Microrheology with Optical Tweezers: Measuring the solutions' relative viscosity at a glance

We present a straightforward method for measuring the fluids' relative viscosity via a simple graphical analysis of the normalised position autocorrelation function of an optically trapped bead, without the need of embarking on laborious calculations. The advantages of the proposed microrheology method become evident, for instance, when it is adopted for measuring the molecular weight of rare or precious materials by means of their intrinsic viscosity. The proposed method has been validated by direct comparison with conventional bulk rheology methods.

physics.flu-dyn

Partial synchronisation of stochastic oscillators through hydrodynamic coupling

Holographic optical tweezers are used to construct a static bistable optical potential energy landscape where a Brownian particle experiences restoring forces from two nearby optical traps and undergoes thermally activated transitions between the two energy minima. Hydrodynamic coupling between two such systems results in their partial synchronisation. This is interpreted as an emergence of higher mobility pathways, along which it is easier to overcome barriers to structural rearrangement.

cond-mat.mes-hall

Measuring the viscous and elastic properties of single cells using video particle tracking microrheology

We present a simple and \emph{non-invasive} experimental procedure to measure the linear viscoelastic properties of cells by passive video particle tracking microrheology. In order to do this, a generalised Langevin equation is adopted to relate the time-dependent thermal fluctuations of a bead, chemically bound to the cell's \emph{exterior}, to the frequency-dependent viscoelastic moduli of the cell. It is shown that these moduli are related to the cell's cytoskeletal structure, which in this work is changed by varying the solution osmolarity from iso- to hypo-osmotic conditions. At high frequencies, the viscoelastic moduli frequency dependence changes from $\propto ω^{3/4}$ found in iso-osmotic solutions to $\propto ω^{1/2}$ in hypo--osmotic solutions; the first situation is typical of bending modes in isotropic \textit{in vitro} reconstituted F--actin networks, and the second could indicate that the restructured cytoskeleton behaves as a gel with "\textit{dangling branches}". The insights gained from this form of rheological analysis could prove to be a valuable addition to studies that address cellular physiology and pathology.

physics.bio-ph

Optical tweezers: wideband microrheology

Microrheology is a branch of rheology having the same principles as conventional bulk rheology, but working on micron length scales and micro-litre volumes. Optical tweezers have been successfully used with Newtonian fluids for rheological purposes such as determining fluid viscosity. Conversely, when optical tweezers are used to measure the viscoelastic properties of complex fluids the results are either limited to the material's high-frequency response, discarding important information related to the low-frequency behavior, or they are supplemented by low-frequency measurements performed with different techniques, often without presenting an overlapping region of clear agreement between the sets of results. We present a simple experimental procedure to perform microrheological measurements over the widest frequency range possible with optical tweezers. A generalised Langevin equation is used to relate the frequency-dependent moduli of the complex fluid to the time-dependent trajectory of a probe particle as it flips between two optical traps that alternately switch on and off.

physics.optics

Measuring storage and loss moduli using optical tweezers: broadband microrheology

We present an experimental procedure to perform broadband microrheological measurements with optical tweezers. A generalised Langevin equation is adopted to relate the time-dependent trajectory of a particle in an imposed flow to the frequency-dependent moduli of the complex fluid. This procedure allows us to measure the material linear viscoelastic properties across the widest frequency range achievable with optical tweezers.