SearcharxivSearch

arXiv subjects

Jordan Wheeler

Publications and source records attributed to Jordan Wheeler.

At least 19 recordsLinked to original sources

CCAT: Characterization of the first science-grade MKID array for the Prime-Cam 850 GHz module

The Fred Young Submillimeter Telescope (FYST) is a 6-meter crossed-Dragone telescope developed by the CCAT collaboration. Sited at 5600 m on Cerro Chajnantor in the Atacama Plateau of Chile, FYST aims to provide superior atmospheric transmission and a wide field of view for submillimeter observations. Prime-Cam is a first-generation instrument for FYST designed to house up to seven separate instrument modules. Among these, the 850 GHz module represents the highest-frequency band and is optimized for ultra-sensitive broadband polarimetry and imaging. This module is designed to deploy ~38,000 polarization-sensitive lumped-element titanium-nitride (TiN) microwave kinetic inductance detectors (MKIDs) across three arrays. Thus the 850 GHz module will have the most submillimeter MKIDs in a single instrument module to date. These detectors have adopted a novel two-octave design to maximize the multiplexing achieved using a RFSoC readout system. We review the design parameters and fabrication process for the first 850 GHz science-grade array. The preliminary measurements of the array show a fabrication yield of 99%, highlighting the successful application of the design and fabrication process. We further present the cryogenic characterization of the first full MKID array developed for the Prime-Cam 850 GHz module. Multiple tests were performed on the devices including resonator frequency mapping, quality factor measurements, optical load sweeps and noise performance. From these measurements, we discuss the measured optical efficiency, sensitivity, and uniformity across the array and the expected on-sky performance of the module. The 850 GHz module will be deployed for observing in 2027.

astro-ph.IM

CCAT: Design and Characterization of the 350 GHz Instrument Module

The CCAT Collaboration's Prime-Cam instrument will soon be deployed to the Fred Young Submillimeter Telescope (FYST) in Chile's Atacama Desert. Featuring prominently in Prime-Cam's calibration and early science observations will be the 350 GHz instrument module, a broadband camera that will field more than 10,000 microwave kinetic inductance detectors (KIDs) across three detector arrays. Forecasts show this module will be capable of making the most sensitive to-date measurements of polarized dust emission over a large fraction of the sky at this frequency, enabling new galactic polarization science and improved understanding of cosmological foregrounds. In this work we discuss the design of the 350 GHz instrument module, covering aspects of the optics, readout, and detector arrays. We then report on the results of in-lab testing of the fully-integrated module, achieving stable cryogenic performance with a 100 mK focal plane, high detector yield, and a passband comparable to designed specifications. Upon completion of these tests, this module was shipped to the telescope site in Chile for integration in Prime-Cam.

astro-ph.IM

CCAT: The 410 GHz camera module for FYST - design and testing of the MKID focal plane

Prime-Cam, the primary first-light instrument for the Fred Young Submillimeter Telescope (FYST) developed by the Cerro Chajnantor Atacama Telescope (CCAT) Collaboration, will accommodate seven modules. Here we describe the off-central 410 GHz imager/polarimeter. The 410 GHz instrument is a camera module for CCAT funded by the Canadian Foundation for Innovation, being developed as a collaboration between Dalhousie University, University of British Columbia (UBC), National Research Council (NRC) - Herzberg, and Duke University. With atmospheric loading in the 410 GHz window being significantly higher than at 350 GHz (but substantially lower than 850 GHz), we assess four MKID test devices with varying inductor volume for performance at 410 GHz. We propose a design for an array of ~6,700 horn-coupled TiN MKIDs optimized for use at 410 GHz, with a planned ~20,000 MKIDs over three arrays, exploring mapping speed versus detector number. We test the four MKID devices optically and assess optimal Qi/Qc and responsivity for the 410 GHz atmospheric window atop Cerro Chajnantor. The detectors will be designed in frequency to be efficiently readout with a second generation, two octave readout (based on the Xilinx RFSoC board), with over 4000 detectors per board.

