Vendor-Agnostic Joint Relaxometry and Myelin Water Fraction Mapping with B1 and Motion Correction

Obtaining consistent quantitative maps of myelin content and relaxation times across different sites and vendors is essential for advancing our understanding of brain development. Herein, we present a harmonized, vendor-agnostic magnetic resonance acquisition method designed for joint T1, T2, and myelin water fraction mapping, along with a method for rapid B1+ and B1- field estimation. We used our dictionary-based fitting and multi-compartment modeling for joint mapping of T1, T2 and myelin water fraction. Self-navigation-based retrospective motion correction was integrated with subspace reconstruction to track and correct rigid head motion during scanning, operating without the need for external hardware. Simulations, phantom and in vivo experiments confirmed the sensitivity and accuracy of the method, particularly for short T2 values corresponding to myelin, and demonstrated consistent performance across multiple scanner types. Coupled with the harmonized calibration scan, the proposed package offers a practical tool for multi-site, multi-vendor neuroimaging studies in both adult and pediatric populations.

physics.med-ph↗

OpenMRF: A Modular, Vendor-Neutral Open-Source Framework for Reproducible Magnetic Resonance Fingerprinting using Pulseq

Purpose: Widespread adoption and methodological advancement of Magnetic Resonance Fingerprinting (MRF) are limited by the lack of unified, reproducible implementation frameworks and fragmented open-source tools. To address these barriers, we introduce OpenMRF - a comprehensive Pulseq-based solution - designed to enable consistent, reproducible, and transferable MRF research across vendors, sites, and field strengths. Methods: OpenMRF integrates modular Pulseq-based sequence design, Bloch-simulation-based dictionary creation directly from .seq files, and iterative low-rank subspace reconstruction. The framework was evaluated through digital phantom simulations, a multi-site ISMRM/NIST phantom study on Siemens MRI systems at 0.55 T, 1.5 T, and 3 T as well as GE and United Imaging 3 T platforms, and representative in vivo acquisitions in the liver (0.55 T), myocardium (1.5 T), and brain (3 T). Results: Simulations demonstrated high mapping accuracy in an ISMRM/NIST-like digital phantom, with low-rank reconstruction yielding deviations of 0.03+/-0.32 % (T1) and 0.12+/-1.94 % (T2). The multi-site phantom study yielded relaxation times consistent with reference values at all field strengths, with mean deviations of -0.1+/-2.9 % (T1), -1.5+/-8.7 % (T2), and -4.0+/-7.2 % (T1rho). In vivo acquisitions produced high-quality parameter maps across platforms and field strengths. Conclusion: OpenMRF provides a robust, open-source, end-to-end Pulseq-based solution for MRF that enables reproducible sequence implementation, physics-accurate dictionary simulation, and advanced reconstruction across vendors and field strengths. By providing a unified platform for method development, comparison, and multi-site validation, OpenMRF aims to accelerate reproducible and harmonized quantitative MRI research within the community.

physics.med-ph↗

Stochastic Optimization of 3D Non-Cartesian Sampling Trajectory (SNOPY)

Optimizing 3D k-space sampling trajectories for efficient MRI is important yet challenging. This work proposes a generalized framework for optimizing 3D non-Cartesian sampling patterns via data-driven optimization. We built a differentiable MRI system model to enable gradient-based methods for sampling trajectory optimization. By combining training losses, the algorithm can simultaneously optimize multiple properties of sampling patterns, including image quality, hardware constraints (maximum slew rate and gradient strength), reduced peripheral nerve stimulation (PNS), and parameter-weighted contrast. The proposed method can either optimize the gradient waveform (spline-based freeform optimization) or optimize properties of given sampling trajectories (such as the rotation angle of radial trajectories). Notably, the method optimizes sampling trajectories synergistically with either model-based or learning-based reconstruction methods. We proposed several strategies to alleviate the severe non-convexity and huge computation demand posed by the high-dimensional optimization. The corresponding code is organized as an open-source, easy-to-use toolbox. We applied the optimized trajectory to multiple applications including structural and functional imaging. In the simulation studies, the reconstruction PSNR of a 3D kooshball trajectory was increased by 4 dB with SNOPY optimization. In the prospective studies, by optimizing the rotation angles of a stack-of-stars (SOS) trajectory, SNOPY improved the PSNR by 1.4dB compared to the best empirical method. Optimizing the gradient waveform of a rotational EPI trajectory improved subjects' rating of the PNS effect from 'strong' to 'mild.' In short, SNOPY provides an efficient data-driven and optimization-based method to tailor non-Cartesian sampling trajectories.

eess.SP↗

Off-resonance artifact correction for magnetic resonance imaging: a review

In magnetic resonance imaging (MRI), inhomogeneity in the main magnetic field used for imaging, referred to as off-resonance, can lead to image artifacts ranging from mild to severe depending on the application. Off-resonance artifacts, such as signal loss, geometric distortions, and blurring, can compromise the clinical and scientific utility of MR images. In this review, we describe sources of off-resonance in MRI, how off-resonance affects images, and strategies to prevent and correct for off-resonance. Given recent advances and the great potential of low field and/or portable MRI, we also highlight the advantages and challenges of imaging at low field with respect to off-resonance.

