SearcharxivSearch

arXiv subjects

John F. Barry

Publications and source records attributed to John F. Barry.

12 recordsLinked to original sources

The impact of microwave phase noise on diamond quantum sensing

Precision optical measurements of the electron-spin precession of nitrogen-vacancy (NV) centers in diamond form the basis of numerous applications. The most sensitivity-demanding applications, such as femtotesla magnetometry, require the ability to measure changes in GHz spin transition frequencies at the sub-millihertz level, corresponding to a fractional resolution of better than 10^{-12}. Here we study the impact of microwave (MW) phase noise on the response of an NV sensor. Fluctuations of the phase of the MW waveform cause undesired rotations of the NV spin state. These fluctuations are imprinted in the optical readout signal and, left unmitigated, are indistinguishable from magnetic field noise. We show that the phase noise of several common commercial MW generators results in an effective pT s^{1/2}-range noise floor that varies with the MW carrier frequency and the detection frequency of the pulse sequence. The data are described by a frequency domain model incorporating the MW phase noise spectrum and the filter-function response of the sensing protocol. For controlled injection of white and random-walk phase noise, the observed NV magnetic noise floor is described by simple analytic expressions that accurately capture the scaling with pulse sequence length and the number of pi pulses. We outline several strategies to suppress the impact of MW phase noise and implement a version, based on gradiometry, that realizes a >10-fold suppression. Our study highlights an important challenge in the pursuit of sensitive diamond quantum sensors and is applicable to other qubit systems with a large transition frequency.

quant-ph

Ferrimagnetic Oscillator Magnetometer

Quantum sensors offer unparalleled precision, accuracy, and sensitivity for a variety of measurement applications. We report a compact magnetometer based on a ferrimagnetic sensing element in an oscillator architecture that circumvents challenges common to other quantum sensing approaches such as limited dynamic range, limited bandwidth, and dependence on vacuum, cryogenic, or laser components. The device exhibits a fixed, calibration-free response governed by the electron gyromagnetic ratio. Exchange narrowing in the ferrimagnetic material produces sub-MHz transition linewidths despite the high unpaired spin density ($\sim 10^{22}$ cm$^{-3}$). The magnetometer achieves a minimum sensitivity of 100 fT/$\sqrt{\text{Hz}}$ to AC magnetic fields of unknown phase and a sensitivity below 200 fT/$\sqrt{\text{Hz}}$ over a bandwidth $\gtrsim \! 1$ MHz. By encoding magnetic field in frequency rather than amplitude, the device provides a dynamic range in excess of 1 mT. The passive, thermal initialization of the sensor's quantum state requires only a magnetic bias field, greatly reducing power requirements compared to laser-initialized quantum sensors. With additional development, this device promises to be a leading candidate for high-performance magnetometry outside the laboratory, and the oscillator architecture is expected to provide advantages across a wide range of sensing platforms.

quant-ph

Sensitive AC and DC Magnetometry with Nitrogen-Vacancy Center Ensembles in Diamond

Quantum sensing with solid-state spins offers the promise of high spatial resolution, bandwidth, and dynamic range at sensitivities comparable to more mature quantum sensing technologies, such as atomic vapor cells and superconducting devices. However, despite comparable theoretical sensitivity limits, the performance of bulk solid-state quantum sensors has so far lagged behind these more mature alternatives. A recent review~\cite{barry2020sensitivity} suggests several paths to improve performance of magnetometers employing nitrogen-vacancy defects in diamond, the most-studied solid-state quantum sensing platform. Implementing several suggested techniques, we demonstrate the most sensitive nitrogen-vacancy-based bulk magnetometer reported to date. Our approach combines tailored diamond growth to achieve low strain and long intrinsic dephasing times, the use of double-quantum Ramsey and Hahn echo magnetometry sequences for broadband and narrowband magnetometry respectively, and P1 driving to further extend dephasing time. Notably, the device does not include a flux concentrator, preserving the fixed response of the NVs to magnetic field. The magnetometer realizes a broadband \textcolor{mhsnew}{near-}DC sensitivity $\sim 460$~fT$\cdot$s$^{1/2}$ and a narrowband AC sensitivity $\sim 210$~fT$\cdot$s$^{1/2}$. We describe the experimental setup in detail and highlight potential paths for future improvement.

