetic Inductance Sensors (MKIDs) and microwave rf-SQUIDs. Both exploit the high quality factors of superconducting microwave resonators to densely channelize sub-Kelvin sensors into the bandwidth of a microwave transmission line. We present advancements in the development of a new warm readout system for microwave SQUID multiplexing, the SLAC Superconducting Microresonator RF electronics, or SMuRF. The SMuRF system is unique in its ability to track each tone, minimizing the total RF power required to read out each resonator, thereby significantly reducing the linearity requirements on the cold and warm readout. Here, we present measurements of the readout noise and linearity of the first full SMuRF system, including a demonstration of closed-loop tone tracking on a 528 channel cryogenic microwave SQUID multiplexer. SMuRF is being explored as a potential readout solution for several future CMB projects including Simons Observatory, BICEP Array, CCAT-prime, Ali-CPT, and CMB-S4. Parallel development of the platform is underway to adapt SMuRF to read out both MKID and fast X-ray TES calorimeter arrays.

astro-ph.IM↗

High-resolution gamma-ray spectroscopy with a microwave-multiplexed transition-edge sensor array

We demonstrate very high resolution photon spectroscopy with a microwave-multiplexed two-pixel transition-edge sensor (TES) array. We measured a $^{153}$Gd photon source and achieved an energy resolution of 63 eV full-width-at-half-maximum at 97 keV and an equivalent readout system noise of 86 pA/$\sqrt{\text{Hz}}$ at the TES. The readout circuit consists of superconducting microwave resonators coupled to radio-frequency superconducting-quantum-interference-devices (SQUID) and transduces changes in input current to changes in phase of a microwave signal. We use flux-ramp modulation to linearize the response and evade low-frequency noise. This demonstration establishes one path for the readout of cryogenic X-ray and gamma-ray sensor arrays with more than $10^3$ elements and spectral resolving powers $R=λ/Δλ> 10^3$.

physics.ins-det↗