SearcharxivSearch

arXiv subjects

Joseph W. Fowler

Publications and source records attributed to Joseph W. Fowler.

At least 19 recordsLinked to original sources

Using a 4-megapixel hybrid photon counting detector for fast, lab-based nanoscale x-ray tomography

Hybrid photon counting detectors (HPCDs) have unlocked new capabilities for x-ray-based measurements at synchrotrons around the world in the last 30 years. By leveraging independently optimized sensor and readout layers, they offer high quantum efficiency ($> 80 \%$), ultra-low dark counts, sub-pixel point-spread function, and high count rates ($> 10^{6}$ counts per pixel per second). Furthermore, their small pixel size and large active area endow them with excellent coverage and resolution for both real-space and reciprocal space imaging. Here, we demonstrate that HPCDs are also well-suited for laboratory-based nanoscale x-ray tomography (nano-xCT). We perform nano-xCT on an integrated circuit fabricated at the 130-nm node and produce a 3D reconstruction with 40 times more photons collected 20 times faster than in this group's previous work, for an overall speedup of 800$\times$. We review the technical considerations of using an HPCD for tabletop tomography. We quantify our reconstruction image quality using well-established metrics, including the modulation transfer function (MTF), Fourier shell correlation (FSC), and contrast-to-noise (CNR), to validate our choice of experimental parameters that provide sufficient resolution and imaging speed. Using these metrics, we determine that even under current experimental conditions, 160 nm wiring features are reconstructed at 75-80 nm spatial resolution.

physics.ins-det

Detecting and Correcting Gain Jumps in TES Microcalorimeters

Arrays of microcalorimeters based on transition-edge sensors (TESs) are being actively deployed to laboratories all over the world. A TES microcalorimeter array produces very large quantities of data and users of these devices have varying levels of experience, so it is important to provide robust software for data acquisition and analysis that can function with minimal user supervision. This software should be capable of addressing common phenomena that can adversely affect spectrum quality. Gain jumping is one such phenomenon that is characterized by abrupt changes in the gain of a device. Left unaddressed, gain jumps can degrade spectra by introducing false peaks. We are not aware of any previously published methods for resetting gain jumps during data acquisition or existing algorithms for correcting data that is degraded by gain jumps. We have developed automated methods for detecting and correcting gain jumps in gamma-ray TES microcalorimeters. We present a procedure for resetting gain jumps during a live data acquisition that involves briefly driving the TES into its normal state using the bias current. We also describe an algorithm for locating gain jumps and identifying unique gain states within existing microcalorimeter data. Finally, we provide a possible approach for correcting gain jumps after they have been identified.

physics.ins-det

Kinetic inductance current sensor for visible to near-infrared wavelength transition-edge sensor readout

Single-photon detectors based on the superconducting transition-edge sensor are used in a number of visible to near-infrared applications, particularly for photon-number-resolving measurements in quantum information science. To be practical for large-scale spectroscopic imaging or photonic quantum computing applications, the size of visible to near-infrared transition-edge sensor arrays and their associated readouts must be increased from a few pixels to many thousands. In this manuscript, we introduce the kinetic inductance current sensor, a scalable readout technology that exploits the nonlinear kinetic inductance in a superconducting resonator to make sensitive current measurements. Kinetic inductance current sensors can replace superconducting quantum interference devices for many applications because of their ability to measure fast, high slew-rate signals, their compatibility with standard microwave frequency-division multiplexing techniques, and their relatively simple fabrication. Here, we demonstrate the readout of a visible to near-infrared transition-edge sensor using a kinetic inductance current sensor with 3.7 MHz of bandwidth. We measure a readout noise of 1.4 pA/$\sqrt{\text{Hz}}$, considerably below the detector noise at frequencies of interest, and an energy resolution of $(0.137 \pm 0.001)$ eV at 0.8 eV, comparable to resolutions observed with non-multiplexed superconducting quantum interference device readouts.

physics.ins-det

Spectroscopic measurements and models of energy deposition in the substrate of quantum circuits by natural ionizing radiation