quant-ph

A Solid-State Microwave Magnetometer with Picotesla-Level Sensitivity

Quantum sensing of low-frequency magnetic fields using nitrogen-vacancy (NV) center ensembles has been demonstrated in multiple experiments with sensitivities as low as $\sim$1 pT/$\sqrt{\text{Hz}}$. To date, however, demonstrations of high-frequency magnetometry in the GHz regime with NV diamond are orders of magnitude less sensitive, above the nT/$\sqrt{\text{Hz}}$ level. Here we adapt for microwave frequencies techniques that have enabled high-performance, low-frequency quantum sensors. Using a custom-grown NV-enriched diamond combined with a noise cancellation scheme designed for high-frequency sensing, we demonstrate a Rabi-sequence-based magnetometer able to detect microwave fields near 2.87 GHz with a record sensitivity of 3.4 pT/$\sqrt{\textrm{Hz}}$. We demonstrate both amplitude and phase sensing and project tunability over a 300 MHz frequency range. This result increases the viability of NV ensembles to serve as microwave circuitry imagers and near-field probes of antennas.

quant-ph

Sensitivity Optimization for NV-Diamond Magnetometry

Solid-state spin systems including nitrogen-vacancy (NV) centers in diamond constitute an increasingly favored quantum sensing platform. However, present NV ensemble devices exhibit sensitivities orders of magnitude away from theoretical limits. The sensitivity shortfall both handicaps existing implementations and curtails the envisioned application space. This review analyzes present and proposed approaches to enhance the sensitivity of broadband ensemble-NV-diamond magnetometers. Improvements to the spin dephasing time, the readout fidelity, and the host diamond material properties are identified as the most promising avenues and are investigated extensively. Our analysis of sensitivity optimization establishes a foundation to stimulate development of new techniques for enhancing solid-state sensor performance.

quant-ph

Cavity quantum electrodynamic readout of a solid-state spin sensor

Robust, high-fidelity readout is central to quantum device performance. Overcoming poor readout is an increasingly urgent challenge for devices based on solid-state spin defects, particularly given their rapid adoption in quantum sensing, quantum information, and tests of fundamental physics. Spin defects in solids combine the repeatability and precision available to atomic and cryogenic systems with substantial advantages in compactness and range of operating conditions. However, in spite of experimental progress in specific systems, solid-state spin sensors still lack a universal, high-fidelity readout technique. Here we demonstrate high-fidelity, room-temperature readout of an ensemble of nitrogen-vacancy (NV) centers via strong coupling to a dielectric microwave cavity, building on similar techniques commonly applied in cryogenic circuit cavity quantum electrodynamics. This strong collective interaction allows the spin ensemble's microwave transition to be probed directly, thereby overcoming the optical photon shot noise limitations of conventional fluorescence readout. Applying this technique to magnetometry, we show magnetic sensitivity approaching the Johnson-Nyquist noise limit of the system. This readout technique is viable for the many paramagnetic spin systems that exhibit resonances in the microwave domain. Our results pave a clear path to achieve unity readout fidelity of solid-state spin sensors through increased ensemble size, reduced spin-resonance linewidth, or improved cavity quality factor.

quant-ph

Decoherence of dipolar spin ensembles in diamond

We present a combined theoretical and experimental study of solid-state spin decoherence in an electronic spin bath, focusing specifically on ensembles of nitrogen vacancy (NV) color centers in diamond and the associated substitutional nitrogen spin bath. We perform measurements of NV spin free induction decay times $T_2^*$ and spin-echo coherence times $T_2$ in 25 diamond samples with nitrogen concentrations [N] ranging from 0.01 to 300\,ppm. We introduce a microscopic model and perform numerical simulations to quantitatively explain the degradation of both $T_2^*$ and $T_2$ over four orders of magnitude in [N]. Our results resolve a long-standing discrepancy observed in NV $T_2$ experiments, enabling us to describe NV ensemble spin coherence decay shapes as emerging consistently from the contribution of many individual NV.

quant-ph

Hamiltonian Engineering with Constrained Optimization for Quantum Sensing and Control

