SearcharxivSearch

arXiv subjects

John Kitching

Publications and source records attributed to John Kitching.

At least 19 recordsLinked to original sources

Controlling light shifts in chip-scale atomic beam clocks

Chip-scale atomic beam clocks are being investigated to extend the range of clock stability achievable in low-power timing applications. Here, we demonstrate a centimeter-scale, Ramsey coherent population trapping (CPT) clock based on a microfabricated Cs atomic beam device and investigate the interplay between light shifts and Doppler shifts that determines its leading clock systematics. We show that these shifts exhibit competing dependencies on CPT light parameters, leading to ``doubly-insensitive" operating points where the clock frequency is simultaneously insensitive to laser frequency and power. We further demonstrate a method for controlling key clock shifts using spectroscopic signatures from the atomic beam that is compatible with fully-integrated operation. The clock achieves a fractional frequency stability of $2 \times 10^{-10}$ at $1~\textrm{s}$ and sub-$\mu$s drift over nearly $17~\textrm{hours}$, with leading CPT light systematics controlled below the $10^{-12}$ level.

physics.atom-ph

Wafer-Scale Micro-Knife Sealed Vacuum Cells for Quantum Devices

Advanced integration technologies greatly enhance the prospects and reliability of practical quantum sensors, atomic clocks, and quantum information technologies. The performance and proliferation of these devices at chip-scale is contingent upon developing low leak and low gas permeation vacuum cells using wafer-scale techniques. Here we demonstrate both evacuated atomic beam cells and atomic vapor cells using plastic deformation micro-knife bonding of selectively etched fused silica wafers. The cells are characterized using saturated absorption spectroscopy and fluorescence measurements. Vapor cells are mechanically robust exhibiting sheer-force strength ($\sim 15$MPa), demonstrate long lifetimes ($> 1$ year), low residual gas pressures $ (\ll 10^{-3} \, \text{mbar}) $, and leak rates below fine-leak testing sensitivity ($\ll 2.8 \times 10^{-10} \frac{\text{mBar} \cdot \text{L}}{\text{s}}$). Micro-knife bonding greatly simplifies the fabrication process for complex chip scale atom-beam devices and atomic vapor cells while identifying a path to future chip-scale cold atom devices, improved chip scale atomic clocks, and fieldable dissipation-dilution-limited optomechanics.

physics.atom-ph

Doppler Shift Mitigation in a Chip-Scale Atomic Beam Clock

Chip-scale microwave atomic systems based on thermal atomic beams offer a promising approach to realize low-power and low-drift clocks for timing holdover applications. Miniature beam clocks are expected to suppress many of the shifts that commonly limit existing chip-scale atomic clocks based on coherent population trapping, including collisional shifts and some light shifts. However, the beam geometry can amplify some challenges such as Doppler shifts, which generate a strong sensitivity to laser frequency variation. Using a cm-scale 87Rb atom beam clock, we identify a surprisingly strong competition between Doppler shifts and resonant light shifts arising from asymmetric decay in the clock spectroscopy {\Lambda}-system. Leveraging this competition between Doppler and resonant light shifts, we demonstrate clock operation at specific, convenient experimental parameters consistent with zero sensitivity to laser frequency variation and white-noise-limited clock frequency averaging for 1000 s of integration.

physics.atom-ph

Active compensation of the AC Stark shift in a two-photon rubidium optical frequency reference using power modulation

We implement a feedback protocol to suppress the AC Stark shift in a two-photon rubidium optical frequency reference, reducing its sensitivity to optical power variations by a factor of 1000. This method alleviates the tradeoff between short-term and long-term stability imposed by the AC Stark shift, enabling us to simultaneously achieve instabilities of $3\times10^{-14}$ at 1 s and $2\times10^{-14}$ at $10^4$ s. We also quantitatively describe, and experimentally explore, a stability limit imposed on clocks using this method by frequency noise on the local oscillator.

physics.app-ph

Light shift suppression in a CPT magnetometer using linear polarization and double frequency interrogation

