SearcharxivSearch

arXiv subjects

John M. Robinson

Publications and source records attributed to John M. Robinson.

15 recordsLinked to original sources

Experimental Demonstration of Logical Magic State Distillation

Realizing universal fault-tolerant quantum computation is a key goal in quantum information science. By encoding quantum information into logical qubits utilizing quantum error correcting codes, physical errors can be detected and corrected, enabling substantial reduction in logical error rates. However, the set of logical operations that can be easily implemented on such encoded qubits is often constrained, necessitating the use of special resource states known as 'magic states' to implement universal, classically hard circuits. A key method to prepare high-fidelity magic states is to perform 'distillation', creating them from multiple lower fidelity inputs. Here we present the experimental realization of magic state distillation with logical qubits on a neutral-atom quantum computer. Our approach makes use of a dynamically reconfigurable architecture to encode and perform quantum operations on many logical qubits in parallel. We demonstrate the distillation of magic states encoded in d=3 and d=5 color codes, observing improvements of the logical fidelity of the output magic states compared to the input logical magic states. These experiments demonstrate a key building block of universal fault-tolerant quantum computation, and represent an important step towards large-scale logical quantum processors.

quant-ph

Excess noise and photo-induced effects in highly reflective crystalline mirror coatings

Thermodynamically induced length fluctuations of high-reflectivity mirror coatings put a fundamental limit on sensitivity and stability of precision optical interferometers like gravitational wave detectors and ultra-stable lasers. The main contribution - Brownian thermal noise - is related to the mechanical loss of the coating material. Owing to their low mechanical losses, Al\textsubscript{0.92}Ga\textsubscript{0.08}As/GaAs crystalline mirror coatings are expected to reduce this limit. At room temperature they have demonstrated lower Brownian thermal noise than with conventional amorphous coatings. %However, no detailed study on the noise constituents from these coatings in optical interferometers has been conducted. We present a detailed study on the spatial and temporal noise properties of such coatings by using them in two independent cryogenic silicon optical Fabry-Perot resonators operated at 4 K, 16 K and 124 K. We confirm the expected low Brownian thermal noise, but also discover two new noise sources that exceed the Brownian noise: birefringent noise that can be canceled via polarization averaging and global excess noise (10 dB above Brownian noise). These new noise contributions are a barrier to improving ultra-stable lasers and the related performance of atomic clocks, and potentially limit the sensitivity of third-generation gravitational wave detectors. Hence, they must be considered carefully in precision interferometry experiments using similar coatings based on semiconductor materials.

physics.optics

Realizing spin squeezing with Rydberg interactions in a programmable optical clock

Neutral-atom arrays trapped in optical potentials are a powerful platform for studying quantum physics, combining precise single-particle control and detection with a range of tunable entangling interactions. For example, these capabilities have been leveraged for state-of-the-art frequency metrology as well as microscopic studies of entangled many-particle states. In this work, we combine these applications to realize spin squeezing - a widely studied operation for producing metrologically useful entanglement - in an optical atomic clock based on a programmable array of interacting optical qubits. In this first demonstration of Rydberg-mediated squeezing with a neutral-atom optical clock, we generate states that have almost 4 dB of metrological gain. Additionally, we perform a synchronous frequency comparison between independent squeezed states and observe a fractional frequency stability of $1.087(1)\times 10^{-15}$ at one-second averaging time, which is 1.94(1) dB below the standard quantum limit, and reaches a fractional precision at the $10^{-17}$ level during a half-hour measurement. We further leverage the programmable control afforded by optical tweezer arrays to apply local phase shifts in order to explore spin squeezing in measurements that operate beyond the relative coherence time with the optical local oscillator. The realization of this spin-squeezing protocol in a programmable atom-array clock opens the door to a wide range of quantum-information inspired techniques for optimal phase estimation and Heisenberg-limited optical atomic clocks.

quant-ph

Frequency stability of cryogenic silicon cavities with semiconductor crystalline coatings

