SearcharxivSearch

arXiv subjects

John Annand

Publications and source records attributed to John Annand.

9 recordsLinked to original sources

A Helical-Deflector-Based Radio-Frequency Spiral Scanning System for keV Energy Electrons

We present the design, modeling, and experimental validation of a radio-frequency based time-to-position conversion system for keV electrons incorporating a helical deflector operating in the 400-1000 MHz range. The device performs circular deflection of the electrons when driven by a single RF frequency and enables spiral scanning when two phase-locked RF voltages with slightly different frequencies are applied. The superposition of the two phase-locked RF voltages produces an amplitude-beating field whose slowly varying envelope modulates the deflection radius, transforming the circular scan into a controlled spiral on the detector plane. A detailed theoretical model describing the electron dynamics under two phase-locked RF voltages with different frequencies was derived, yielding analytical expressions for the transverse velocity and radius-vector components at the deflector exit. The experimental studies demonstrated good agreement with the model predictions. Spiral scanning will allow measurements with picosecond resolution in a temporal dynamic range 1-2 orders of magnitude larger than the period of the circular scanning.

physics.ins-det

Compact sub-10 ps Resolution Radio Frequency Photomultiplier Tube

Experimental measurements of the radial spreading of photoelectrons emitted from a multi-alkali photocathode in a MCP-based photomultiplier tube have shown that, for photon wavelengths of 455 nm, 515 nm and 625 nm, the maximum initial energies of the emitted photoelectrons are approximately 0.3 eV, 0.2 eV and 0.1 eV respectively. Combining these experimental results with simulations performed using the SIMION simulation package, a compact radio-frequency photoelectron multiplier tube with a temporal resolution better than 10 ps is proposed. The device would be suitable for applications in several fields, particularly in medical optical instruments employing time-correlated single-photon counting.

physics.ins-det

Picosecond Precision Heavy-Ion Detector for Λ Hypernuclei Lifetime Studies

In this paper, we present the design and preliminary performance evaluation of a new heavy-ion detector for direct measurements of heavy Λ hypernuclei lifetime. The detector employs the previously developed 10 picosecond resolution Radio Frequency (RF) Timer, which converts the temporal information of incident particles into spatial coordinates of secondary or photoelectrons on a position-sensitive detector by means of circular RF scanning in the 500-1000 MHz range. Here, we report the detector design to achieve efficient suppression of accidental background and effective separation of prompt reaction products and delayed events from Λ hypernuclei decays, results of test studies carried out with RF synchronized laser as well as preliminary results obtained by using alpha particles. Dedicated Monte-Carlo simulations have been performed to estimate the detector's performance under realistic experimental conditions at RF-driven electron, photon, or proton beams. The results confirm the feasibility of the proposed design and provide a basis for upcoming experimental measurements, based on the delayed fission detection.

physics.ins-det

Advanced Radio Frequency Timing AppaRATus (ARARAT) Technique and Applications

The development of the advanced Radio Frequency Timer of electrons is described. It is based on a helical deflector, which performs circular or elliptical sweeps of keV electrons, by means of 500 MHz radio frequency field. By converting a time distribution of incident electrons to a hit position distribution on a circle or ellipse, this device achieves extremely precise timing. Streak Cameras, based on similar principles, routinely operate in the ps and sub-ps time domain, but have substantial slow readout system. Here, we report a device, where the position sensor, consisting of microchannel plates and a delay-line anode, produces ~ns duration pulses which can be processed by using regular fast electronics. A photon sensor based on this technique, the Radio Frequency Photo-Multiplier Tube (RFPMT), has demonstrated a timing resolution of ~10 ps and a time stability of ~0.5 ps, FWHM. This makes the apparatus highly suited for Time Correlated Single Photon Counting which is widely used in optical microscopy and tomography of biological samples. The first application in lifetime measurements of quantum states of graphene, under construction at the A. I. Alikhanyan National Science Laboratory (AANL), is outlined. This is followed by a description of potential RFPMT applications in time-correlated Diffuse Optical Tomography, time-correlated Stimulated Emission Depletion microscopy, hybrid FRET/STED nanoscopy and Time-of-Flight Positron Emission Tomography.

physics.ins-det

An RF Timer of Electrons and Photons with the Potential to reach Picosecond Precision

