Searcharxiv⌕ Search

arXiv subjects

John Chiaverini

Publications and source records attributed to John Chiaverini.

27 records · Page 2Linked to original sources

Trapped-Ion Quantum Computing: Progress and Challenges

Trapped ions are among the most promising systems for practical quantum computing (QC). The basic requirements for universal QC have all been demonstrated with ions and quantum algorithms using few-ion-qubit systems have been implemented. We review the state of the field, covering the basics of how trapped ions are used for QC and their strengths and limitations as qubits. In addition, we discuss what is being done, and what may be required, to increase the scale of trapped ion quantum computers while mitigating decoherence and control errors. Finally, we explore the outlook for trapped-ion QC. In particular, we discuss near-term applications, considerations impacting the design of future systems of trapped ions, and experiments and demonstrations that may further inform these considerations.

quant-ph↗

Low-loss integrated photonics for the blue and ultraviolet regime

We present a low-loss integrated photonics platform in the visible and near ultraviolet regime. Fully-etched waveguides based on atomic layer deposition (ALD) of aluminum oxide operate in a single transverse mode with $<$3 dB/cm propagation loss at a wavelength of 371 nm. Ring resonators with intrinsic quality factors exceeding 470,000 are demonstrated at 405 nm, and the thermo optic coefficient of ALD aluminum oxide is estimated to be $2.75\times10^{-5}$ [RIU/$^\circ$C]. Absorption loss is sufficiently low to allow on-resonance operation with intra-cavity powers up to at least 12.5 mW, limited by available laser power. Experimental and simulated data indicates the propagation loss is dominated by sidewall roughness, suggesting lower loss in the blue and UV is achievable.

physics.optics↗

Heisenberg scaling of imaging resolution by coherent enhancement

Classical imaging works by scattering photons from an object to be imaged, and achieves resolution scaling as $1/\sqrt{t}$, with $t$ the imaging time. By contrast, the laws of quantum mechanics allow one to utilize quantum coherence to obtain imaging resolution that can scale as quickly as $1/t$ -- the so-called "Heisenberg limit." However, ambiguities in the obtained signal often preclude taking full advantage of this quantum enhancement, while imaging techniques designed to be unambiguous often lose this optimal Heisenberg scaling. Here, we demonstrate an imaging technique which combines unambiguous detection of the target with Heisenberg scaling of the resolution. We also demonstrate a binary search algorithm which can efficiently locate a coherent target using the technique, resolving a target trapped ion to within 0.3% of the $1/e^2$ diameter of the excitation beam.

physics.atom-ph↗

High-Fidelity, Single-Shot, Quantum-Logic-Assisted Readout in a Mixed-Species Ion Chain

We use a co-trapped ion ($^{88}\mathrm{Sr}^{+}$) to sympathetically cool and measure the quantum state populations of a memory-qubit ion of a different atomic species ($^{40}\mathrm{Ca}^{+}$) in a cryogenic, surface-electrode ion trap. Due in part to the low motional heating rate demonstrated here, the state populations of the memory ion can be transferred to the auxiliary ion by using the shared motion as a quantum state bus and measured with an average accuracy of 96(1)%. This scheme can be used in quantum information processors to reduce photon-scattering-induced error in unmeasured memory qubits.

physics.atom-ph↗

Integrated optical addressing of an ion qubit

The long coherence times and strong Coulomb interactions afforded by trapped ion qubits have enabled realizations of the necessary primitives for quantum information processing (QIP), and indeed the highest-fidelity quantum operations in any qubit to date. But while light delivery to each individual ion in a system is essential for general quantum manipulations and readout, experiments so far have employed optical systems cumbersome to scale to even a few tens of qubits. Here we demonstrate lithographically defined nanophotonic waveguide devices for light routing and ion addressing fully integrated within a surface-electrode ion trap chip. Ion qubits are addressed at multiple locations via focusing grating couplers emitting through openings in the trap electrodes to ions trapped 50 $μ$m above the chip; using this light we perform quantum coherent operations on the optical qubit transition in individual $^{88}$Sr$^+$ ions. The grating focuses the beam to a diffraction-limited spot near the ion position with a 2 $μ$m 1/$e^2$-radius along the trap axis, and we measure crosstalk errors between $10^{-2}$ and $4\times10^{-4}$ at distances 7.5-15 $μ$m from the beam center. Owing to the scalability of the planar fabrication employed, together with the tight focusing and stable alignment afforded by optics integration within the trap chip, this approach presents a path to creating the optical systems required for large-scale trapped-ion QIP.