eess.IV↗

B-spline Parameterized Joint Optimization of Reconstruction and K-space Trajectories (BJORK) for Accelerated 2D MRI

Optimizing k-space sampling trajectories is a promising yet challenging topic for fast magnetic resonance imaging (MRI). This work proposes to optimize a reconstruction method and sampling trajectories jointly concerning image reconstruction quality in a supervised learning manner. We parameterize trajectories with quadratic B-spline kernels to reduce the number of parameters and apply multi-scale optimization, which may help to avoid sub-optimal local minima. The algorithm includes an efficient non-Cartesian unrolled neural network-based reconstruction and an accurate approximation for backpropagation through the non-uniform fast Fourier transform (NUFFT) operator to accurately reconstruct and back-propagate multi-coil non-Cartesian data. Penalties on slew rate and gradient amplitude enforce hardware constraints. Sampling and reconstruction are trained jointly using large public datasets. To correct for possible eddy-current effects introduced by the curved trajectory, we use a pencil-beam trajectory mapping technique. In both simulations and in-vivo experiments, the learned trajectory demonstrates significantly improved image quality compared to previous model-based and learning-based trajectory optimization methods for 10 times acceleration factors. Though trained with neural network-based reconstruction, the proposed trajectory also leads to improved image quality with compressed sensing-based reconstruction.

eess.SP↗

Joint Design of RF and gradient waveforms via auto-differentiation for 3D tailored excitation in MRI

This paper proposes a new method for joint design of radiofrequency (RF) and gradient waveforms in Magnetic Resonance Imaging (MRI), and applies it to the design of 3D spatially tailored saturation and inversion pulses. The joint design of both waveforms is characterized by the ODE Bloch equations, to which there is no known direct solution. Existing approaches therefore typically rely on simplified problem formulations based on, e.g., the small-tip approximation or constraining the gradient waveforms to particular shapes, and often apply only to specific objective functions for a narrow set of design goals (e.g., ignoring hardware constraints). This paper develops and exploits an auto-differentiable Bloch simulator to directly compute Jacobians of the (Bloch-simulated) excitation pattern with respect to RF and gradient waveforms. This approach is compatible with \emph{arbitrary} sub-differentiable loss functions, and optimizes the RF and gradients directly without restricting the waveform shapes. For computational efficiency, we derive and implement explicit Bloch simulator Jacobians (approximately halving computation time and memory usage). To enforce hardware limits (peak RF, gradient, and slew rate), we use a change of variables that makes the 3D pulse design problem effectively unconstrained; we then optimize the resulting problem directly using the proposed auto-differentiation framework. We demonstrate our approach with two kinds of 3D excitation pulses that cannot be easily designed with conventional approaches: Outer-volume saturation (90° flip angle), and inner-volume inversion.

eess.IV↗

Fast, Precise Myelin Water Quantification using DESS MRI and Kernel Learning

Purpose: To investigate the feasibility of myelin water content quantification using fast dual-echo steady-state (DESS) scans and machine learning with kernels. Methods: We optimized combinations of steady-state (SS) scans for precisely estimating the fast-relaxing signal fraction ff of a two-compartment signal model, subject to a scan time constraint. We estimated ff from the optimized DESS acquisition using a recently developed method for rapid parameter estimation via regression with kernels (PERK). We compared DESS PERK ff estimates to conventional myelin water fraction (MWF) estimates from a longer multi-echo spin-echo (MESE) acquisition in simulation, in vivo, and ex vivo studies. Results: Simulations demonstrate that DESS PERK ff estimators and MESE MWF estimators achieve comparable error levels. In vivo and ex vivo experiments demonstrate that MESE MWF and DESS PERK ff estimates are quantitatively comparable measures of WM myelin water content. To our knowledge, these experiments are the first to demonstrate myelin water images from a SS acquisition that are quantitatively similar to conventional MESE MWF images. Conclusion: Combinations of fast DESS scans can be designed to enable precise ff estimation. PERK is well-suited for ff estimation. DESS PERK ff and MESE MWF estimates are quantitatively similar measures of WM myelin water content.

physics.med-ph↗

Dictionary-Free MRI PERK: Parameter Estimation via Regression with Kernels

This paper introduces a fast, general method for dictionary-free parameter estimation in quantitative magnetic resonance imaging (QMRI) via regression with kernels (PERK). PERK first uses prior distributions and the nonlinear MR signal model to simulate many parameter-measurement pairs. Inspired by machine learning, PERK then takes these parameter-measurement pairs as labeled training points and learns from them a nonlinear regression function using kernel functions and convex optimization. PERK admits a simple implementation as per-voxel nonlinear lifting of MRI measurements followed by linear minimum mean-squared error regression. We demonstrate PERK for $T_1,T_2$ estimation, a well-studied application where it is simple to compare PERK estimates against dictionary-based grid search estimates. Numerical simulations as well as single-slice phantom and in vivo experiments demonstrate that PERK and grid search produce comparable $T_1,T_2$ estimates in white and gray matter, but PERK is consistently at least $23\times$ faster. This acceleration factor will increase by several orders of magnitude for full-volume QMRI estimation problems involving more latent parameters per voxel.

stat.ML↗