Searcharxiv⌕ Search

arXiv subjects

Jonas Lynge Olesen

Publications and source records attributed to Jonas Lynge Olesen.

4 recordsLinked to original sources

Aries: A Proprietary Medium-Range Weather Prediction Model for the Energy Industry

Medium-range weather forecasting underpins operational and planning decisions across the energy industry. Developing competitive weather models was once the domain of national meteorological centers, but recent advances in machine-learned weather prediction (MLWP) have opened the field to industry. We present Aries, a SwinTransformer-based MLWP model developed at InCommodities. Aries is trained on ERA5 reanalysis data at 0.25\textdegree{} resolution, predicting 74 prognostic and 11 diagnostic atmospheric variables. We evaluate the model on 2025 ECMWF Analysis initializations, ensuring a recent and strictly out-of-sample test period for all models compared. On 10-metre wind speed, Aries outperforms both ECMWF HRES and AIFS in terms of RMSE for lead times up to four days, while on 2-metre temperature it achieves RMSE on par with AIFS operational. These results demonstrate that proprietary development of competitive weather models is technically viable, supporting a broader set of forecasts available for operational and planning applications in the energy industry.

physics.ao-ph↗

Evaluation of principal component analysis image denoising on multi-exponential MRI relaxometry

PURPOSE: Multi-exponential relaxometry is a powerful tool for characterizing tissue, but generally requires high image signal-to-noise ratio (SNR). This work evaluates the use of principal-component-analysis (PCA) denoising to mitigate these SNR demands and improve the precision of relaxometry measures. METHODS: PCA denoising was evaluated using both simulated and experimental MRI data. Bi-exponential transverse relaxation signals were simulated for a wide range of acquisition and sample parameters, and experimental data were acquired from three excised and fixed mouse brains. In both cases, standard relaxometry analysis was performed on both original and denoised image data, and resulting estimated signal parameters were compared. RESULTS: Denoising reduced the root-mean-square-error of parameters estimated from multi-exponential relaxometry by factors of 2 to 4x, for typical acquisition and sample parameters. Denoised images and subsequent parameter maps showed little or no signs of spatial artifact or loss of resolution. CONCLUSION: Experimental studies and simulations demonstrate that PCA denoising of MRI relaxometry data is an effective method of improving parameter precision without sacrificing image resolution. This simple yet important processing step thus paves the way for broader applicability of multi-exponential MRI relaxometry.

physics.med-ph↗

Diffusion time dependence of microstructural parameters in fixed spinal cord

Biophysical modelling of diffusion MRI is necessary to provide specific microstructural tissue properties. However, estimating model parameters from data with limited diffusion gradient strength, such as clinical scanners, has proven unreliable due to a shallow optimization landscape. On the other hand, estimation of diffusion kurtosis (DKI) parameters is more robust as the clinical acquisitions typically probe a regime in which the associated 4th order cumulant expansion is adequate; however, its parameters are not microstructurally specific a priori. Given an appropriate biophysical model, its parameters may be connected to DKI parameters, but it was previously shown that at the DKI level, it still does not provide sufficient information to uniquely determine all model parameters. Earlier work has shown that by neglecting axonal dispersion, this parameter degeneracy reduces to the question of whether intra-axonal diffusivity is larger than or smaller than extra-axonal diffusivity. Here we develop a model of diffusion in spinal cord white matter including axonal dispersion and demonstrate stable estimation of all model parameters from DKI. By employing the recently developed fast axisymmetric DKI, we use stimulated echo acquisition mode to collect data over an unprecedented diffusion time range with very narrow diffusion gradient pulses, enabling finely resolved measurements of diffusion time dependence of both net diffusion and kurtosis metrics, as well as model intra- and extra-axonal diffusivities, and axonal dispersion. Our results demonstrate substantial time dependence of all parameters except volume fractions, and the additional time dimension provides support for intra-axonal diffusivity to be larger than extra-axonal diffusivity in spinal cord white matter, although not unambiguously. We compare our findings to predictions from effective medium theory.

physics.med-ph↗

Effects of nongaussian diffusion on "isotropic diffusion measurements'': an ex-vivo microimaging and simulation study

Designing novel diffusion-weighted pulse sequences to probe tissue microstructure beyond the conventional Stejskal-Tanner family is currently of broad interest. One such technique, multidimensional diffusion MRI, has been recently proposed to afford model-free decomposition of diffusion signal kurtosis into terms originating from either ensemble variance of isotropic diffusivity or microscopic diffusion anisotropy. This ability rests on the assumption that diffusion can be described as a sum of multiple Gaussian compartments, but this is often not strictly fulfilled. The effects of nongaussian diffusion on single shot isotropic diffusion sequences were first considered in detail by de Swiet and Mitra in 1996. They showed theoretically that anisotropic compartments lead to anisotropic time dependence of the diffusion tensors, which causes the measured isotropic diffusivity to depend on gradient frame orientation. Here we show how such deviations from the multiple Gaussian compartments assumption conflates orientation dispersion with ensemble variance in isotropic diffusivity. Second, we consider additional contributions to the apparent variance in isotropic diffusivity arising due to intracompartmental kurtosis. These will likewise depend on gradient frame orientation. We illustrate the potential importance of these confounds with analytical expressions, numerical simulations in simple model geometries, and microimaging experiments in fixed spinal cord using isotropic diffusion encoding waveforms with 7.5 ms duration and 3000 mT/m maximum amplitude.

physics.bio-ph↗