astro-ph.IM

CCAT: Silicon-Platelet Feedhorns for Submillimeter Wavelengths

Silicon-platelet feedhorn arrays are an established technology at millimeter wavelengths that, for some applications, can provide significant advantages over traditional direct-machined metal feedhorns. The Prime-Cam focal planes operating in the 350 GHz ($\sim$860 $\mathrm{\mu}$m) and 850 GHz ($\sim$350 $\mathrm{\mu}$m) bands are anticipated to carry the first silicon-platelet feedhorn arrays to operate fully at submillimeter wavelengths, representing a significant step forward in the application of this technology. In particular, the feedhorns designed for operation in the 850 GHz band represent a 3x increase in frequency compared to previously demonstrated and deployed devices of this type. Here we present a demonstration of silicon-platelet feedhorns at these submillimeter wavelengths, including in-lab performance characterization. We present fabrication metrology, room-temperature beammaps, and cryogenic optical efficiency measurements where the feedhorns are coupled to prototype CCAT Prime-Cam detectors. We show that feedhorn performance measurements are well matched to simulation and compare that performance directly to traditional, direct-machined metal feedhorns.

astro-ph.IM

MM-SCALE: Grounded Multimodal Moral Reasoning via Scalar Judgment and Listwise Alignment

Vision-Language Models (VLMs) continue to struggle to make morally salient judgments in multimodal and socially ambiguous contexts. Prior works typically rely on binary or pairwise supervision, which often fail to capture the continuous and pluralistic nature of human moral reasoning. We present MM-SCALE (Multimodal Moral Scale), a large-scale dataset for aligning VLMs with human moral preferences through 5-point scalar ratings and explicit modality grounding. Each image-scenario pair is annotated with moral acceptability scores and grounded reasoning labels by humans using an interface we tailored for data collection, enabling listwise preference optimization over ranked scenario sets. By moving from discrete to scalar supervision, our framework provides richer alignment signals and finer calibration of multimodal moral reasoning. Experiments show that VLMs fine-tuned on MM-SCALE achieve higher ranking fidelity and more stable safety calibration than those trained with binary signals.

cs.CV

Development of Silicon Micromachined Waveguide Filter-Banks for On-Chip Spectrometers

Development of high-speed, spatial-mapping spectrometers in the millimeter and far-infrared frequencies would enable entirely new research avenues in astronomy and cosmology. An "on-chip" spectrometer is one such technology that could enable Line Intensity Mapping. Recent work has shown the promise of high-speed imaging; however, a limiting factor is that many of these devices suffer from low optical efficiency. Here we present the fabrication of a metalized, Si waveguide filter-bank fabricated using deep reactive ion etching for use in millimeter spectroscopy. Our design simultaneously provides high-density pixel packing, high optical efficiency, high spectral resolution, and is readily compatible with simple and multiplexable MKID arrays. Gold plated test waveguide and filter show excellent match to simulations with a measured resolving power of 263 and a loss quality factor of 1116 at room temperature. The results show promise for extending the measurements to larger, multi-wavelength designs.

astro-ph.IM

CCAT: Design, Implementation, and Testing of a System to Read Out over 10,000 280 GHz KIDs using RFSoC Electronics

Over the past decade, kinetic inductance detectors (KIDs) have emerged as a viable superconducting technology for astrophysics at millimeter and submillimeter wavelengths. KIDs spanning 210 - 850 GHz across seven instrument modules will be deployed in the Prime-Cam instrument of CCAT Observatory's Fred Young Submillimeter Telescope at an elevation of 5600 m on Cerro Chajnantor in Chile's Atacama Desert. The natural frequency-division multiplexed readout of KIDs allows hundreds of detectors to be coupled to a single radio frequency (RF) transmission line, but requires sophisticated warm readout electronics. The FPGA-based Xilinx ZCU111 radio frequency system on chip (RFSoC) offers a promising and flexible solution to the challenge of warm readout. CCAT uses custom packaged RFSoCs to read out KIDs in the Prime-Cam instrument. Each RFSoC can simultaneously read out four RF channels with up to 1,000 detectors spanning a 512 MHz bandwidth per channel using the current firmware. We use five RFSoCs to read out the >10,000 KIDs in the broadband 280 GHz instrument module. Here, we describe and demonstrate the readout hardware, software and pipeline for the RFSoC system. We present a detector position map of the 280 GHz module focal plane and preliminary averaged spectral responses of a small subset of detectors from the TiN and first Al arrays. These measurements demonstrate our ability to simultaneously readout thousands of detectors, validate the end-to-end performance of the readout and optical systems, and represent a critical step toward reading out the ~100,000 KIDs in Prime-Cam in its future full capacity configuration.