We demonstrate a suppression of the light shift in a Coherent-Population-Trapping (CPT) atomic magnetometer by using linearly polarized light and a differential measurement between magnetic resonances. The radio frequency that creates the optical sidebands for CPT quickly switches between two magnetic sensitive transitions and the magnetic field is extrapolated from the difference of the center frequencies of the magnetic resonances. Light shifts and common drifts like collisional shifts can be suppressed through careful choice of measured resonances and we show the light shift reduction by more than a factor of 20 compared to excitation with circular polarized light. Various limitations to the method are discussed.

physics.atom-ph

Sub-Doppler spectroscopy of the strontium intercombination line in a microfabricated vapor cell

We report a 100 kHz linewidth for the 1S0 to 3P1 intercombination line of 88Sr atoms at 689nm in a microfabricated 9x14 x4.4 mm3 vapor cell. This puts an upper bound on the residual gas pressure in the vapor cell of 10 mTorr. The microfabricatd Sr vapor cell offers an inexpensive and scalable way to lock lasers in state-of-the-art cold-atom based atomic clocks and quantum computing experiments. It also paves the way for a compact and precise optical frequency references based on alkaline earth vapor cells.

physics.atom-ph

Wavefront Mapping for Absolute Atom Interferometry

Wavefront distortions are a leading source of systematic uncertainty in light-pulse atom interferometry, limiting absolute measurements of gravitational acceleration at the 30 nm/s$^2$ level. Here, we demonstrate in situ spatially resolved measurement of the interferometer phase in a Mach-Zehnder atom interferometer as a tool to characterize and correct wavefront bias. By introducing controllable curvature of the Raman light using an adjustable collimation retro-reflector, we show that the bias due to parabolic wavefront curvature can be measured with 1 mrad uncertainty and that finite-size corrections impact the measured phase curvature. This measurement process could be adopted in optimized atom interferometer gravimeters to reduce wavefront bias uncertainty below the nm/s$^2$ level.

physics.atom-ph

A chip-scale atomic beam source for non-classical light

Room temperature thermal atoms have proven to be a powerful resource for magnetometry, electrometry, atom-entanglement generation, and robust atomic clocks. Recent efforts have sought to realize compact and highly manufacturable atomic vapors and atomic beams for chip-scale magnetometry and atomic clocks. Here, we show that a chip-scale rubidium beam source can be integrated with a high finesse cavity-QED system to generate non-classical light. By demonstrating the compatibility of these two technologies, we open a new path for distributed sources of non-classical light and set the stage for using cavity-QED to enhance the performance of chip-scale magnetometers and atomic clocks.

physics.atom-ph

Chip-scale sub-Doppler atomic spectroscopy enabled by a metasurface integrated photonic emitter

We demonstrate chip-scale sub-Doppler spectroscopy in an integrated and fiber-coupled photonic-metasurface device. The device is a stack of three planar components: a photonic mode expanding grating emitter circuit with a monolithically integrated tilt compensating dielectric metasurface, a microfabricated atomic vapor cell and a mirror. The metasurface photonic circuit efficiently emits a 130 micrometer-wide $1/e^2$ diameter) collimated surface-normal beam with only -6.3 dB loss and couples the reflected beam back into the connecting fiber, requiring no alignment between the stacked components. We develop a simple model based on light propagation through the photonic device to interpret the atomic spectroscopy signals and explain spectral features covering the full Rb hyperfine state manifold.

physics.optics

Wafer-scale fabrication of evacuated alkali vapor cells

We describe a process for fabricating a wafer-scale array of alkali metal vapor cells with low residual gas pressure. We show that by etching long, thin channels between the cells on the Si wafer surface, the residual gas pressure in the evacuated vapor cell can be reduced to below 0.5 kPa (4 Torr) with a yield above 50 %. The low residual gas pressure in these mass-producible alkali vapor cells can enable a new generation of low-cost chip-scale atomic devices such as vapor cell optical clocks, wavelength references, and Rydberg sensors.

