Analytical and Cross-Sectional Clinical Validity of a Smartphone-Based U-Turn Test in Multiple Sclerosis

Background: Gait and balance impairment can profoundly impact people with multiple sclerosis (PwMS). Objectives: To evaluate the analytical and clinical validity of the U-Turn Test (UTT), a smartphone-based assessment of dynamic balance in PwMS. Methods: The GaitLab study (ISRCTN15993728) enrolled adult PwMS (EDSS 0.0-6.5). PwMS performed the UTT in a gait laboratory (supervised) using 6 smartphones at different wear locations and daily during a two-week remote period (unsupervised) using one smartphone (belt front). Median turn speed was computed per UTT. In the supervised setting, turn detection accuracy of smartphones was compared to motion capture (mocap) via F1 scores. Agreement between smartphone- and mocap-derived turn speed was assessed by Bland-Altman and ICC(3,1). In the unsupervised setting, test-retest reliability (ICC[2,1]) and correlations with Timed 25-Foot Walk (T25FW), EDSS, Ambulation Score, 12-item Multiple Sclerosis Walking Scale (MSWS-12), and Activities-specific Balance Confidence scale (ABC) were evaluated. Results: Ninety-six PwMS were included. Turn speed was comparable across supervised (1.44 rad/s) and unsupervised settings (1.47 rad/s). In the supervised setting, turn detection was highly accurate (F1 >95% across wear locations). Turn speed agreement with mocap was high (ICC[3,1]: 0.87-0.92), with minimal bias (-0.04 to 0.11 rad/s). Unsupervised test-retest reliability (ICC[2,1]) was >0.90 when aggregating >=2 tests. Turn speed correlated with T25FW (rho=-0.79), EDSS (rho=-0.75), Ambulation score (rho=-0.73), MSWS-12 (rho=-0.65), and ABC (rho=-0.61). Conclusion: The UTT accurately and reproducibly measures turn speed across wear locations and settings, providing complementary dynamic balance insights to clinical measures and showing potential for use in multiple sclerosis trials.

eess.SP

Adaptive and robust smartphone-based step detection in multiple sclerosis

Background: Many attempts to validate gait pipelines that process sensor data to detect gait events have focused on the detection of initial contacts only in supervised settings using a single sensor. Objective: To evaluate the performance of a gait pipeline in detecting initial/final contacts using a step detection algorithm adaptive to different test settings, smartphone wear locations, and gait impairment levels. Methods: In GaitLab (ISRCTN15993728), healthy controls (HC) and people with multiple sclerosis (PwMS; Expanded Disability Status Scale 0.0-6.5) performed supervised Two-Minute Walk Test [2MWT] (structured in-lab overground and treadmill 2MWT) during two on-site visits carrying six smartphones and unsupervised walking activities (structured and unstructured real-world walking) daily for 10-14 days using a single smartphone. Reference gait data were collected with a motion capture system or Gait Up sensors. The pipeline's performance in detecting initial/final contacts was evaluated through F1 scores and absolute temporal error with respect to reference measurement systems. Results: We studied 35 HC and 93 PwMS. Initial/final contacts were accurately detected across all smartphone wear locations. Median F1 scores for initial/final contacts on in-lab 2MWT were >=99.0%/>=97.6% in HC and >=99.0%/98.2% in PwMS. F1 scores remained high on structured (HC: 100%/100%; PwMS: 99.9%/99.5%) and unstructured real-world walking (HC: 97.8%/97.8%; PwMS: 94.4%/94.0%). Median temporal errors were <=0.08 s. Neither age, sex, disease severity, walking aid use, nor setting (outdoor/indoor) impacted pipeline performance (all p>0.05). Conclusion: This gait pipeline accurately and consistently detects initial and final contacts in PwMS across different smartphone locations and environments, highlighting its potential for real-world gait assessment.

eess.SP

Annotation and synchronization of smartphone inertial measurement unit and motion capture data collected in a laboratory setting to study gait and balance

Validating smartphone sensor-based tests to study gait and balance against reference measurement systems in a laboratory setting poses several technical challenges related to data quality and data processing. One challenge is to guarantee the correct annotation of the data, which is required to ensure that only data collected during the same test execution are compared across measurement systems in subsequent analyses. A second challenge is to accurately synchronize the data across the different systems. Here, we propose innovative solutions for both challenges and illustrate their use in the example of comparing smartphone sensor data collected with the Floodlight technology with data collected with a motion capture system. These solutions form important tools for guaranteeing the data quality and data integrity required for the validation of gait and balance characteristics measured by digital health technology tools such as the Floodlight technology.