Naturally occurring background radiation is a source of correlated decoherence events in superconducting qubits that will challenge error-correction schemes. To characterize the radiation environment in an unshielded laboratory, we performed broadband, spectroscopic measurements of background events in silicon substrates located inside a millikelvin refrigerator, an environment representative of superconducting qubit systems. We measured the background spectra in silicon substrates of two thicknesses, 0.5 mm and 1.5 mm, and obtained the average event rate and the integrated power deposition. In a 25 mm^2 area and the thinner substrate, these values are 0.023 events per second and 4.9 keV/s, counting events that deposit at least 40 keV. We find the background spectrum to be nearly featureless. Its intensity decreases by a factor of 40,000 between 100 keV and 3 MeV for silicon substrates 0.5 mm thick. We find the cryogenic measurements to be in good agreement with predictions based on measurements of the terrestrial gamma-ray flux, published models of cosmic-ray fluxes, a crude model of the cryostat, and radiation-transport simulations. No free parameters are required to predict the background spectra in the silicon substrates. The good agreement between measurements and predictions allow assessment of the relative contributions of terrestrial and cosmic background sources and their dependence on substrate thickness. Our spectroscopic measurements are performed with superconducting microresonators that transduce deposited energy to a readily detectable electrical signal. We find that gamma-ray emissions from radioisotopes are responsible for the majority of events depositing E<1.5 MeV, while nucleons among the cosmic-ray secondary particles cause most events that deposit more energy. These results suggest several paths to reducing the impact of background radiation on quantum circuits.

quant-ph

Nanoscale Three-Dimensional Imaging of Integrated Circuits using a Scanning Electron Microscope and Transition-Edge Sensor Spectrometer

X-ray nanotomography is a powerful tool for the characterization of nanoscale materials and structures, but is difficult to implement due to competing requirements on X-ray flux and spot size. Due to this constraint, state-of-the-art nanotomography is predominantly performed at large synchrotron facilities. We present a laboratory-scale nanotomography instrument that achieves nanoscale spatial resolution while changing the limitations of conventional tomography tools. The instrument combines the electron beam of a scanning electron microscope (SEM) with the precise, broadband X-ray detection of a superconducting transition-edge sensor (TES) microcalorimeter. The electron beam generates a highly focused X-ray spot in a metal target held micrometers away from the sample of interest, while the TES spectrometer isolates target photons with high signal-to-noise. This combination of a focused X-ray spot, energy-resolved X-ray detection, and unique system geometry enable nanoscale, element-specific X-ray imaging in a compact footprint. The proof-of-concept for this approach to X-ray nanotomography is demonstrated by imaging 160 nm features in three dimensions in 6 layers of a Cu-SiO2 integrated circuit, and a path towards finer resolution and enhanced imaging capabilities is discussed.

physics.ins-det

A tabletop x-ray tomography instrument for nanometer-scale imaging: demonstration of the 1,000-element transition-edge sensor subarray

We report on the 1,000-element transition-edge sensor (TES) x-ray spectrometer implementation of the TOMographic Circuit Analysis Tool (TOMCAT). TOMCAT combines a high spatial resolution scanning electron microscope (SEM) with a highly efficient and pixelated TES spectrometer to reconstruct three-dimensional maps of nanoscale integrated circuits (ICs). A 240-pixel prototype spectrometer was recently used to reconstruct ICs at the 130 nm technology node, but to increase imaging speed to more practical levels, the detector efficiency needs to be improved. For this reason, we are building a spectrometer that will eventually contain 3,000 TES microcalorimeters read out with microwave superconducting quantum interference device (SQUID) multiplexing, and we currently have commissioned a 1,000 TES subarray. This still represents a significant improvement from the 240-pixel system and allows us to begin characterizing the full spectrometer performance. Of the 992 maximimum available readout channels, we have yielded 818 devices, representing the largest number of TES x-ray microcalorimeters simultaneously read out to date. These microcalorimeters have been optimized for pulse speed rather than purely energy resolution, and we measure a FWHM energy resolution of 14 eV at the 8.0 keV Cu K$α$ line.

physics.ins-det

Design of a 3000-pixel transition-edge sensor x-ray spectrometer for microcircuit tomography

Feature sizes in integrated circuits have decreased substantially over time, and it has become increasingly difficult to three-dimensionally image these complex circuits after fabrication. This can be important for process development, defect analysis, and detection of unexpected structures in externally sourced chips, among other applications. Here, we report on a non-destructive, tabletop approach that addresses this imaging problem through x-ray tomography, which we uniquely realize with an instrument that combines a scanning electron microscope (SEM) with a transition-edge sensor (TES) x-ray spectrometer. Our approach uses the highly focused SEM electron beam to generate a small x-ray generation region in a carefully designed target layer that is placed over the sample being tested. With the high collection efficiency and resolving power of a TES spectrometer, we can isolate x-rays generated in the target from background and trace their paths through regions of interest in the sample layers, providing information about the various materials along the x-ray paths through their attenuation functions. We have recently demonstrated our approach using a 240 Mo/Cu bilayer TES prototype instrument on a simplified test sample containing features with sizes of $\sim$1 $μ$m. Currently, we are designing and building a 3000 Mo/Au bilayer TES spectrometer upgrade, which is expected to improve the imaging speed by factor of up to 60 through a combination of increased detector number and detector speed.