This paper describes a new radio frequency timer of keV energy electrons. It is based on a helical deflector, which performs circular or elliptical sweeps of keV electrons, by means of 500 MHz radio frequency field. By converting a time distribution of incident electrons to a hit position distribution on a circle or ellipse, this device achieves extremely precise timing. Streak Cameras, based on similar principles, routinely operate in the ps and sub-ps time domain, but have substantial dead time associated with the readout system. Here, we report a new type of RF timing technique, where the position sensor, consisting of microchannel plates and a delay-line anode, produces ~ns duration pulses with small dead time. Measurements made with sub-ps duration laser pulses, synchronized to the radio frequency power, produced a timing resolution of ~10 ps. This ultra-high precision technique has potential applications in a large variety of scientific devices, and in all cases, electrons are timed and detected simultaneously in the same device.

physics.ins-det

A comparison of untagged gamma-ray and tagged-neutron yields from 241AmBe and 238PuBe sources

Untagged gamma-ray and tagged-neutron yields from 241AmBe and 238PuBe mixed-field sources have been measured. Gamma-ray spectroscopy measurements from 1 - 5 MeV were performed in an open environment using a CeBr3 detector and the same experimental conditions for both sources. The shapes of the distributions are very similar and agree well with previous data. Tagged-neutron measurements from 2 - 6 MeV were performed in a shielded environment using a NE-213 liquid-scintillator detector for the neutrons and a YAP(Ce) detector to tag the 4.44 MeV gamma-rays associated with the de-excitation of the first excited state of 12C. Again, the same experimental conditions were used for both sources. The shapes of these distributions are also very similar and agree well with previous data, each other, and the ISO recommendation. Our 238PuBe source provides approximately 2.6 times more 4.44 MeV gamma-rays and 2.4 times more neutrons over the tagged-neutron energy range, the latter in reasonable agreement with the original full-spectrum source-calibration measurements performed at the time of their acquisition.

physics.ins-det

Tagging fast neutrons from a 252Cf fission-fragment source

Coincidence and time-of-flight measurement techniques are employed to tag fission neutrons emitted from a 252Cf source sealed on one side with a very thin layer of Au. The source is positioned within a gaseous 4He scintillator detector. Together with alpha particles, both light and heavy fission fragments pass through the thin layer of Au and are detected. The fragments enable the corresponding fission neutrons, which are detected in a NE-213 liquid-scintillator detector, to be tagged. The resulting continuous polychromatic beam of tagged neutrons has an energy dependence that agrees qualitatively with expectations. We anticipate that this technique will provide a cost-effective means for the characterization of neutron-detector efficiency in the energy range 1 - 6 MeV.

nucl-ex

Compton Scattering from the Deuteron below Pion-Production Threshold

Differential cross sections for elastic scattering of photons from the deuteron have recently been measured at the Tagged-Photon Facility at the MAX IV Laboratory in Lund, Sweden. These first new measurements in more than a decade further constrain the isoscalar electromagnetic polarizabilities of the nucleon and provide the first-ever results above 100 MeV, where the sensitivity to the polarizabilities is increased. We add 23 points between 70 and 112 MeV, at angles 60deg, 120deg and 150deg. Analysis of these data using a Chiral Effective Field Theory indicates that the cross sections are both self-consistent and consistent with previous measurements. Extracted values of α_s = [12.1 +/- 0.8(stat) +/- 0.2(BSR) +/- 0.8(th)] X 10^{-4} fm^3 and β_s = [2.4 +/- 0.8(stat) +/- 0.2(BSR) +/- 0.8(th)] X 10^{-4} fm^3 are obtained from a fit to these 23 new data points. This paper presents in detail the experimental conditions and the data analysis used to extract the cross sections.

nucl-ex

A Radio Frequency Helical Deflector for keV Electrons

This paper describes a helical deflector to perform circular sweeps of keV electrons by means of radio frequency fields in a frequency range 500-1000 MHz. By converting the time dependence of incident electrons to a hit position dependence on a circle, this device can potentially achieve extremely precise timing. The system can be adjusted to the velocity of the electrons to exclude the reduction of deflection sensitivity due to finite transit time effects. The deflection electrodes form a resonant circuit, with quality factor Q in excess of 100, and at resonance the sensitivity of the deflection system is around 1~mm per V of applied RF input.

physics.acc-ph