State-of-the-art optical oscillators employing cryogenic reference cavities are limited in performance by the Brownian thermal noise associated with the mechanical dissipation of the mirror coatings. Recently, crystalline Al$_{1-x}$Ga$_{x}$As/GaAs coatings have emerged as a promising candidate for improved coating thermal noise. We present measurements of the frequency noise of two fully crystalline cryogenic reference cavities with Al$_{0.92}$Ga$_{0.08}$As/GaAs optical coatings. We report on previously unmeasured birefringent noise associated with anti-correlated frequency fluctuations between the polarization modes of the crystalline coatings, and identify variables that affect its magnitude. Comparing the birefringent noise between the two cryogenic reference cavities reveals a phenomenological set of scalings with intracavity power and mode area. We implement an interrogation scheme that cancels this noise by simultaneous probing of both polarization modes. The residual noise remaining after this cancellation is larger than both cavities thermal noise limits, but still lower than the instabilities previously measured on equivalent resonators with dielectric coatings. Though the source of these novel noise mechanisms is unclear, we demonstrate that crystalline coatings can provide stability and sensitivity competitive with resonators employing dielectric coatings.

physics.optics

Resolving the gravitational redshift within a millimeter atomic sample

Einstein's theory of general relativity states that clocks at different gravitational potentials tick at different rates - an effect known as the gravitational redshift. As fundamental probes of space and time, atomic clocks have long served to test this prediction at distance scales from 30 centimeters to thousands of kilometers. Ultimately, clocks will study the union of general relativity and quantum mechanics once they become sensitive to the finite wavefunction of quantum objects oscillating in curved spacetime. Towards this regime, we measure a linear frequency gradient consistent with the gravitational redshift within a single millimeter scale sample of ultracold strontium. Our result is enabled by improving the fractional frequency measurement uncertainty by more than a factor of 10, now reaching 7.6$\times 10^{-21}$. This heralds a new regime of clock operation necessitating intra-sample corrections for gravitational perturbations.

physics.atom-ph

Optical Atomic Clock Comparison through Turbulent Air

We use frequency comb-based optical two-way time-frequency transfer (O-TWTFT) to measure the optical frequency ratio of state-of-the-art ytterbium and strontium optical atomic clocks separated by a 1.5 km open-air link. Our free-space measurement is compared to a simultaneous measurement acquired via a noise-cancelled fiber link. Despite non-stationary, ps-level time-of-flight variations in the free-space link, ratio measurements obtained from the two links, averaged over 30.5 hours across six days, agree to $6\times10^{-19}$, showing that O-TWTFT can support free-space atomic clock comparisons below the $10^{-18}$ level.

physics.optics

Precision Metrology Meets Cosmology: Improved Constraints on Ultralight Dark Matter from Atom-Cavity Frequency Comparisons

We conduct frequency comparisons between a state-of-the-art strontium optical lattice clock, a cryogenic crystalline silicon cavity, and a hydrogen maser to set new bounds on the coupling of ultralight dark matter to Standard Model particles and fields in the mass range of $10^{-16}$ $-$ $10^{-21}$ eV. The key advantage of this two-part ratio comparison is the differential sensitivities to time variation of both the fine-structure constant and the electron mass, achieving a substantially improved limit on the moduli of ultralight dark matter, particularly at higher masses than typical atomic spectroscopic results. Furthermore, we demonstrate an extension of the search range to even higher masses by use of dynamical decoupling techniques. These results highlight the importance of using the best performing atomic clocks for fundamental physics applications as all-optical timescales are increasingly integrated with, and will eventually supplant, existing microwave timescales.

physics.atom-ph

Frequency Ratio Measurements with 18-digit Accuracy Using a Network of Optical Clocks

