SearcharxivSearch

arXiv subjects

Johnathon Gard

Publications and source records attributed to Johnathon Gard.

8 recordsLinked to original sources

Design of a mission to measure the shape and substructure of the 511 keV gamma-ray line from the center of the Milky Way

The 511 keV electron-positron annihilation feature near the galactic center has been detected for more than half a century, yet its origin remains a mystery. In this paper, we describe a concept for a balloon-borne 511 keV $γ$-ray mission called the 511-Spectrometer Mission. The mission will use Transition-Edge Sensor (TES) arrays with thick metal absorbers that are thermally coupled to the TES. The strength of the approach is a projected energy resolution of 200 eV Full Width Half Maximum (FWHM) at 511 keV, enabling detailed studies of the shape and substructure of the 511 keV emission from the galactic center region. A first mission equipped with 8,192 $γ$-ray detectors and a fully active shield and collimator could detect the galactic center with ~35 $σ$ statistical significance. We present the mission concept as well as first results obtained with a prototype detector equipped with $1.35\times1.35\times2$ mm$^{3}$ Bi absorbers. The detector has a quantum efficiency of 15% for 511 keV photons in photoelectric effect interactions. In tests with a $^{137}$Cs source, these prototype detectors show an energy resolution of 525 eV FWHM at 662 keV. We end with a discussion of follow-up missions that use coded mask imaging, or use concentrating or focusing optics to scrutinize the sources of 511 keV $γ$-rays on smaller angular scales.

astro-ph.IM

Characterization of Silicon-Membrane TES Microcalorimeters for Large-Format X-ray Spectrometers with Integrated Microwave SQUID Readout

We present the electro-thermal characterization of transition-edge sensor (TES) detectors suspended on Si membranes fabricated using a silicon-on-insulator (SOI) wafer. The use of an all-silicon fabrication platform, in contrast to the more commonly used silicon nitride membranes, is compatible with monolithic fabrication of integrated TES and SQUID circuits. The all-silicon architecture additionally allows efficient use of focal plane area; the readout circuitry may be positioned out of the focal plane by bending a thinned portion of the chip. Compatibility with integrated fabrication and efficient use of focal plane area provide a path to an efficient soft X-ray spectrometer. This work is motivated by our goal to develop a 10,000-pixel TES spectrometer to overcome critical measurement limitations in catalysis research. The characterization of fragile, carbon-based intermediates via techniques like Resonant Inelastic X-ray Scattering (RIXS) is often precluded by the slow, high-flux nature of existing technologies. The new instrument will allow for fast RIXS measurements to be made without causing sample damage. We verify the detector models and measure the energy resolution using a pulsed optical laser, demonstrating the viability of this approach for the final instrument to be deployed at the National Synchrotron Light Source II (NSLS-II).

physics.ins-det

A high-speed, high-resolution Transition Edge Sensor spectrometer for soft X-rays at the Advanced Photon Source

This project explores the design and development of a transition edge sensor (TES) spectrometer for resonant soft X- ray scattering (RSXS) measurements developed in collaboration between Argonne National Laboratory (ANL) and the National Institute of Standards and Technology (NIST). Soft X-ray scattering is a powerful technique for studying the electronic and magnetic properties of materials on a microscopic level. However, the lack of high-performance soft X-ray spectrometers has limited the potential of this technique. TES spectrometers have the potential to overcome these limitations due to their high energy resolution, high efficiency, and broad energy range. This project aims to optimize the design of a TES spectrometer for RSXS measurements and more generally soft X-ray spectroscopy at the Advanced Photon Source (APS) 29-ID, leading to improved understanding of advanced materials. We will present a detailed description of the instrument design and implementation. The spectrometer consists of a large array of approximately 250 high-speed and high-resolution pixels. The pixels have saturation energies of approximately 1 keV, sub-ms pulse duration and energy resolution of approximately 1 eV. The array is read out using microwave multiplexing chips with MHz bandwidth per channel, enabling efficient data throughput. To facilitate measurement of samples in situ under ultra-high vacuum conditions at the beamline, the spectrometer is integrated with an approximately 1 m long snout.

physics.ins-det

System performance of a cryogenic test-bed for the time-division multiplexing readout for NewAthena X-IFU

The X-ray Integral Field Unit (X-IFU) is an instrument of ESA's future NewAthena space observatory, with the goal to provide high-energy resolution ($<$ 4 eV at X-ray energies up to 7 keV) and high-spatial resolution (9") spectroscopic imaging over the X-ray energy range from 200 eV to 12 keV, by means of an array of about 1500 transition-edge sensors (TES) read out via SQUID time-division multiplexing (TDM). A TDM-based laboratory test-bed has been assembled at SRON, hosting an array of $75\times 75\ \upmu$m$^2$ TESs that are read out via 2-column $\times$ 32-row TDM. A system component that is critical to high-performance operation is the wiring harness that connects the room-temperature electronics to the cryogenic readout componentry. We report here on our characterization of such a test-bed, whose harness has a length close to what envisioned for X-IFU, which allowed to achieve a co-added energy resolution at a level of 2.7~eV FWHM at 6~keV via 32-row readout. In addition, we provide an outlook on the integration of TDM readout into the X-IFU Focal-Plane Assembly Development Model.

