Characterization of a TES-based Anti-Coincidence Detector for Future Large Field-of-View X-ray Calorimetry Missions

Microcalorimeter instruments aboard future X-ray observatories will require an anti-coincidence (anti-co) detector to veto charged particle events and reduce the non-X-ray background. We have developed a large-format, TES-based prototype anti-coincidence detector that is particularly suitable for use with spatially-extended (~ 10 cm^2}) TES microcalorimeter arrays, as would be used for a future large field-of-view X-ray missions. This prototype was developed in the context of the Line Emission Mapper (LEM) probe concept, which required a ~ 14 cm^2 anti-co detector with > 95% live time and a low-energy threshold below 20 keV. Our anti-co design employs parallel networks of quasiparticle-trap-assisted electrothermal feedback TESs (QETs) to detect the athermal phonon signal produced in the detector substrate by incident charged particles. We developed multiple prototype anti-co designs featuring 12 channels and up to 6300 QETs. Here we focus on a design utilizing tungsten TESs and present characterization results. Broad energy range measurements have been performed (4.1 keV -- 5.5 MeV). Based on noise and responsivity measurements, the implied low-energy threshold is < 1 keV and a live time fraction of > 96% can be achieved up to 5.5 MeV. We also find evidence of mm-scale-or-better spatial resolution and discuss the potential utility of this for future missions. Finally, we discuss the early development of a soild-state physics model of the anti-co towards understanding phonon propagation and quasiparticle production in the detector.

astro-ph.IM

Line Emission Mapper (LEM): Probing the physics of cosmic ecosystems

The Line Emission Mapper (LEM) is an X-ray Probe for the 2030s that will answer the outstanding questions of the Universe's structure formation. It will also provide transformative new observing capabilities for every area of astrophysics, and to heliophysics and planetary physics as well. LEM's main goal is a comprehensive look at the physics of galaxy formation, including stellar and black-hole feedback and flows of baryonic matter into and out of galaxies. These processes are best studied in X-rays, and emission-line mapping is the pressing need in this area. LEM will use a large microcalorimeter array/IFU, covering a 30x30' field with 10" angular resolution, to map the soft X-ray line emission from objects that constitute galactic ecosystems. These include supernova remnants, star-forming regions, superbubbles, galactic outflows (such as the Fermi/eROSITA bubbles in the Milky Way and their analogs in other galaxies), the Circumgalactic Medium in the Milky Way and other galaxies, and the Intergalactic Medium at the outskirts and beyond the confines of galaxies and clusters. LEM's 1-2 eV spectral resolution in the 0.2-2 keV band will make it possible to disentangle the faintest emission lines in those objects from the bright Milky Way foreground, providing groundbreaking measurements of the physics of these plasmas, from temperatures, densities, chemical composition to gas dynamics. While LEM's main focus is on galaxy formation, it will provide transformative capability for all classes of astrophysical objects, from the Earth's magnetosphere, planets and comets to the interstellar medium and X-ray binaries in nearby galaxies, AGN, and cooling gas in galaxy clusters. In addition to pointed observations, LEM will perform a shallow all-sky survey that will dramatically expand the discovery space.

astro-ph.IM

First Flight Performance of the Micro-X Microcalorimeter X-Ray Sounding Rocket

The flight of the Micro-X sounding rocket on July 22, 2018 marked the first operation of Transition-Edge Sensors and their SQUID readouts in space. The instrument combines the microcalorimeter array with an imaging mirror to take high-resolution spectra from extended X-ray sources. The first flight target was the Cassiopeia~A Supernova Remnant. While a rocket pointing malfunction led to no time on-target, data from the flight was used to evaluate the performance of the instrument and demonstrate the flight viability of the payload. The instrument successfully achieved a stable cryogenic environment, executed all flight operations, and observed X-rays from the on-board calibration source. The flight environment did not significantly affect the performance of the detectors compared to ground operation. The flight provided an invaluable test of the impact of external magnetic fields and the instrument configuration on detector performance. This flight provides a milestone in the flight readiness of these detector and readout technologies, both of which have been selected for future X-ray observatories.

astro-ph.IM

Development of frequency domain multiplexing for the X-ray Integral Field Unit (X-IFU) on the Athena

We are developing the frequency domain multiplexing (FDM) read-out of transition-edge sensor (TES) microcalorimeters for the X-ray Integral Field Unit (X-IFU) instrument on board of the future European X-Ray observatory Athena. The X-IFU instrument consists of an array of $\sim$3840 TESs with a high quantum efficiency ($>$90 \%) and spectral resolution $ΔE$=2.5 eV $@$ 7 keV ($E/ΔE\sim$2800). FDM is currently the baseline readout system for the X-IFU instrument. Using high quality factor LC filters and room temperature electronics developed at SRON and low-noise two stage SQUID amplifiers provided by VTT, we have recently demonstrated good performance with the FDM readout of Mo/Au TES calorimeters with Au/Bi absorbers. An integrated noise equivalent power resolution of about 2.0 eV at 1.7 MHz has been demonstrated with a pixel from a new TES array from NASA/Goddard (GSFC-A2). We have achieved X-ray energy resolutions $\sim$2.5 eV at AC bias frequency at 1.7 MHz in the single pixel read-out. We have also demonstrated for the first time an X-ray energy resolution around 3.0 eV in a 6 pixel FDM read-out with TES array (GSFC-A1). In this paper we report on the single pixel performance of these microcalorimeters under MHz AC bias, and further results of the performance of these pixels under FDM.