Atomic clocks occupy a unique position in measurement science, exhibiting higher accuracy than any other measurement standard and underpinning six out of seven base units in the SI system. By exploiting higher resonance frequencies, optical atomic clocks now achieve greater stability and lower frequency uncertainty than existing primary standards. Here, we report frequency ratios of the $^{27}$Al$^+$, $^{171}$Yb and $^{87}$Sr optical clocks in Boulder, Colorado, measured across an optical network spanned by both fiber and free-space links. These ratios have been evaluated with measurement uncertainties between $6\times10^{-18}$ and $8\times10^{-18}$, making them the most accurate reported measurements of frequency ratios to date. This represents a critical step towards redefinition of the SI second and future applications such as relativistic geodesy and tests of fundamental physics.

physics.atom-ph

Demonstration of a time scale based on a stable optical carrier

We demonstrate a time scale based on a phase stable optical carrier that accumulates an estimated time error of $48\pm94$ ps over 34 days of operation. This all-optical time scale is formed with a cryogenic silicon cavity exhibiting improved long-term stability and an accurate $^{87}$Sr lattice clock. We show that this new time scale architecture outperforms existing microwave time scales, even when they are steered to optical frequency standards. Our analysis indicates that this time scale is capable of reaching a stability below $1\times10^{-17}$ after a few months of averaging, making timekeeping at the $10^{-18}$ level a realistic prospect.

physics.atom-ph

JILA SrI Optical Lattice Clock with Uncertainty of $2.0 \times 10^{-18}$

We report on an improved systematic evaluation of the JILA SrI optical lattice clock, achieving a nearly identical systematic uncertainty compared to the previous strontium accuracy record set by the JILA SrII optical lattice clock (OLC) at $2.1 \times 10^{-18}$. This improves upon the previous evaluation of the JILA SrI optical lattice clock in 2013, and we achieve a more than twenty-fold reduction in systematic uncertainty to $2.0 \times 10^{-18}$. A seven-fold improvement in clock stability, reaching $4.8 \times 10^{-17}/\sqrtτ$ for an averaging time $τ$ in seconds, allows the clock to average to its systematic uncertainty in under 10 minutes. We improve the systematic uncertainty budget in several important ways. This includes a novel scheme for taming blackbody radiation-induced frequency shifts through active stabilization and characterization of the thermal environment, inclusion of higher-order terms in the lattice light shift, and updated atomic coefficients. Along with careful control of other systematic effects, we achieve low temporal drift of systematic offsets and high uptime of the clock. We additionally present an improved evaluation of the second order Zeeman coefficient that is applicable to all Sr optical lattice clocks. These improvements in performance have enabled several important studies including frequency ratio measurements through the Boulder Area Clock Optical Network (BACON), a high precision comparison with the JILA 3D lattice clock, a demonstration of a new all-optical time scale combining SrI and a cryogenic silicon cavity, and a high sensitivity search for ultralight scalar dark matter.

physics.atom-ph

Crystalline optical cavity at 4 K with thermal noise limited instability and ultralow drift

Crystalline optical cavities are the foundation of today's state-of-the-art ultrastable lasers. Building on our previous silicon cavity effort, we now achieve the fundamental thermal noise-limited stability for a 6 cm long silicon cavity cooled to 4 Kelvin, reaching $6.5\times10^{-17}$ from 0.8 to 80 seconds. We also report for the first time a clear linear dependence of the cavity frequency drift on the incident optical power. The lowest fractional frequency drift of $-3\times10^{-19}$/s is attained at a transmitted power of 40 nW, with an extrapolated drift approaching zero in the absence of optical power. These demonstrations provide a promising direction to reach a new performance domain for stable lasers, with stability better than $1\times10^{-17}$ and fractional linear drift below $1\times10^{-19}$/s.

