SearcharxivSearch

arXiv subjects

John A. Ely

Publications and source records attributed to John A. Ely.

3 recordsLinked to original sources

Optimisation of calibration sources for global 21-cm experiments: the REACH case

The spin-flip 21-cm signal from the Cosmic Dawn and the Epoch of Reionization is an essential probe of the conditions that led to the formation of the first luminous objects in the early Universe. However, its detection remains a major challenge owing to its low strength compared to the bright foregrounds and the requirement of precise calibration of the instrument to prevent systematics that could hinder a detection or lead to false inferences. REACH (Radio Experiment for the Analysis of Cosmic Hydrogen) is a radiometer experiment designed to detect this sky-averaged signal in the frequency range of 50--130~MHz. Using a wide-beam antenna, REACH calibration relies on internal reference sources, covering a broad range of temperatures and reflection coefficients. The choice of type and number of calibrators used significantly influences the quality of the calibration. This work investigates these effects and introduces a novel method for selecting an optimal set of calibration sources. With an optimised set, we aim to reduce calibration time, thereby increasing sky integration time while preserving calibration accuracy. We explore two optimisation strategies: one applied across the full receiver band and another performed on a frequency-by-frequency basis. Finally, we demonstrate that, with a total calibration time comparable to the conventional full-calibrator set, an optimised set with fewer calibrators achieves approximately a $15~\%$ reduction in calibrated temperature noise and improved absolute calibration of the instrument. This has implications for better calibration strategies in similar radiometer experiments.

astro-ph.IM

Receiver design for the REACH global 21-cm signal experiment

We detail the the REACH radiometric system designed to enable measurements of the 21-cm neutral hydrogen line. Included is the radiometer architecture and end-to-end system simulations as well as a discussion of the challenges intrinsic to highly-calibratable system development. Following this, we share laboratory results based on the calculation of noise wave parameters utilising an over-constrained least squares approach demonstrating a calibration RMSE of 80 mK for five hours of integration on a custom-made source with comparable impedance to that of the antenna used in the field. This paper therefore documents the state of the calibrator and data analysis in December 2022 in Cambridge before shipping to South Africa.

astro-ph.IM

A Digital Correlator Upgrade for the Arcminute MicroKelvin Imager

The Arcminute Microkelvin Imager (AMI) telescopes located at the Mullard Radio Astronomy Observatory near Cambridge have been significantly enhanced by the implementation of a new digital correlator with 1.2 MHz spectral resolution. This system has replaced a 750-MHz resolution analogue lag-based correlator, and was designed to mitigate the effects of radio frequency interference, particularly from geostationary satellites that contaminate observations at low declinations. The upgraded instrument consists of 18 ROACH2 Field Programmable Gate Array platforms used to implement a pair of real-time FX correlators -- one for each of AMI's two arrays. The new system separates the down-converted RF baseband signal from each AMI receiver into two 2.3 GHz-wide sub-bands which are each digitized at 5-Gsps with 8 bits of precision. These digital data streams are filtered into 2048 frequency channels and cross-correlated using FPGA hardware, with a commercial 10 Gb Ethernet switch providing high-speed data interconnect. Images formed using data from the new digital correlator show over an order of magnitude improvement in dynamic range over the previous system. The ability to observe at low declinations has also been significantly improved.

astro-ph.IM