Searcharxiv⌕ Search

arXiv subjects

Jonas Zmuidzinas

Publications and source records attributed to Jonas Zmuidzinas.

At least 37 records · Page 2Linked to original sources

SuperSpec: design concept and circuit simulations

SuperSpec is a pathfinder for future lithographic spectrometer cameras, which promise to energize extra-galactic astrophysics at (sub)millimeter wavelengths: delivering 200--500 km/s spectral velocity resolution over an octave bandwidth for every pixel in a telescope's field of view. We present circuit simulations that prove the concept, which enables complete millimeter-band spectrometer devices in just a few square-millimeter footprint. We evaluate both single-stage and two-stage channelizing filter designs, which separate channels into an array of broad-band detectors, such as bolometers or kinetic inductance detector (KID) devices. We discuss to what degree losses (by radiation or by absorption in the dielectric) and fabrication tolerances affect the resolution or performance of such devices, and what steps we can take to mitigate the degradation. Such design studies help us formulate critical requirements on the materials and fabrication process, and help understand what practical limits currently exist to the capabilities these devices can deliver today or over the next few years.

astro-ph.IM↗

Status of MUSIC, the MUltiwavelength Sub/millimeter Inductance Camera

We present the status of MUSIC, the MUltiwavelength Sub/millimeter Inductance Camera, a new instrument for the Caltech Submillimeter Observatory. MUSIC is designed to have a 14', diffraction-limited field-of-view instrumented with 2304 detectors in 576 spatial pixels and four spectral bands at 0.87, 1.04, 1.33, and 1.98 mm. MUSIC will be used to study dusty star-forming galaxies, galaxy clusters via the Sunyaev-Zeldovich effect, and star formation in our own and nearby galaxies. MUSIC uses broadband superconducting phased-array slot-dipole antennas to form beams, lumped-element on-chip bandpass filters to define spectral bands, and microwave kinetic inductance detectors to senseincoming light. The focal plane is fabricated in 8 tiles consisting of 72 spatial pixels each. It is coupled to the telescope via an ambient temperature ellipsoidal mirror and a cold reimaging lens. A cold Lyot stop sits at the image of the primary mirror formed by the ellipsoidal mirror. Dielectric and metal mesh filters are used to block thermal infrared and out-of-band radiation. The instrument uses a pulse tube cooler and 3He/3He/4He closed-cycle cooler to cool the focal plane to below 250 mK. A multilayer shield attenuates Earth's magnetic field. Each focal plane tile is read out by a single pair of coaxes and a HEMT amplifier. The readout system consists of 16 copies of custom-designed ADC/DAC and IF boards coupled to the CASPER ROACH platform. We focus on recent updates on the instrument design and results from the commissioning of the full camera in 2012.

astro-ph.IM↗

MAKO: a pathfinder instrument for on-sky demonstration of low-cost 350 micron imaging arrays

Submillimeter cameras now have up to $10^4$ pixels (SCUBA 2). The proposed CCAT 25-meter submillimeter telescope will feature a 1 degree field-of-view. Populating the focal plane at 350 microns would require more than $10^6$ photon-noise limited pixels. To ultimately achieve this scaling, simple detectors and high-density multiplexing are essential. We are addressing this long-term challenge through the development of frequency-multiplexed superconducting microresonator detector arrays. These arrays use lumped-element, direct-absorption resonators patterned from titanium nitride films. We will discuss our progress toward constructing a scalable 350 micron pathfinder instrument focusing on fabrication simplicity, multiplexing density, and ultimately a low per-pixel cost.

astro-ph.IM↗

Crosstalk Reduction for Superconducting Microwave Resonator Arrays

Large-scale arrays of Microwave Kinetic Inductance Detectors (MKIDs) are attractive candidates for use in imaging instruments for next generation submillimeter-wave telescopes such as CCAT. We have designed and fabricated tightly packed ~250-pixel MKID arrays using lumped-element resonators etched from a thin layer of superconducting TiNx deposited on a silicon substrate. The high pixel packing density in our initial design resulted in large microwave crosstalk due to electromagnetic coupling between the resonators. Our second design eliminates this problem by adding a grounding shield and using a double-wound geometry for the meander inductor to allow conductors with opposite polarity to be in close proximity. In addition, the resonator frequencies are distributed in a checkerboard pattern across the array. We present details for the two resonator and array designs and describe a circuit model for the full array that predicts the distribution of resonator frequencies and the crosstalk level. We also show results from a new experimental technique that conveniently measures crosstalk without the need for an optical setup. Our results reveal an improvement in crosstalk from 57% in the initial design down to \leq 2% in the second design. The general procedure and design guidelines in this work are applicable to future large arrays employing microwave resonators.