physics.app-ph

A chip-scale atomic beam clock

Atomic beams are a longstanding technology for atom-based sensors and clocks with widespread use in commercial frequency standards. Here, we report the demonstration a chip-scale microwave atomic beam clock using coherent population trapping (CPT) interrogation in a passively pumped atomic beam device. The beam device consists of a hermetically sealed vacuum cell fabricated from an anodically bonded stack of glass and Si wafers. Atomic beams are created using a lithographically defined microcapillary array connected to a Rb reservoir1 and propagate in a 15 mm long drift cavity. We present a detailed characterization of the atomic beam performance (total Rb flux $\approx 7.7 \times 10^{11} s^{-1}$ at 363 K device temperature) and of the vacuum environment in the device (pressure < 1 Pa), which is sustained using getter materials which pump residual gases and Rb vapor. A chip-scale beam clock is realized using Ramsey CPT spectroscopy of the 87Rb ground state hyperfine transition over a 10 mm Ramsey distance in the atomic beam device. The prototype atomic beam clock demonstrates a fractional frequency stability of $\approx 1.2 \times 10^{-9}/\sqrt{\tau}$ for integration times $\tau$ from 1 s to 250 s, limited by detection noise. Optimized atomic beam clocks based on this approach may exceed the long-term stability of existing chip-scale clocks, and leading long-term systematics are predicted to limit the ultimate fractional frequency stability below $10^{-12}$.

physics.atom-ph

Electromagnetically induced transparency based Rydberg-atom sensor for quantum voltage measurements

We investigate the Stark shift in Rydberg rubidium atoms through electromagnetically induced transparency for the measurement of direct current (dc) and 60~Hz alternating current (ac) voltages. This technique has direct applications to atom-based measurements of dc and ac voltage and the calibration of voltage instrumentation. We present experimental results for different atomic states that allow for dc and ac voltage measurements ranging from 0~V to 12~V. A Rydberg atom-based voltage standard could become an alternative calibration method with more favorable size, weight, power consumption, and cost compared to the more precise Josephson voltage standard. In this study, we also demonstrate how the voltage measurements can be utilized to determine the atomic polarizability for the Rydberg states. The Rydberg atom-based voltage measurement technology would become a complimentary method for dissemination of the voltage scale directly to the end user.

physics.atom-ph

High-performance, compact optical standard

We describe a high-performance, compact optical frequency standard based on a microfabricated Rb vapor cell and a low-noise, external cavity diode laser operating on the Rb two-photon transition at 778 nm. The optical standard achieves an instability of 1.8x10$^{-13}$/$\sqrt{\tau}$ for times less than 100 s and a flicker noise floor of 1x10$^{-14}$ out to 6000 s. At long integration times, the instability is limited by variations in optical probe power and the AC Stark shift. The retrace was measured to 5.7x10$^{-13}$ after 30 hours of dormancy. Such a simple, yet high-performance optical standard could be suitable as an accurate realization of the SI meter or, if coupled with an optical frequency comb, as a compact atomic clock comparable to a hydrogen maser.

physics.atom-ph

Enhanced observation time of magneto-optical traps using micro-machined non-evaporable getter pumps

We show that micro-machined non-evaporable getter pumps (NEGs) can extend the time over which laser cooled atoms canbe produced in a magneto-optical trap (MOT), in the absence of other vacuum pumping mechanisms. In a first study, weincorporate a silicon-glass microfabricated ultra-high vacuum (UHV) cell with silicon etched NEG cavities and alumino-silicateglass (ASG) windows and demonstrate the observation of a repeatedly-loading MOT over a 10 minute period with a single laser-activated NEG. In a second study, the capacity of passive pumping with laser activated NEG materials is further investigated ina borosilicate glass-blown cuvette cell containing five NEG tablets. In this cell, the MOT remained visible for over 4 days withoutany external active pumping system. This MOT observation time exceeds the one obtained in the no-NEG scenario by almostfive orders of magnitude. The cell scalability and potential vacuum longevity made possible with NEG materials may enable inthe future the development of miniaturized cold-atom instruments.

physics.atom-ph

Robust inertial sensing with point-source atom interferometry for interferograms spanning a partial period