physics.atom-ph↗

Reduction of trapped ion anomalous heating by in situ surface plasma cleaning

Anomalous motional heating is a major obstacle to scalable quantum information processing with trapped ions. While the source of this heating is not yet understood, several previous studies suggest that surface contaminants may be largely responsible. We demonstrate an improvement by a factor of four in the room-temperature heating rate of a niobium surface electrode trap by in situ plasma cleaning of the trap surface. This surface treatment was performed with a simple homebuilt coil assembly and commercially-available matching network and is considerably gentler than other treatments, such as ion milling or laser cleaning, that have previously been shown to improve ion heating rates. We do not see an improvement in the heating rate when the trap is operated at cryogenic temperatures, pointing to a role of thermally-activated surface contaminants in motional heating whose activity may freeze out at low temperatures.

physics.atom-ph↗

Loading of a surface-electrode ion trap from a remote, precooled source

We demonstrate loading of ions into a surface-electrode trap (SET) from a remote, laser-cooled source of neutral atoms. We first cool and load $\sim$ $10^6$ neutral $^{88}$Sr atoms into a magneto-optical trap from an oven that has no line of sight with the SET. The cold atoms are then pushed with a resonant laser into the trap region where they are subsequently photoionized and trapped in an SET operated at a cryogenic temperature of 4.6 K. We present studies of the loading process and show that our technique achieves ion loading into a shallow (15 meV depth) trap at rates as high as 125 ions/s while drastically reducing the amount of metal deposition on the trap surface as compared with direct loading from a hot vapor. Furthermore, we note that due to multiple stages of isotopic filtering in our loading process, this technique has the potential for enhanced isotopic selectivity over other loading methods. Rapid loading from a clean, isotopically pure, and precooled source may enable scalable quantum information processing with trapped ions in large, low-depth surface trap arrays that are not amenable to loading from a hot atomic beam.

physics.atom-ph↗

Precision measurement of the 5 2S1/2 - 4 2D5/2 quadrupole transition isotope shift between 88Sr+ and 86Sr+

We have measured the isotope shift of the narrow quadrupole-allowed 5 2S1/2 - 4 2D5/2 transition in 86Sr+ relative to the most abundant isotope 88Sr+. This was accomplished using high-resolution laser spectroscopy of individual trapped ions, and the measured shift is Delta-nu_meas^(88,86) = 570.281(4) MHz. We have also tested a recently developed and successful method for ab-initio calculation of isotope shifts in alkali-like atomic systems against this measurement, and our initial result of Delta-nu_calc^(88,86) = 457(28) MHz is also presented. To our knowledge, this is the first high precision measurement and calculation of that isotope shift. While the measurement and the calculation are in broad agreement, there is a clear discrepancy between them, and we believe that the specific mass shift was underestimated in our calculation. Our measurement provides a stringent test for further refinements of theoretical isotope shift calculation methods for atomic systems with a single valence electron.

physics.atom-ph↗

Improved constraints on non-Newtonian forces at 10 microns

Several recent theories suggest that light moduli or particles in "large" extra dimensions could mediate macroscopic forces exceeding gravitational strength at length scales below a millimeter. Such new forces can be parameterized as a Yukawa-type correction to the Newtonian potential of strength $α$ relative to gravity and range $λ$. To extend the search for such new physics we have improved our apparatus utilizing cryogenic micro-cantilevers capable of measuring attonewton forces, which now includes a switchable magnetic force for calibration. Our most recent experimental constraints on Yukawa-type deviations from Newtonian gravity are more than three times as stringent as our previously published results, and represent the best bound in the range of 5 - 15 microns, with a 95 percent confidence exclusion of forces with $|α| > 14,000$ at $λ$ = 10 microns.

hep-ex↗