SearcharxivSearch

arXiv subjects

John W. Garrett

Publications and source records attributed to John W. Garrett.

2 recordsLinked to original sources

From Embeddings to Accuracy: Comparing Foundation Models for Radiographic Classification

Foundation models provide robust embeddings for diverse tasks, including medical imaging. We evaluate embeddings from seven general and medical-specific foundation models (e.g., DenseNet121, BiomedCLIP, MedImageInsight, Rad-DINO, CXR-Foundation) for training lightweight adapters in multi-class radiography classification. Using a dataset of 8,842 radiographs across seven classes, we trained adapters with algorithms like K-Nearest Neighbors, logistic regression, SVM, random forest, and MLP. The combination of MedImageInsight embeddings with an SVM or MLP adapter achieved the highest mean area under the curve (mAUC) of 93.1%. This performance was statistically superior to other models, including MedSigLIP with an MLP (91.0%), Rad-DINO with an SVM (90.7%), and CXR-Foundation with logistic regression (88.6%). In contrast, models like BiomedCLIP (82.8%) and Med-Flamingo (78.5%) showed lower performance. Crucially, these lightweight adapters are computationally efficient, training in minutes and performing inference in seconds on a CPU, making them practical for clinical use. A fairness analysis of the top-performing MedImageInsight adapter revealed minimal performance disparities across patient gender (within 1.8%) and age groups (std. dev < 1.4%), with no significant statistical differences. These findings confirm that embeddings from specialized foundation models, particularly MedImageInsight, can power accurate, efficient, and equitable diagnostic tools using simple, lightweight adapters.

cs.CV

A Generalizable Artificial Intelligence Model for COVID-19 Classification Task Using Chest X-ray Radiographs: Evaluated Over Four Clinical Datasets with 15,097 Patients

Purpose: To answer the long-standing question of whether a model trained from a single clinical site can be generalized to external sites. Materials and Methods: 17,537 chest x-ray radiographs (CXRs) from 3,264 COVID-19-positive patients and 4,802 COVID-19-negative patients were collected from a single site for AI model development. The generalizability of the trained model was retrospectively evaluated using four different real-world clinical datasets with a total of 26,633 CXRs from 15,097 patients (3,277 COVID-19-positive patients). The area under the receiver operating characteristic curve (AUC) was used to assess diagnostic performance. Results: The AI model trained using a single-source clinical dataset achieved an AUC of 0.82 (95% CI: 0.80, 0.84) when applied to the internal temporal test set. When applied to datasets from two external clinical sites, an AUC of 0.81 (95% CI: 0.80, 0.82) and 0.82 (95% CI: 0.80, 0.84) were achieved. An AUC of 0.79 (95% CI: 0.77, 0.81) was achieved when applied to a multi-institutional COVID-19 dataset collected by the Medical Imaging and Data Resource Center (MIDRC). A power-law dependence, N^(k )(k is empirically found to be -0.21 to -0.25), indicates a relatively weak performance dependence on the training data sizes. Conclusion: COVID-19 classification AI model trained using well-curated data from a single clinical site is generalizable to external clinical sites without a significant drop in performance.

eess.IV