While quantum devices rely on interactions between constituent subsystems and with their environment to operate, native interactions alone often fail to deliver targeted performance. Coherent pulsed control provides the ability to tailor effective interactions, known as Hamiltonian engineering. We propose a Hamiltonian engineering method that maximizes desired interactions while mitigating deleterious ones by conducting a pulse sequence search using constrained optimization. The optimization formulation incorporates pulse sequence length and cardinality penalties consistent with linear or integer programming. We apply the general technique to magnetometry with solid state spin ensembles in which inhomogeneous interactions between sensing spins limit coherence. Defining figures of merit for broadband Ramsey magnetometry, we present novel pulse sequences which outperform known techniques for homonuclear spin decoupling in both spin-1/2 and spin-1 systems. When applied to nitrogen vacancy (NV) centers in diamond, this scheme partially preserves the Zeeman interaction while zeroing dipolar coupling between negatively charged NV$^{\text -}$ centers. Such a scheme is of interest for NV$^\text{-}$ magnetometers which have reached the NV$^\text{-}$-NV$^\text{-}$ coupling limit. We discuss experimental implementation in NV ensembles, as well as applicability of the current approach to more general spin bath decoupling and superconducting qubit control.

quant-ph

Ultralong Dephasing Times in Solid-State Spin Ensembles via Quantum Control

Quantum spin dephasing is caused by inhomogeneous coupling to the environment, with resulting limits to the measurement time and precision of spin-based sensors. The effects of spin dephasing can be especially pernicious for dense ensembles of electronic spins in the solid-state, such as for nitrogen-vacancy (NV) color centers in diamond. We report the use of two complementary techniques, spin bath control and double quantum coherence, to enhance the inhomogeneous spin dephasing time ($T_2^*$) for NV ensembles by more than an order of magnitude. In combination, these quantum control techniques (i) eliminate the effects of the dominant NV spin ensemble dephasing mechanisms, including crystal strain gradients and dipolar interactions with paramagnetic bath spins, and (ii) increase the effective NV gyromagnetic ratio by a factor of two. Applied independently, spin bath control and double quantum coherence elucidate the sources of spin dephasing over a wide range of NV and spin bath concentrations. These results demonstrate the longest reported $T_2^*$ in a solid-state electronic spin ensemble at room temperature, and outline a path towards NV-diamond magnetometers with broadband femtotesla sensitivity.

quant-ph

Simultaneous Broadband Vector Magnetometry Using Solid-State Spins

We demonstrate a vector magnetometer that simultaneously measures all Cartesian components of a dynamic magnetic field using an ensemble of nitrogen-vacancy (NV) centers in a single-crystal diamond. Optical NV-diamond measurements provide high-sensitivity, broadband magnetometry under ambient or extreme physical conditions; and the fixed crystallographic axes inherent to this solid-state system enable vector sensing free from heading errors. In the present device, multi-channel lock-in detection extracts the magnetic-field-dependent spin resonance shifts of NVs oriented along all four tetrahedral diamond axes from the optical signal measured on a single detector. The sensor operates from near DC up to a $12.5$ kHz measurement bandwidth; and simultaneously achieves $\sim\!50$ pT/$\sqrt{\text{Hz}}$ magnetic field sensitivity for each Cartesian component, which is to date the highest demonstrated sensitivity of a full vector magnetometer employing solid-state spins. Compared to optimized devices interrogating the four NV orientations sequentially, the simultaneous vector magnetometer enables a $4\times$ measurement speedup. This technique can be extended to pulsed-type sensing protocols and parallel wide-field magnetic imaging.

quant-ph

Mapping the Microscale Origins of MRI Contrast with Subcellular NV Diamond Magnetometry

Magnetic resonance imaging (MRI) is a widely used biomedical imaging modality that derives much of its contrast from microscale magnetic field gradients in biological tissues. However, the connection between these sub-voxel field patterns and MRI contrast has not been studied experimentally. Here, we describe a new method to map subcellular magnetic fields in mammalian cells and tissues using nitrogen vacancy diamond magnetometry and connect these maps to voxel-scale MRI contrast, providing insights for in vivo imaging and contrast agent design.

physics.med-ph

In-vacuum scattered light reduction with cupric oxide surfaces for sensitive fluorescence detection

We demonstrate a simple and easy method for producing low-reflectivity surfaces that are ultra-high vacuum compatible, may be baked to high temperatures, and are easily applied even on complex surface geometries. Black cupric oxide (CuO) surfaces are chemically grown in minutes on any copper surface, allowing for low-cost, rapid prototyping and production. The reflective properties are measured to be comparable to commercially available products for creating optically black surfaces. We describe a vacuum apparatus which uses multiple blackened copper surfaces for sensitive, low-background detection of molecules using laser-induced fluorescence.

physics.ins-det