physics.ins-det↗

A Wideband, Low-Noise Superconducting Amplifier with High Dynamic Range

Amplifiers are ubiquitous in electronics and play a fundamental role in a wide range of scientific measurements. From a user's perspective, an ideal amplifier has very low noise, operates over a broad frequency range, and has a high dynamic range - it is capable of handling strong signals with little distortion. Unfortunately, it is difficult to obtain all of these characteristics simultaneously. For example, modern transistor amplifiers offer multi-octave bandwidths and excellent dynamic range. However, their noise remains far above the fundamental limit set by the uncertainty principle of quantum mechanics. Parametric amplifiers, which predate transistor amplifiers and are widely used in optics, exploit a nonlinear response to transfer power from a strong pump tone to a weak signal. If the nonlinearity is purely reactive, ie. nondissipative, in theory the amplifier noise can reach the quantum-mechanical limit. Indeed, microwave frequency superconducting Josephson parametric amplifiers do approach the quantum limit, but generally are narrow band and have very limited dynamic range. In this paper, we describe a superconducting parametric amplifier that overcomes these limitations. The amplifier is very simple, consisting only of a patterned metal film on a dielectric substrate, and relies on the nonlinear kinetic inductance of a superconducting transmission line. We measure gain extending over 2 GHz on either side of an 11.56 GHz pump tone, and we place an upper limit on the added noise of the amplifier of 3.4 photons at 9.4 GHz. Furthermore, the dynamic range is very large, comparable to microwave transistor amplifiers, and the concept can be applied throughout the microwave, millimeter-wave and submillimeter-wave bands.

cond-mat.supr-con↗

Titanium Nitride Films for Ultrasensitive Microresonator Detectors

Titanium nitride (TiNx) films are ideal for use in superconducting microresonator detectors because: a) the critical temperature varies with composition (0 < Tc < 5 K); b) the normal-state resistivity is large, ρ_n ~ 100 $μ$Ohm cm, facilitating efficient photon absorption and providing a large kinetic inductance and detector responsivity; and c) TiN films are very hard and mechanically robust. Resonators using reactively sputtered TiN films show remarkably low loss (Q_i > 10^7) and have noise properties similar to resonators made using other materials, while the quasiparticle lifetimes are reasonably long, 10-200 $μ$s. TiN microresonators should therefore reach sensitivities well below 10^-19 WHz^(-1/2).

cond-mat.supr-con↗

ARCONS: A highly multiplexed superconducting optical to near-IR camera

We report on the development of ARCONS, the ARray Camera for Optical to Near-IR Spectrophotometry. This photon counting integral field unit (IFU), being built at UCSB and Caltech with detectors fabricated at JPL, will use a unique, highly multiplexed low temperature detector technology known as Microwave Kinetic Inductance Detectors (MKIDs). These detectors, which operate at 100 mK, should provide photon counting with energy resolution of R = E/δE > 20 and time resolution of a microsecond, with a quantum efficiency of around 50%. We expect to field the instrument at the Palomar 200" telescope in the first quarter of 2011 with an array containing 1024 pixels in a 32x32 pixel form factor to yield a field of view of approximately 10x10 arcseconds. The bandwidth of the camera is limited by the rising sky count rate at longer wavelengths, but we anticipate a bandwidth of 0.35 to 1.35 μm will be achievable. A simple optical path and compact dewar utilizing a cryogen-free adiabatic demagnetization refridgerator (ADR) allows the camera to be deployed quickly at Naysmith or Coude foci at a variety of telescopes. A highly expandable software defined radio (SDR) readout that can scale up to much larger arrays has been developed.