physics.ins-det

Frequency measurements of superradiance from the strontium clock transition

We present the first characterization of the spectral properties of superradiant light emitted from the ultra-narrow, 1 mHz linewidth optical clock transition in an ensemble of cold $^{87}$Sr atoms. Such a light source has been proposed as a next-generation active atomic frequency reference, with the potential to enable high-precision optical frequency references to be used outside laboratory environments. By comparing the frequency of our superradiant source to that of a state-of-the-art cavity-stabilized laser and optical lattice clock, we observe a fractional Allan deviation of $6.7(1)\times 10^{-16}$ at 1 second of averaging, establish absolute accuracy at the 2 Hz ($4\times 10^{-15}$ fractional frequency) level, and demonstrate insensitivity to key environmental perturbations.

physics.atom-ph

The cardiac Ca-sensitive regulatory switch, a system in dynamic equilibrium

The Ca-sensitive regulatory switch of cardiac muscle is a paradigmatic example of protein assemblies that communicate ligand binding through allosteric change. The switch is a dimeric complex of troponin C (TnC), an allosteric sensor for Ca, and troponin I (TnI), an allosteric reporter. Time-resolved equilibrium FRET measurements suggest that the switch activates in two steps: a TnI-independent Ca-priming step followed by TnI-dependent opening. To resolve the mechanistic role of TnI in activation we performed stopped-flow FRET measurements of activation following rapid addition of a lacking component (Ca or TnI) and deactivation following rapid chelation of Ca. The time-resolved measurements, stopped-flow measurements, and Ca-titration measurements were globally analyzed in terms of a new quantitative dynamic model of TnC-TnI allostery. The analysis provided a mesoscopic parameterization of distance changes, free energy changes, and transition rates among the accessible coarse-grained states of the system. The results reveal (i) the Ca-induced priming step, which precedes opening, is the rate limiting step in activation, (ii) closing is the rate limiting step in deactivation, (iii) TnI induces opening, (iv) an incompletely deactivated population when regulatory Ca is not bound, which generates an accessory pathway of activation, and (v) incomplete activation by Ca--when regulatory Ca is bound, a 3:2 mixture of dynamically inter-converting open (active) and primed-closed (partially active) conformers is observed (15 C). Temperature-dependent stopped-flow FRET experiments provide a near complete thermo-kinetic parametrization of opening.

q-bio.BM

Physical limits on computation by assemblies of allosteric proteins

Assemblies of allosteric proteins, nano-scale Brownian computers, are the principle information processing devices in biology. The troponin C-troponin I (TnC-TnI) complex, the Ca$^{2+}$-sensitive regulatory switch of the heart, is a paradigm for Brownian computation. TnC and TnI specialize in sensing (reading) and reporting (writing) tasks of computation. We have examined this complex using a newly developed phenomenological model of allostery. Nearest-neighbor-limited interactions among members of the assembly place previously unrecognized constrains the topology of the system's free energy landscape and generate degenerate transition probabilities. As a result, signaling fidelity and deactivation kinetics can not be simultaneously optimized. This trade-off places an upper limit on the rate of information processing by assemblies of allosteric proteins that couple to a single ligand chemical bath.

cond-mat.soft

Equality statements for entropy change in open systems

The entropy change of a (non-equilibrium) Markovian ensemble is calculated from (1) the ensemble phase density $p(t)$ evolved as iterative map, $p(t) = \mathbb{M}(t) p(t- Δt)$ under detail balanced transition matrix $\mathbb{M}(t)$, and (2) the invariant phase density $π(t) = \mathbb{M}(t)^{\infty} π(t) $. A virtual measurement protocol is employed, where variational entropy is zero, generating exact expressions for irreversible entropy change in terms of the Jeffreys measure, $\mathcal{J}(t) = \sum_Γ [p(t) - π(t)] \ln \bfrac{p(t)}{π(t)}$, and for reversible entropy change in terms of the Kullbach-Leibler measure, $\mathcal{D}_{KL}(t) = \sum_Γ π(0) \ln \bfrac{π(0)}{π(t)}$. Five properties of $\mathcal{J}$ are discussed, and Clausius' theorem is derived.

cond-mat.stat-mech