Point source atom interferometry (PSI) uses the velocity distribution in a cold atom cloud to simultaneously measure one axis of acceleration and two axes of rotation from the phase, orientation, and period of atomic interference fringe images. For practical applications in inertial sensing and precision measurement, it is important to be able to measure a wide range of system rotation rates, corresponding to interferograms with far less than one full interference fringe to very many fringes. The interferogram analysis techniques used previously for PSI are not sensitive to low rotation rates, which generates less one full interference fringe across the cloud, limiting the dynamic range of the instrument. We introduce an experimental method, new to atom interferometry and closely related to optical phase-shifting interferometry, that is effective in extracting rotation values from signals consisting of fractional fringes as well as many fringes without prior knowledge of the rotation rate. Our method uses four interferograms, each with a controlled Raman laser phase shift, to reconstruct the underlying atomic interferometer phase map.

physics.atom-ph

Miniaturized optical frequency standard for next-generation portable optical clocks

Optical frequency standards, lasers stabilized to atomic or molecular transitions, are widely used in length metrology and laser ranging, provide a backbone for optical communications and lie at the heart of next-generation optical atomic clocks. Here we demonstrate a compact, low-power optical frequency standard based on the Doppler-free, two-photon transition in rubidium-87 at 778 nm implemented on a micro-optics breadboard. The optical standard achieves a fractional frequency stability of 2.9x10$^{-12}$/$\sqrt{\tau}$ for averaging times $\tau$ less than 10$^{3}$ s, has a volume of $\approx$35 cm$^3$ and operates on $\approx$450 mW of electrical power. These results demonstrate a key step towards the development of compact optical clocks and the broad dissemination of SI-traceable wavelength references.

physics.atom-ph

Ultranarrow linewidth photonic-atomic laser

Lasers with high spectral purity can enable a diverse application space, including precision spectroscopy, coherent high-speed communications, physical sensing, and manipulation of quantum systems. Already, meticulous design and construction of bench Fabry-Perot cavities has made possible dramatic achievements in active laser-linewidth reduction, predominantly for optical-atomic clocks. Yet there is increasing demand for miniaturized laser systems operating with high performance in ambient environments. Here, we report a compact and robust photonic-atomic laser comprising a 2.5 cm long, 20,000 finesse, monolithic Fabry-Perot cavity integrated with a micromachined rubidium vapor cell. By leveraging the short-time frequency stability of the cavity and the long-time frequency stability of atoms, we realize an ultranarrow-linewidth laser that enables integration for extended measurements. Specifically, our laser supports a fractional-frequency stability of $1\times 10^{-13}$ at an averaging time of 20 ms, $7 \times 10^{-13}$ at 300 s, an integrated linewidth of 25 Hz that results from thermal noise, a Lorentzian linewidth as low as 0.06 Hz$^2$/Hz, and a passive vibration immunity as low as $10^{-10}$/g. Our work explores hybrid laser systems with monolithic photonic and atomic packages based on physical design.

physics.optics

Direct Kerr-frequency-comb atomic spectroscopy

Microresonator-based soliton frequency combs - microcombs - have recently emerged to offer low-noise, photonic-chip sources for optical measurements. Owing to nonlinear-optical physics, microcombs can be built with various materials and tuned or stabilized with a consistent framework. Some applications require phase stabilization, including optical-frequency synthesis and measurements, optical-frequency division, and optical clocks. Partially stabilized microcombs can also benefit applications, such as oscillators, ranging, dual-comb spectroscopy, wavelength calibration, and optical communications. Broad optical bandwidth, brightness, coherence, and frequency stability have made frequency-comb sources important for studying comb-matter interactions with atoms and molecules. Here, we explore direct microcomb atomic spectroscopy, utilizing a cascaded, two-photon 1529-nm atomic transition of rubidium. Both the microcomb and the atomic vapor are implemented with planar fabrication techniques to support integration. By fine and simultaneous control of the repetition rate and carrier-envelope-offset frequency of the soliton microcomb, we obtain direct sub-Doppler and hyperfine spectroscopy of the $4^2D_{5/2}$ manifold. Moreover, the entire set of microcomb modes are stabilized to this atomic transition, yielding absolute optical-frequency fluctuations of the microcomb at the kilohertz-level over a few seconds and < 1 MHz day-to-day accuracy. Our work demonstrates atomic spectroscopy with microcombs and provides a rubidium-stabilized microcomb laser source, operating across the 1550 nm band for sensing, dimensional metrology, and communication.

physics.optics