astro-ph.IM↗

Interstellar OH+, H2O+ and H3O+ along the sight-line to G10.6-0.4

We report the detection of absorption lines by the reactive ions OH+, H2O+ and H3O+ along the line of sight to the submillimeter continuum source G10.6$-$0.4 (W31C). We used the Herschel HIFI instrument in dual beam switch mode to observe the ground state rotational transitions of OH+ at 971 GHz, H2O+ at 1115 and 607 GHz, and H3O+ at 984 GHz. The resultant spectra show deep absorption over a broad velocity range that originates in the interstellar matter along the line of sight to G10.6$-$0.4 as well as in the molecular gas directly associated with that source. The OH+ spectrum reaches saturation over most velocities corresponding to the foreground gas, while the opacity of the H2O+ lines remains lower than 1 in the same velocity range, and the H3O+ line shows only weak absorption. For LSR velocities between 7 and 50 kms$^{-1}$ we estimate total column densities of $N$(OH+) $> 2.5 \times 10^{14}$ cm$^{-2}$, $N$(H2O+) $\sim 6 \times 10^{13}$ cm$^{-2}$ and $N$(H3O+) $\sim 4.0 \times 10^{13}$ cm$^{-2}$. These detections confirm the role of O$^+$ and OH$^+$ in initiating the oxygen chemistry in diffuse molecular gas and strengthen our understanding of the gas phase production of water. The high ratio of the OH+ by the H2O+ column density implies that these species predominantly trace low-density gas with a small fraction of hydrogen in molecular form.

astro-ph.GA↗

Two-level system noise reduction for Microwave Kinetic Inductance Detectors

Noise performance is one of the most crucial aspects of any detector. Superconducting Microwave Kinetic Inductance Detectors (MKIDs) have an "excess" frequency noise that shows up as a small time dependent jitter of the resonance frequency characterized by the frequency noise power spectrum measured in units of Hz^2/Hz. Recent studies have shown that this noise almost certainly originates from a surface layer of two-level system (TLS) defects on the metallization or substrate. Fluctuation of these TLSs introduces noise in the resonator due to coupling of the TLS electric dipole moments to the resonator's electric field. Motivated by a semi-empirical quantitative theory of this noise mechanism, we have designed and tested new resonator geometries in which the high-field "capacitive" portion of the CPW resonator is replaced by an interdigitated capacitor (IDC) structure with 10 - 20 micron electrode spacing, as compared to the 2 micron spacing used for our more conventional CPW resonators. Measurements show that this new IDC design has dramatically lower TLS noise, currently by about a factor of ~29 in terms of the frequency noise power spectrum, corresponding to an improvement of about a factor of 29^(1/2) in NEP. These new devices are replacing the CPW resonators in our next design iteration in progress for MKIDCam. Opportunities and prospects for future reduction of the TLS noise will be discussed.

physics.ins-det↗

Study of the Experimental Probe of Inflationary Cosmology (EPIC)-Intemediate Mission for NASA's Einstein Inflation Probe

Measurements of Cosmic Microwave Background (CMB) anisotropy have served as the best experimental probe of the early universe to date. The inflationary paradigm, inspired in part by the extreme isotropy of the CMB, is now a cornerstone in modern cosmology. Inflation has passed a series of rigorous experimental tests, but we still do not understand the physical mechanism or energy scale behind inflation. A general prediction of inflation and one that can provide certain insights into inflationary physics is a background of primordial gravitational waves. These perturbations leave a distinct signature in the CMB B-modes of polarization. The EPIC (Experimental Probe of Inflationary Cosmology) study team has investigated several CMB polarization mission concepts to carry out a definitive measurement of the inflationary B-mode polarization spectrum. In this report we study a mission with an aperture intermediate between the two missions discussed in our previous report. EPIC-IM's increased aperture allows access to a broader science case than the small EPIC-Low Cost mission. In addition to the search for inflationary gravitational waves, the increase aperture allows us to mine the scale polarization and lensing shear polarization signals down to cosmological limits, so that we extract virtually all the cosmological information available from the CMB. In addition, a modest number of channels operating at higher frequencies allows for an all-sky measurement of polarized Galactic dust, which will provide a rich dataset for Galactic science related to magnetic fields. Using a combination of a large sensitivity focal plane with a new optical design, and an efficient 4K mechanical cooler, EPIC-IM realizes higher sensitivity than EPIC-Comprehensive Science mission.

