Searcharxiv⌕ Search

arXiv subjects

José M. Saavedra

Publications and source records attributed to José M. Saavedra.

2 recordsLinked to original sources

B-MIM: Biased Masked Image Modeling for Generalizable Segmentation of Fine-Grained Anatomical Structures

Self-supervised pretraining enables transferable representations for medical imaging, yet most CT encoders remain biased toward coarse semantic understanding, limiting their sensitivity to fine-grained anatomical structures such as vessels or small tumors. In this paper, we introduce Biased Masked Image Modeling (B-MIM), a modification of the iBOT objective that stochastically reduces global semantic alignment to prioritize local patch reconstruction. This bias encourages the encoder to capture high-frequency morphological details and structural continuity. We curate a multi-institutional CT abdominal dataset of 9,955 filtered studies from 17 public sources and pretrain a 3D Swin Transformer backbone using B-MIM. Across inter-dataset experiments on liver vessel segmentation, the proposed encoder improves topological fidelity (clDice) and achieves competitive Dice scores in tumor segmentation, compared to fully fine-tuned baselines, despite updating only a fraction of the parameters. Our results suggest that reducing global semantic pressure during pretraining enhances generalization to intricate anatomical structures.

cs.CV↗

AST-n: A Fast Sampling Approach for Low-Dose CT Reconstruction using Diffusion Models

Low-dose CT (LDCT) protocols reduce radiation exposure but increase image noise, compromising diagnostic confidence. Diffusion-based generative models have shown promise for LDCT denoising by learning image priors and performing iterative refinement. In this work, we introduce AST-n, an accelerated inference framework that initiates reverse diffusion from intermediate noise levels, and integrate high-order ODE solvers within conditioned models to further reduce sampling steps. We evaluate two acceleration paradigms--AST-n sampling and standard scheduling with high-order solvers -- on the Low Dose CT Grand Challenge dataset, covering head, abdominal, and chest scans at 10-25 % of standard dose. Conditioned models using only 25 steps (AST-25) achieve peak signal-to-noise ratio (PSNR) above 38 dB and structural similarity index (SSIM) above 0.95, closely matching standard baselines while cutting inference time from ~16 seg to under 1 seg per slice. Unconditional sampling suffers substantial quality loss, underscoring the necessity of conditioning. We also assess DDIM inversion, which yields marginal PSNR gains at the cost of doubling inference time, limiting its clinical practicality. Our results demonstrate that AST-n with high-order samplers enables rapid LDCT reconstruction without significant loss of image fidelity, advancing the feasibility of diffusion-based methods in clinical workflows.

cs.CV↗