Searcharxiv⌕ Search

arXiv subjects

Joong Hyun Kim

Publications and source records attributed to Joong Hyun Kim.

2 recordsLinked to original sources

Neutron spectrum measurement in the Yemi underground laboratory

We report on the measurement of neutron energy spectra at the newly established Yemi Underground Laboratory (Yemilab) in the Republic of Korea, designed to host dark matter and rare-event search experiments. A high-sensitivity neutron spectrometer was employed, consisting of ten cylindrical {}^{3}He proportional counters, eight of which were embedded in cylindrical high-density polyethylene moderators of various sizes. To quantify and mitigate contributions from internal α-backgrounds, each detector underwent a dedicated background measurement using a cadmium-shielded box. These backgrounds, primarily originating from trace amounts of U and Th in the stainless-steel housings, were characterized and subtracted during data analysis. Neutron measurements were carried out at three locations within the Yemilab between March to October 2023. After waveform-based event selection and correction for \alphasym-backgrounds, neutron count rates were estimated and corresponding energy spectra were reconstructed using the unfolding method. The total neutron fluence rates were measured ranged from (3.24 $\pm$ 0.11) to (4.01 $\pm$ 0.10) $\times~10^{-5}~ {cm}^{-2}~{s}^{-1}$, with thermal and fast neutron components (1 - 10 MeV) ranging from (1.32 $\pm$ 0.05) to (1.51 $\pm$ 0.05) $\times 10^{-5}~{cm}^{-2}~{s}^{-1}$ and (0.27 $\pm$ 0.03) to (0.34 $\pm$ 0.10) $\times~10^{-5}~{cm}^{-2}~{s}^{-1}$, respectively.

physics.ins-det↗

Design Optimization of a Small-animal SPECT System Using LGSO Continuous Crystal and a Micro Parallel-hole Collimator

The aim of this study was to optimize the design of a monolithic LGSO scintillation crystal and micro parallel-hole collimator for the development of a small-animal single photon emission computed tomography (SPECT) system with compact size, low-cost and reasonable performance through Monte Carlo simulation. L0.9GSO crystals with surface area of 50 mm X 50 mm were investigated for the design optimization. The intrinsic detection efficiency, intrinsic spatial resolution, and intrinsic energy resolution of crystals were estimated for different crystal thicknesses and photon energies (using I-125 and Tc-99m sources). Two kinds of surface treatments (providing polished and rough surfaces) were compared by optical photon simulation. The standard deviation of the angle between a micro-facet and the mean surface was set to 0.1 and 6.0 for polished and rough surfaces, respectively. For comparison, the intrinsic performance of NaI(Tl) was also investigated. A multi-photomultiplier tube was designed with 16 X 16 anode pixels having size of 2.8 mm X 2.8 mm and pitch of 3.04 mm, and a 1.5 mm thickness glass window. The length of the micro collimator was also optimized. Finally, the performance of the SPECT system was assessed and an ultra-micro hot spot phantom image was obtained in simulation. The 1-mm-thick LGSO was sufficient to detect most incident photons from I-125 but a thickness of 3 mm was required for Tc-99m imaging. Polished crystal yielded better intrinsic spatial resolution (~540 μm) and lower light output than rough crystal. Energy resolutions of I-125 and Tc-99m were ~36.9% and ~19.1%. With the optimized collimator length, spatial resolution of ~1 mm and sensitivity of ~100 cps/MBq were achieved with a four-head SPECT system. A hot rod with a diameter of 1.0 mm was resolved in the SPECT image of ultra-micro hot spot phantom.

physics.med-ph↗