astro-ph.IM

The 511-CAM Mission: A Pointed 511 keV Gamma-Ray Telescope with a Focal Plane Detector Made of Stacked Transition Edge Sensor Microcalorimeter Arrays

The 511 keV gamma-ray emission from the galactic center region may fully or partially originate from the annihilation of positrons from dark matter particles with electrons from the interstellar medium. Alternatively, the positrons could be created by astrophysical sources, involving exclusively standard model physics. We describe here a new concept for a 511 keV mission called 511-CAM (511 keV gamma-ray CAmera using Micro-calorimeters) that combines focusing gamma-ray optics with a stack of Transition Edge Sensor (TES) microcalorimeter arrays in the focal plane. The 511-CAM detector assembly has a projected 511 keV energy resolution of 390 eV Full Width Half Maximum (FWHM) or better, and improves by a factor of at least 11 on the performance of state-of-the-art Ge-based Compton telescopes. Combining this unprecedented energy resolution with sub-arcmin angular resolutions afforded by Laue lens or channeling optics could make substantial contributions to identifying the origin of the 511 keV emission by discovering and characterizing point sources and measuring line-of-sight velocities of the emitting plasmas.

astro-ph.IM

ASCENT - A balloon-borne hard X-ray imaging spectroscopy telescope using transition edge sensor microcalorimeter detectors

Core collapse supernovae are thought to be one of the main sources in the galaxy of elements heavier than iron. Understanding the origin of the elements is thus tightly linked to our understanding of the explosion mechanism of supernovae and supernova nucleosynthesis. X-ray and gamma-ray observations of young supernova remnants, combined with improved theoretical modeling, have resulted in enormous improvements in our knowledge of these events. The isotope ${}^{44}$Ti is one of the most sensitive probes of the innermost regions of the core collapse engine, and its spatial and velocity distribution are key observables. Hard X-ray imaging spectroscopy with the Nuclear Spectroscopic Telescope Array (NuSTAR) has provided new insights into the structure of the supernova remnant Cassiopeia A (Cas A), establishing the convective nature of the supernova engine. However, many questions about the details of this engine remain. We present here the concept for a balloon-borne follow-up mission called ASCENT (A SuperConducting ENergetic x-ray Telescope). ASCENT uses transition edge sensor gamma-ray microcalorimeter detectors with a demonstrated 55 eV Full Width Half Maximum (FWHM) energy resolution at 97 keV. This 8--16-fold improvement in energy resolution over NuSTAR will allow high resolution imaging and spectroscopy of the ${}^{44}$Ti emission. This will allow a detailed reconstruction of gamma-ray line redshifts, widths, and shapes, allowing us to address questions such as: What is the source of the neutron star "kicks"? What is the dominant production pathway for ${}^{44}$Ti? Is the engine of Cas A unique?

astro-ph.IM

Microstructure analysis of bismuth absorbers for transition-edge sensor X-ray microcalorimeters

Transition-edge sensors (TESs) as microcalorimeters offer high resolving power, owning to their sharp response and low operating temperature. In the hard X-ray regime and above, the demand for high quantum-efficiency requires the use of absorbers. Bismuth (Bi), owing to its low heat carrier density and high X-ray stopping power, has been widely used as an absorber material for TESs. However, distinct spectral responses have been observed for Bi absorbers deposited via evaporation versus electroplating. Evaporated Bi absorbers are widely observed to have a non-Gaussian tail on the low energy side of measured spectra. In this study, we fabricated Bi absorbers via these two methods, and performed microstructure analysis using scanning electron microscopy (SEM) and X-ray diffraction microscopy. The two types of material showed the same crystallographic structure, but the grain size of the evaporated Bi was about 40 times smaller than that of the electroplated Bi. This distinction in grain size is likely to be the cause of their different spectral responses.

physics.ins-det

Eliminating the non-Gaussian spectral response of X-ray absorbers for transition-edge sensors

Transition-edge sensors (TES) as microcalorimeters for high-energy-resolution X-ray spectroscopy are often fabricated with an absorber made of materials with high Z (for X-ray stopping power) and low heat capacity (for high resolving power). Bismuth represents one of the most compelling options. TESs with evaporated bismuth absorbers have shown spectra with undesirable and unexplained low-energy tails. We have developed TESs with electroplated bismuth absorbers over a gold layer that are not afflicted by this problem and that retain the other positive aspects of this material. To better understand these phenomena, we have studied a series of TESs with gold, gold/evaporated bismuth, and gold/electroplated bismuth absorbers, fabricated on the same die with identical thermal coupling. We show that bismuth morphology is linked to the spectral response of X-ray TES microcalorimeters.

physics.ins-det