astro-ph.CO↗

Training of Instrumentalists and Development of New Technologies on SOFIA

This white paper is submitted to the Astronomy and Astrophysics 2010 Decadal Survey (Astro2010)1 Committee on the State of the Profession to emphasize the potential of the Stratospheric Observatory for Infrared Astronomy (SOFIA) to contribute to the training of instrumentalists and observers, and to related technology developments. This potential goes beyond the primary mission of SOFIA, which is to carry out unique, high priority astronomical research. SOFIA is a Boeing 747SP aircraft with a 2.5 meter telescope. It will enable astronomical observations anywhere, any time, and at most wavelengths between 0.3 microns and 1.6 mm not accessible from ground-based observatories. These attributes, accruing from the mobility and flight altitude of SOFIA, guarantee a wealth of scientific return. Its instrument teams (nine in the first generation) and guest investigators will do suborbital astronomy in a shirt-sleeve environment. The project will invest $10M per year in science instrument development over a lifetime of 20 years. This, frequent flight opportunities, and operation that enables rapid changes of science instruments and hands-on in-flight access to the instruments, assure a unique and extensive potential - both for training young instrumentalists and for encouraging and deploying nascent technologies. Novel instruments covering optical, infrared, and submillimeter bands can be developed for and tested on SOFIA by their developers (including apprentices) for their own observations and for those of guest observers, to validate technologies and maximize observational effectiveness.

astro-ph.IM↗

A complete view of galaxy evolution: panchromatic luminosity functions and the generation of metals

When and how did galaxies form and their metals accumulate? Over the last decade, this has moved from an archeological question to a live investigation: there is now a broad picture of the evolution of galaxies in dark matter halos: their masses, stars, metals and supermassive blackholes. Galaxies have been found and studied in which these formation processes are taking place most vigorously, all the way back in cosmic time to when the intergalactic medium (IGM) was still largely neutral. However, the details of how and why the interstellar medium (ISM) in distant galaxies cools, is processed, recycled and enriched in metals by stars, and fuels active galactic nuclei (AGNs) remain uncertain. In particular, the cooling of gas to fuel star formation, and the chemistry and physics of the most intensely active regions is hidden from view at optical wavelengths, but can be seen and diagnosed at mid- & far-infrared (IR) wavelengths. Rest-frame IR observations are important first to identify the most luminous, interesting and important galaxies, secondly to quantify accurately their total luminosity, and finally to use spectroscopy to trace the conditions in the molecular and atomic gas out of which stars form. In order to map out these processes over the full range of environments and large-scale structures found in the universe - from the densest clusters of galaxies to the emptiest voids - we require tools for deep, large area surveys, of millions of galaxies out to z~5, and for detailed follow-up spectroscopy. The necessary tools can be realized technically. Here, we outline the requirements for gathering the crucial information to build, validate and challenge models of galaxy evolution.

astro-ph.CO↗

A semi-empirical model for two-level system noise in superconducting microresonators

We present measurements of the low--temperature excess frequency noise of four niobium superconducting coplanar waveguide microresonators, with center strip widths $s_r$ ranging from 3 $μ$m to 20 $μ$m. For a fixed internal power, we find that the frequency noise decreases rapidly with increasing center strip width, scaling as $1/s_r^{1.6}$. We show that this geometrical scaling is readily explained by a simple semi-empirical model which assumes a surface distribution of independent two-level system fluctuators. These results allow the resonator geometry to be optimized for minimum noise.

cond-mat.supr-con↗

Experimental evidence for a surface distribution of two-level systems in superconducting lithographed microwave resonators

We present measurements of the temperature-dependent frequency shift of five niobium superconducting coplanar waveguide microresonators with center strip widths ranging from 3 $μ$m to 50 $μ$m, taken at temperatures in the range 100-800 mK, far below the 9.2 K transition temperature of niobium. These data agree well with the two-level system (TLS) theory. Fits to this theory provide information on the number of TLS that interact with each resonator geometry. The geometrical scaling indicates a surface distribution of TLS, and the data are consistent with a TLS surface layer thickness of order a few nm, as might be expected for a native oxide layer.