astro-ph.IM

CCAT: Magnetic Sensitivity Measurements of Kinetic Inductance Detectors

The CCAT Observatory is a ground-based submillimeter to millimeter experiment located on Cerro Chajnantor in the Atacama Desert, at an altitude of 5,600 meters. CCAT features the 6-meter Fred Young Submillimeter Telescope (FYST), which will cover frequency bands from 210 GHz to 850 GHz using its first-generation science instrument, Prime-Cam. The detectors used in Prime-Cam are feedhorn-coupled, lumped-element superconducting microwave kinetic inductance detectors (KIDs). The telescope will perform wide-area surveys at speeds on the order of degrees per second. During telescope operation, the KIDs are exposed to changes in the magnetic field caused by the telescope's movement through Earth's magnetic field and internal sources within the telescope. We present and compare measurements of the magnetic sensitivity of three different CCAT KID designs at 100 mK. The measurements are conducted in a dilution refrigerator (DR) with a set of room temperature Helmholtz coils positioned around the DR. We discuss the implications of these results for CCAT field operations.

astro-ph.IM

CCAT: Mod-Cam Cryogenic Performance and its Impact on 280 GHz KID Array Noise

The CCAT Observatory's Fred Young Submillimeter Telescope (FYST) is designed to observe submillimeter astronomical signals with high precision, using receivers fielding state-of-the-art kinetic inductance detector (KID) arrays. Mod-Cam, a first-light instrument for FYST, serves as a testbed for instrument module characterization, including detailed evaluation of thermal behavior under operating conditions prior to deploying modules in the larger Prime-Cam instrument. Prime-Cam is a first generation multi-band, wide-field camera for FYST, designed to field up to seven instrument modules and provide unprecedented sensitivity across a broad frequency range. We present results from two key laboratory characterizations: an "optically open" cooldown to validate the overall thermal performance of the cryostat, and a "cold load" cooldown to measure the effect of focal plane temperature stability on detector noise. During the optically open test, we achieved stable base temperatures of 1.5 K on the 1 K stage and 85 mK at the detector stage. In the cold load configuration, we measured a detector focal plane RMS temperature stability of 3.2e-5 K. From this stability measurement, we demonstrate that the equivalent power from focal plane thermal fluctuations is only 0.0040% of a 5pW incident photon power for aluminum detectors and 0.0023% for titanium-nitride detectors, a negligible level for CCAT science goals. This highlights the success of the cryogenic system design and thermal management.

astro-ph.IM

Compact Superconducting Kinetic Inductance Traveling Wave Parametric Amplifiers with On-chip rf Components

Quantum computing systems and fundamental physics experiments using superconducting technologies frequently require signal amplification chains operating near the quantum limit of added noise. Both Josephson parametric amplifiers (JPAs) and traveling wave parametric amplifiers (TWPAs) have been used as first-stage amplifiers to enable readout chains operating within a few quanta or less of the quantum limit. These devices are also presently entering the commercial industry. However, nearly all demonstrations and existing products require bulky external microwave components for interconnection and application of requisite biases. These components -- cabling interconnects, bias tees, directional couplers, and diplexers -- increase the overall amplifier footprint, installation complexity, and reduce already limited available cryogenic volumes. Additionally, these components introduce loss and reflections which impact the measurement efficiency and readout system noise performance; thus making it more difficult to operate near the quantum limit. Here we present the design and validation of microfabricated bias tees and directional couplers for operating three-wave mixing kinetic inductance TWPAs (KITs). We report the performance of KITs integrated with the microfabricated rf components. Using these devices we demonstrate reduction in the amplifier installation footprint by a factor of nearly five and elimination of all external, lossy microwave components previously required to operate a KIT. Our device displays a 2.8 GHz 3 dB bandwidth with a median true gain of 17.5 dB and median system noise of 3.4 quanta. These efforts represent the first full integration of all rf components mandatory for TWPA operation on-chip. Our results mark significant progress towards the miniaturization and simplification of parametric amplifier setups and will aid in their more widespread applicability.

