SearcharxivSearch

arXiv subjects

Jonas Faltinath

Publications and source records attributed to Jonas Faltinath.

8 recordsLinked to original sources

The Tilting Mode: A New Degree of Freedom for Magneto-Mechanical Resonator Sensors

Magneto-mechanical resonators (MMRs) are an emerging class of passive, wireless sensors. Their torsional oscillation mode has recently been established for sensing and tracking applications. In this work, we report the identification and characterization of a second mechanical mode, the tilting mode, that provides sensitivity along an axis inaccessible to the torsional mode, opening up a new degree of freedom for tracking and sensing with a single MMR sensor. We derive an analytical model predicting the tilting frequency as a function of the geometric and magnetic parameters of the resonator, compare the tilting mode frequency to that of the torsional mode, and obtain a characteristic frequency ratio between the torsional and the tilting mode in the small angle approximation. Experimental characterization using three-axis excitation and detection confirms the mode's existence and its directional selectivity. Notably, the three-axis frequency response shows no observable cross-coupling between the torsional and the tilting mode. We further show that the tilting mode frequency follows the predicted dependence on magnet distance, confirming the analytical model and the mode's applicability for sensing, analogous to that of the torsional mode.

physics.app-ph

Parameter Estimation for Model-Based Sensing of Magneto-Mechanical Resonators

Magneto-mechanical resonators (MMRs) represent a recently proposed type of passive sensor that enables the estimation of its pose as well as sensing other parameters in its environment. The working principle of MMRs entails an excitation of the sensors by oscillating magnetic fields, followed by a readout process facilitated by inductive receiver coils. The sensing technology relies on real-time parameter estimation. This encompasses the solution of a nonlinear inverse problem, with the induced signals and a suitable forward model as inputs. The aim of this paper is twofold: first, to introduce a reference model and simplified models for the MMR dynamics and inductive readout, and second, to provide robust and real-time capable methods to estimate the model parameters. The effectiveness of the presented methods is evaluated in terms of their real-time potential, precision, and accuracy. All presented methods demonstrate the capacity to estimate the measured signal, with the simplified methods reducing the corresponding parameter estimation time by up to two orders of magnitude at the expense of less than 4 % deviation for large maximum deflection angles.

physics.app-ph

Simulating Gadolinium-Induced Magnetic Field Variations for Temperature Sensing with Magneto-Mechanical Resonators

Small-size magneto-mechanical resonators (MMR) represent an emerging class of passive, wireless sensors that combine a sensing functionality with a tracking option. The operation principle is based on a resonating rotor oscillation whose frequency is defined by the magnetic flux density of a stator magnet. One general sensing mechanism is the coupling of an external parameter to this resonator frequency. In this study, we investigate an approach for encoding a temperature information as a shift in the natural oscillation frequency utilizing the temperature-dependent magnetic properties of gadolinium (Gd). We perform an isolated simulation study on the temperature scaling of the magnetic field generation for stators coated with Gd of varying thickness. Our results show that the magnetic phase transition of Gd at its Curie temperature leads to a pronounced change in the magnetic permeability enabling a significant magnetic shielding behavior only for lower temperatures. In the transition regime, we find a peak sensitivity reaching 45.8 Hz/K exceeding existing values from the literature by up to a factor of $\sim$ 20. The findings of this work are an important step toward quantitative high-sensitivity temperature extraction with MMRs.

physics.app-ph

Uncertainties of a Spherical Magnetic Field Camera

Spherical harmonic expansions are well-established tools for estimating magnetic fields from surface measurements and are widely used in applications such as tomographic imaging, geomagnetism, and biomagnetism. Although the mathematical foundations of these expansions are well understood, the impact of real-world imperfections, on the uncertainty of the field model has received little attention. In this work, we present a systematic uncertainty propagation analysis for a magnetic field camera that estimates the field from surface measurements using a spherical array of Hall magnetometers arranged in a spherical t-design. A Monte Carlo-based approach is employed to quantify how sensor-related uncertainties, such as calibration errors and positioning inaccuracies, affect the spatial distribution of the estimated field's uncertainty. The results offer insights into the robustness of spherical harmonic methods and help identify the dominant sources of uncertainty in practical implementations.