cond-mat.supr-con↗

Temperature Dependence of the Frequency and Noise of Superconducting Coplanar Waveguide Resonators

We present measurements of the temperature and power dependence of the resonance frequency and frequency noise of superconducting niobium thin-film coplanar waveguide resonators, carried out at temperatures well below the superconducting transition (T_{c}=9.2 K). The noise decreases by nearly two orders of magnitude as the temperature is increased from 120 to 1200 mK, while the variation of the resonance frequency with temperature over this range agrees well with the standard two-level system (TLS) model for amorphous dielectrics. These results support the hypothesis that TLS are responsible for the noise in superconducting microresonators, and have important implications for resonator applications such as qubits and photon detectors.

cond-mat.supr-con↗

The Cornell Caltech Atacama Telescope

Cornell University, the California Institute for Technology, and the Jet Propulsion Laboratory are jointly studying the construction of a 25 m diameter telescope for submillimeter astronomy on a high mountain in northern Chile. This Cornell Caltech Atacama Telescope (CCAT) will combine high sensitivity, a wide field of view, and a broad wavelength range to provide an unprecedented capability for deep, large area, multi-color submillimeter surveys to complement narrow field, high resolution studies with ALMA. CCAT observations will address fundamental themes in contemporary astronomy, notably the formation and evolution of galaxies, the nature of the dark matter and dark energy that comprise most of the content of the universe, the formation of stars and planets, the conditions in circumstellar disks, and the conditions during the early history of the Solar system. The candidate CCAT site, at 5600 m in northern Chile, enjoys superb observing conditions. To accommodate large format bolometer cameras, CCAT is designed with a 20 arcmin field of view. CCAT will incorporate closed loop active control of its segmented primary mirror to maintain a half wavefront error of 10 mum rms or less. Instrumentation under consideration includes both short (650 mum-200 mum) and long (2 mm-750 mum) wavelength bolometer cameras, direct detection spectrometers, and heterodyne receiver arrays. The University of Colorado, a Canadian university consortium, and the UK Astronomy Technology Centre on behalf of the UK community are pursuing participation in the CCAT consortium. When complete early in the next decade, CCAT will be the largest and most sensitive facility of its class as well as the highest altitude astronomical facility on Earth.

astro-ph↗

Noise Properties of Superconducting Coplanar Waveguide Microwave Resonators

We have measured noise in thin-film superconducting coplanar waveguide resonators. This noise appears entirely as phase noise, equivalent to a jitter of the resonance frequency. In contrast, amplitude fluctuations are not observed at the sensitivity of our measurement. The ratio between the noise power in the phase and amplitude directions is large, in excess of 30 dB. These results have important implications for resonant readouts of various devices such as detectors, amplifiers, and qubits. We suggest that the phase noise is due to two-level systems in dielectric materials.

cond-mat.supr-con↗

Cornell Caltech Atacama Telescope (CCAT): a 25 m aperture telescope above 5000 m altitude

Cornell, California Institute of Technology (Caltech), and Jet Propulsion Lab (JPL) have joined together to study development of a 25 meter sub-millimeter telescope (CCAT) on a high peak in the Atacama region of northern Chile, where the atmosphere is so dry as to permit observation at wavelengths as short as 200 micron. The telescope is designed to deliver high efficiency images at that wavelength with a total 1/2 wavefront error of about 10 microns. With a 20 arc min field of view, CCAT will be able to accommodate large format bolometer arrays and will excel at carrying out surveys as well as resolving structures to the 2 arc sec. resolution level. The telescope will be an ideal complement to ALMA. Initial instrumentation will include both a wide field bolometer camera and a medium resolution spectrograph. Studies of the major telescope subsystems have been performed as part of an initial Feasibility Concept Study. Novel aspects of the telescope design include kinematic mounting and active positioning of primary mirror segments, high bandwidth secondary mirror segment motion control for chopping, a Calotte style dome of 50 meter diameter, a mount capable of efficient scanning modes of operation, and some new approaches to panel manufacture. Analysis of telescope performance and of key subsystems will be presented to illustrate the technical feasibility and pragmatic cost of CCAT. Project plans include an Engineering Concept Design phase followed by detailed design and development. First Light is planned for early 2012.

astro-ph↗