quant-ph

Low two-level-system noise in hydrogenated amorphous silicon

At sub-Kelvin temperatures, two-level systems (TLS) present in amorphous dielectrics source a permittivity noise, degrading the performance of a wide range of devices using superconductive resonators such as qubits or kinetic inductance detectors. We report here on measurements of TLS noise in hydrogenated amorphous silicon (a-Si:H) films deposited by plasma-enhanced chemical vapor deposition (PECVD) in superconductive lumped-element resonators using parallel-plate capacitors (PPCs). The TLS noise results presented in this article for two recipes of a-Si:H improve on the best achieved in the literature by a factor >5 for a-Si:H and other amorphous dielectrics and are comparable to those observed for resonators deposited on crystalline dielectrics.

physics.ins-det

CCAT: LED Mapping and Characterization of the 280 GHz TiN KID Array

Prime-Cam, one of the primary instruments for the Fred Young Submillimeter Telescope (FYST) developed by the CCAT Collaboration, will house up to seven instrument modules, with the first operating at 280 GHz. Each module will include three arrays of superconducting microwave kinetic inductance detectors (KIDs). The first KID array fabricated for the 280 GHz module uses titanium-nitride (TiN) as the superconducting material and has 3,456 individual detectors, while the other two arrays use aluminum. This paper presents the design and laboratory characterization of the 280 GHz TiN array, which is cooled below its critical temperature to ~0.1 K and read out over six RF feedlines. LED mapping, a technique for matching the measured resonant frequency of a detector to its physical position, was performed on the array so that the results can be used to lithographically trim the KID capacitors and increase the yield of the array by reducing frequency collisions. We present the methods and results of LED mapping the 280 GHz TiN KID array before deployment on FYST.

astro-ph.IM

CCAT: A status update on the EoR-Spec instrument module for Prime-Cam

The Epoch of Reionization Spectrometer (EoR-Spec) is an upcoming Line Intensity Mapping (LIM) instrument designed to study the evolution of the early universe (z = 3.5 to 8) by probing the redshifted [CII] 158 $\mu$m fine-structure line from aggregates of galaxies. The [CII] emission is an excellent tracer of star formation since it is the dominant cooling line from neutral gas heated by OB star light and thus can be used to probe the reionization of the early Universe due to star formation. EoR-Spec will be deployed on Prime-Cam, a modular direct-detection receiver for the 6-meter Fred Young Submillimeter Telescope (FYST), currently under construction by CPI Vertex Antennentechnik GmbH and to be installed near the summit of Cerro Chajnantor in the Atacama Desert. This instrument features an image plane populated with more than 6500 Microwave Kinetic Inductance Detectors (MKIDs) that are illuminated by a 4-lens optical design with a cryogenic, scanning Fabry-Perot Interferometer (FPI) at the pupil of the optical system. The FPI is designed to provide a spectral resolving power of $R\sim100$ over the full spectral range of 210--420 GHz. EoR-Spec will tomographically survey the E-COSMOS and E-CDFS fields with a depth of about 4000 hours over a 5 year period. Here we give an update on EoR-Spec's final mechanical/optical design and the current status of fabrication, characterization and testing towards first light in 2026.

astro-ph.IM

CCAT: Nonlinear effects in 280 GHz aluminum kinetic inductance detectors

Prime-Cam, a first-generation science instrument for the Atacama-based Fred Young Submillimeter Telescope, is being built by the CCAT Collaboration to observe at millimeter and submillimeter wavelengths using kinetic inductance detectors (KIDs). Prime-Cam's 280 GHz instrument module will deploy with two aluminum-based KID arrays and one titanium nitride-based KID array, totaling approximately 10,000 detectors at the focal plane, all of which have been fabricated and are currently undergoing testing. One complication of fielding large arrays of KIDs under dynamic loading conditions is tuning the detector tone powers to maximize signal-to-noise while avoiding bifurcation due to the nonlinear kinetic inductance. For aluminum-based KIDs, this is further complicated by additional nonlinear effects which couple tone power to resonator quality factors and resonant frequencies. While both nonequilibrium quasiparticle dynamics and two-level system fluctuations have been shown to give rise to qualitatively similar distortions, modeling these effects alongside nonlinear kinetic inductance is inefficient when fitting thousands of resonators on-sky with existing models. For this reason, it is necessary to have a detailed understanding of the nonlinear effects across relevant detector loading conditions, including how they impact on on-sky noise and how to diagnose the detector's relative performance. We present a study of the competing nonlinearities seen in Prime-Cam's 280 GHz aluminum KIDs, with a particular emphasis on the resulting distortions to the resonator line shape and how these impact detector parameter estimation.