physics.ins-det

Natural Frequency Dependency of Magneto-Mechanical Resonators on Magnet Distance

The precise derivation of physical quantities like temperature or pressure at arbitrary locations is useful in numerous contexts, e.g. medical procedures or industrial process engineering. The novel sensor technology of magneto-mechanical resonators (MMR), based on the interaction of a rotor and stator permanent magnet, allows for the combined tracking of the sensor position and orientation while simultaneously sensing an external measurand. Thereby, the quantity is coupled to the torsional oscillation frequency, e.g. by varying the magnet distance. In this paper, we analyze the (deflection angle-independent) natural frequency dependency of MMR sensors on the rotor-stator distance, and evaluate the performance of theoretical models. The three presented sensors incorporate magnets of spherical and/or cylindrical geometry and can be operated at adjustable frequencies within the range of 61.9-307.3 Hz. Our proposed method to obtain the natural frequency demonstrates notable robustness to variations in the initial deflection amplitudes and quality factors resulting in statistical errors on the mean smaller than 0.05 %. We find that the distance-frequency relationship is well described by an adapted dipole model accounting for material and manufacturing uncertainties. Their combined effect can be compensated by an adjustment of a single parameter which drives the median model deviation generally below 0.2 %. Our depicted methods and results are important for the design and calibration process of new sensor types utilizing the MMR technique.

physics.app-ph

Real-Time 3D Magnetic Field Camera for a Spherical Volume

Accurate and efficient volumetric magnetic field measurements are essential for a wide range of applications. Conventional methods are often limited in terms of measurement speed and applicability, or suffer from scaling problems at larger volumes. This work presents the development of a magnetometer array designed to measure magnetic fields within a spherical volume at a frame rate of 10 Hz. The array consists of 3D Hall magnetometers positioned according to a spherical $t$-design, allowing simultaneous magnetic field data acquisition from the surface of the sphere. The approach enables the efficient representation of all three components of the magnetic field inside the sphere using a sixth-degree polynomial, significantly reducing measurement time compared to sequential methods. This work details the design, calibration, and measurement methods of the array. To evaluate its performance, we compare it to a sequential single-sensor measurement by examining a magnetic gradient field. The obtained measurement uncertainties of approx. 1% show the applicability for a variety of applications.

physics.app-ph

Wireless and passive pressure detection using magneto-mechanical resonances in process engineering

A custom-developed magneto-mechanical resonator (MMR) for wireless pressure measurement is investigated for potential applications in process engineering. The MMR sensor utilises changes in the resonance frequency caused by pressure on a flexible 3D printed membrane. The thickness of the printed membrane plays a crucial role in determining the performance and sensitivity of MMRs, and can be tailored to meet the requirements of specific applications. The study includes static and dynamic measurements to determine the pressure sensitivity and temporal resolution of the sensor. The results show a minimum sensitivity of $0.06~\text{Hz mbar}^{-1}$ and are in agreement with theoretical calculations and measurements. The maximum sensor readout frequency is $2~\text{Hz}$ in this study. Additionally, the temperature dependence of the sensor is investigated, revealing a significant dependence of the resonance frequency on temperature. The developed MMR offers a promising and versatile method for precise pressure measurements in process engineering environments.

physics.app-ph

A cavity-microscope for micrometer-scale control of atom-photon interactions

Cavity quantum electrodynamics offers the possibility to observe and control the motion of few or individual atoms, enabling the realization of various quantum technological tasks such as quantum-enhanced metrology or quantum simulation of strongly-correlated matter. A core limitation of these experiments lies in the mode structure of the cavity field, which is hard-coded in the shape and geometry of the mirrors. As a result, most applications of cavity QED trade spatial resolution for enhanced sensitivity. Here, we propose and demonstrate a cavity-microscope device capable of controlling in space and time the coupling between atoms and light in a single-mode high-finesse cavity, reaching a spatial resolution an order-of-magnitude lower than the cavity mode waist. This is achieved through local Floquet engineering of the atomic level structure, imprinting a corresponding atom-field coupling. We illustrate this capability by engineering micrometer-scale coupling, using cavity-assisted atomic measurements and optimization. Our system forms an optical device with a single optical axis and has the same footprint and complexity as a standard Fabry-Perot cavity or confocal lens pair, and can be used for any atomic species. This technique opens a wide range of perspectives from ultra-fast, cavity-enhanced mid-circuit readout to the quantum simulation of fully connected models of quantum matter such as the Sachdev-Ye-Kitaev model.

cond-mat.quant-gas