A wearable, stretchable radio-frequency coil for extremity imaging in low-field MRI systems

Purpose: To develop a wearable, stretchable radio-frequency (RF) coil that conforms to the extremities and improves the filling factor in low-field MRI. Methods: A stretchable solenoid RF coil was fabricated by stitching a sinusoidally arranged Litz-wire conductor onto an elastic textile. The coil was compared with four rigid coils, including two routinely used designs and two prototypes designed to isolate the effects of conductor material and stretchability. Performance was characterized through quality-factor, loading-factor, transmit-efficiency, and image-based signal-to-noise ratio (SNR) measurements. Phantom and in-vivo knee experiments for one volunteer were performed using two portable MRI systems operating at 3.53 and 3.04 MHz. Results: The electrical performance of the selected Litz wire decreased with increasing frequency, becoming a slight disadvantage at 3.53 MHz. Nevertheless, the stretchable coil provided the highest phantom SNR in both systems, exceeding that of the best-performing rigid coil by approximately 8 % at 3.53 MHz and 20 % at 3.04 MHz. In vivo, its global SNR was 5 % lower than that of the best rigid coil at 3.53 MHz and 19 % higher at 3.04 MHz. Compared with the larger rigid coil required when knee positioning is constrained, the corresponding SNR improvements were approximately 18 % and 80 %. Conclusion: Anatomical conformity can compensate for the frequency-dependent electrical limitations of Litz wire in stretchable low-field RF coils. The proposed design provided SNR comparable to or greater than the best rigid designs while facilitating coil placement in subjects for whom smaller rigid coils may be impractical.

physics.med-ph↗

ezyMRI: How to build an MRI machine from scratch -- Experience from a four-day hackathon

Nuclear magnetic resonance instruments are becoming available to the do-it-yourself community. The challenges encountered in the endeavor to build a magnetic resonance imaging instrument from scratch were confronted in a four-day hackathon at Singapore University of Technology and Design in spring 2024. One day was devoted to educational lectures and three days to system construction and testing. Seventy young researchers from all parts of the world formed six teams focusing on magnet, gradient coil, RF coil, console, system integration, and design, which together produced a working MRI instrument in three days. The different steps, encountered challenges, and their solutions are reported.

physics.med-ph↗

Zero-echo-time sequences in highly inhomogeneous fields

Zero echo time (ZTE) sequences have proven a powerful tool for Magnetic Resonance Imaging (MRI) of ultrashort T2 tissues, but they fail to produce useful images in the presence of strong field inhomogeneities. Here we present a method to correct artifacts induced by strong B0 inhomogeneities in non-Cartesian sequences, based on magnetic field maps obtained from the phase difference between two fast pointwise acquisitions. These are free of geometric distortions and can be used for model based image reconstruction with iterative algebraic techniques. In this paper, we show that distortions and artifacts coming from inhomogeneites in B0 are largely reverted by our method, as opposed to standard Conjugate Phase reconstructions. We base this technique on a Single-Point Double-Shot (SPDS) approach, and we have shown it to work even for intra-voxel bandwidths (determined by B0 inhomogeneities) comparable to the encoding bandwidth (determined by the gradient fields). We benchmark the performance of SPDS for ZTE acquisitions, which can be exploited for e.g. dental imaging in affordable low-field MRI systems. Furthermore, SPDS can be used for arbitrary pulse sequences and it may prove useful for extreme magnet geometries, as in e.g. single-sided MRI.

physics.med-ph↗