Initial Performance of a Long Axial FOV PET with TOF and DOI capabilities: IMAS system

This work summarizes the design, construction, initial performance evaluation and pilot clinical results of the IMAS system, a long axial field of view (FOV), also known as total-body (TB-), positron emission tomography (PET) prototype scanner. This PET enables for the first time in TB-PET imaging, simultaneously time-of-flight (TOF) and depth-of-interaction (DOI) capabilities. The IMAS detector block is based on LYSO semi monolithic scintillators, with individual slab sizes of 3 mm x 25 mm x 20 mm each. Arrays of 1x8 slabs are coupled to 8x8 Silicon Photomultiplier arrays. A proprietary readout reduces the 64 signals to only 16 outputs, preserving both 3D photon impact positioning and timing accuracy. IMAS has a total of 30,720 channels. PETsys electronics is used for data acquisition. The IMAS geometry is based on 5 rings of 10 cm each, with a 5 cm gap between them. It defines an axial FOV of 71 cm with a bore aperture of 82 cm. We report in this work the pilot tests of the system performance and the first clinical results. We found that the system spatial resolution remained below 4 mm across the entire FOV, even at the off-radial position of 30 cm. A coincidence time resolution with a small size 22Na source of 560 ps FWHM was measured. A sensitivity of 56.54 cps/kBq is in good agreement with previous simulation studies; however, the noise equivalent count rates performance (79 kcps at 3.26 kBq/mL) was significantly lower than expected, likely due to a data transfer bottleneck between the system and the acquisition workstation. Finally, a comparison of one of the imaged patients with a commercial TOF PET/CT scanner is also provided, pinpointing an improved tumor identification for IMAS, and the advantages of TOF and especially DOI capabilities.

physics.med-ph

Reduction Signals Method Preserving Spatial and Temporal Capabilities

In gamma ray imaging, a scintillation crystal is typically used to convert the gamma radiation into visible light. Photosensors are used to transform this light into measurable signals. Several types of photosensors are currently in use depending on the application, most known are Position Sensitive Photomultiplier Tubes (PSPMT) or arrays of Silicon Photomultipliers (SiPMs). There have been investigations towards reducing the number of output signals from those photosensors in order to decrease system costs and complexity without impacting system performance. We propose here two different reduction schemes without degradation of the detector performance, keeping a good spatial, energy and timing resolution, specially well suited for monolithic scintillation crystals based detectors. We have carried out comparative results that will be shown.

physics.ins-det

Characterization of TOF-PET Detectors Based on Monolithic Blocks and ASIC-Readout

The aim of this work is to show the potential capabilities of monolithic crystals coupled to large SiPM arrays, to be considered as detector blocks for PET scanners enabling Time Of Flight (TOF) capabilities. Monolithic blocks allow one to decode the 3D photon impact position. This approach, along with TOF information, can be of high interest in clinical Positron emission tomography (PET) applications where a typical ring configuration is used. In this manuscript, we evaluate an ASIC- based readout for digitizing all signals coming from analog photosensors. Validation results with one-to-one coupling resulted in a Coincidence Time Resolution (CTR) of 202 ps FWHM. Providing timing resolution when using detectors based on monolithic crystals is however challenging. The wide distribution of scintillation light on the photosensors causes a poor SNR, which makes the system sensible to false triggering and to time walk errors. In this direction, we present a calibration method, designed to correct all recorded timestamps and also to compensate variations in time-paths among all channels. Thereafter, a CTR improvement nearing 45% is observed for all measurements. Moreover, we show a novel approach that describes the use of averaging methods to assign a single timestamp to each gamma impact. This approach results in a further improvement of the CTR in the range of 100 ps FWHM, reaching a time resolution of 585 ps FWHM when using a large 50x50x10 mm3 LYSO scintillator coupled to an 8x8 SiPM (6x6 mm2) array. These pilot studies show detector capabilities regarding TOF information when using monolithic scintillators.

physics.ins-det