astro-ph.IM

CCAT: Comparisons of 280 GHz TiN and Al Kinetic Inductance Detector Arrays

The CCAT Collaboration's six-meter Fred Young Submillimeter Telescope is scheduled to begin observing in the Chilean Atacama in 2025, targeting a variety of science goals throughout cosmic history. Prime-Cam is a 1.8-meter diameter cryostat that will host up to seven independent instrument modules designed for simultaneous spectroscopic and broadband, polarimetric surveys at millimeter to submillimeter wavelengths. The first of these instrument modules, the 280 GHz module, will include ${\sim}$10,000 kinetic inductance detectors (KIDs) across three arrays. While the first array was fabricated out of tri-layer TiN/Ti/TiN, the other two arrays were fabricated out of a single layer of Al. This combination of materials within the same instrument provides a unique opportunity to directly compare the performance and noise properties of two different detector materials that are seeing increasing use within the field. We present preliminary comparisons here based on lab testing, along with a discussion of the potential impacts on operation when observing and translating raw data to science-grade maps.

astro-ph.IM

Kinetic inductance current sensor for visible to near-infrared wavelength transition-edge sensor readout

Single-photon detectors based on the superconducting transition-edge sensor are used in a number of visible to near-infrared applications, particularly for photon-number-resolving measurements in quantum information science. To be practical for large-scale spectroscopic imaging or photonic quantum computing applications, the size of visible to near-infrared transition-edge sensor arrays and their associated readouts must be increased from a few pixels to many thousands. In this manuscript, we introduce the kinetic inductance current sensor, a scalable readout technology that exploits the nonlinear kinetic inductance in a superconducting resonator to make sensitive current measurements. Kinetic inductance current sensors can replace superconducting quantum interference devices for many applications because of their ability to measure fast, high slew-rate signals, their compatibility with standard microwave frequency-division multiplexing techniques, and their relatively simple fabrication. Here, we demonstrate the readout of a visible to near-infrared transition-edge sensor using a kinetic inductance current sensor with 3.7 MHz of bandwidth. We measure a readout noise of 1.4 pA/$\sqrt{\text{Hz}}$, considerably below the detector noise at frequencies of interest, and an energy resolution of $(0.137 \pm 0.001)$ eV at 0.8 eV, comparable to resolutions observed with non-multiplexed superconducting quantum interference device readouts.

physics.ins-det

CCAT-prime: Design of the Mod-Cam receiver and 280 GHz MKID instrument module

Mod-Cam is a first light and commissioning instrument for the CCAT-prime project's six-meter aperture Fred Young Submillimeter Telescope (FYST), currently under construction at 5600 m on Cerro Chajnantor in Chile's Atacama Desert. Prime-Cam, a first-generation science instrument for FYST, will deliver over ten times greater mapping speed than current and near-term facilities for unprecedented 280-850 GHz broadband and spectroscopic measurements with microwave kinetic inductance detectors (MKIDs). CCAT-prime will address a suite of science goals, from Big Bang cosmology to star formation and galaxy evolution over cosmic time. Mod-Cam deployment on FYST with a 280 GHz instrument module containing MKID arrays is planned for early science observations in 2024. Mod-Cam will be used to test instrument modules for Prime-Cam, which can house up to seven instrument modules. We discuss the design and status of the 0.9 m diameter, 1.8 m long Mod-Cam receiver and 40 cm diameter 280 GHz instrument module, with cold stages at 40 K, 4 K, 1 K, and 100 mK. We also describe the instrument module's cryogenic readout designs to enable the readout of more than 10,000 MKIDs across 18 networks.

astro-ph.IM

CCAT-prime: Characterization of the First 280 GHz MKID Array for Prime-Cam

The Prime-Cam receiver on the Fred Young Submillimeter Telescope for the CCAT-prime project aims to address important astrophysical and cosmological questions with sensitive broadband, polarimetric, and spectroscopic measurements. The primary frequency bands in development include 280, 350, and 850 GHz for the polarization-sensitive broadband channels and 210--420 GHz for the spectrometers. Microwave kinetic inductance detectors (MKIDs) are a natural choice of detector technology for the simplicity in multiplexed readout needed for large format arrays at these high frequencies. We present here the initial lab characterization of the feedhorn-coupled 280 GHz polarimetric MKID array, and outline the plans for the subsequent MKID arrays and the development of the testbed to characterize them.

astro-ph.IM