physics.ins-det

Absolute Energy Measurements with Superconducting Transition-Edge Sensors for Muonic X-ray Spectroscopy at 44 keV

Superconducting transition-edge sensor (TES) microcalorimeters have great utility in x-ray applications owing to their high energy resolution, good collecting efficiency and the feasibility of being multiplexed into large arrays. In this work, we develop hard x-ray TESs to measure the absolute energies of muonic-argon ($μ$-Ar) transition lines around 44 keV and 20 keV. TESs with sidecar absorbers of different heat capacities were fabricated and characterized for their energy resolution and calibration uncertainty. We achieved ~ 1 eV absolute energy measurement accuracy at 44 keV, and < 12 eV energy resolution at 17.5 keV.

physics.ins-det

Quantification of 242Pu with a Microcalorimeter Gamma Spectrometer

We report measurements of the 103-keV and 159-keV gamma ray signatures of 242Pu using microcalorimetry. This is the first observation of these gamma rays in a non-destructive measurement of an unprepared sample, and so represents an important advance in nuclear material accountancy. The measurement campaign also serves as the first demonstration of a field campaign with a portable microcalorimeter gamma-ray spectrometer. For the 103-keV gamma ray we report an improved centroid energy and emission probability.

physics.ins-det

Absolute energies and emission line shapes of the L x-ray transitions of lanthanide metals

We use an array of transition-edge sensors, cryogenic microcalorimeters with 4 eV energy resolution, to measure L x-ray emission-line profiles of four elements of the lanthanide series: praseodymium, neodymium, terbium, and holmium. The spectrometer also surveys numerous x-ray standards in order to establish an absolute-energy calibration traceable to the International System of Units for the energy range 4 keV to 10 keV. The new results include emission line profiles for 97 lines, each expressed as a sum of one or more Voigt functions; improved absolute energy uncertainty on 71 of these lines relative to existing reference data; a median uncertainty on the peak energy of 0.24 eV, four to ten times better than the median of prior work; and 6 lines that lack any measured values in existing reference tables. The 97 lines comprise nearly all of the most intense L lines from these elements under broad-band x-ray excitation. The work improves on previous measurements made with a similar cryogenic spectrometer by the use of sensors with better linearity in the absorbed energy and a gold x-ray absorbing layer that has a Gaussian energy-response function. It also employs a novel sample holder that enables rapid switching between science targets and calibration targets with excellent gain balancing. Most of the results for peak energy values shown here should be considered as replacements for the currently tabulated standard reference values, while the line shapes given here represent a significant expansion of the scope of available reference data.

physics.ins-det

Results from the Atacama B-mode Search (ABS) Experiment

The Atacama B-mode Search (ABS) is an experiment designed to measure cosmic microwave background (CMB) polarization at large angular scales ($\ell>40$). It operated from the ACT site at 5190~m elevation in northern Chile at 145 GHz with a net sensitivity (NEQ) of 41 $μ$K$\sqrt{\rm s}$. It employed an ambient-temperature sapphire half-wave plate rotating at 2.55 Hz to modulate the incident polarization signal and reduce systematic effects. We report here on the analysis of data from a 2400 deg$^2$ patch of sky centered at declination $-42^\circ$ and right ascension $25^\circ$. We perform a blind analysis. After unblinding, we find agreement with the Planck TE and EE measurements on the same region of sky. We marginally detect polarized dust emission and give an upper limit on the tensor-to-scalar ratio of $r<2.3$ (95% cl) with the equivalent of 100 on-sky days of observation. We also present a new measurement of the polarization of Tau A and introduce new methods associated with HWP-based observations.

astro-ph.CO

Microstructure analysis of bismuth absorbers for transition-edge sensor X-ray microcalorimeters

Transition-edge sensors (TESs) as microcalorimeters offer high resolving power, owning to their sharp response and low operating temperature. In the hard X-ray regime and above, the demand for high quantum-efficiency requires the use of absorbers. Bismuth (Bi), owing to its low heat carrier density and high X-ray stopping power, has been widely used as an absorber material for TESs. However, distinct spectral responses have been observed for Bi absorbers deposited via evaporation versus electroplating. Evaporated Bi absorbers are widely observed to have a non-Gaussian tail on the low energy side of measured spectra. In this study, we fabricated Bi absorbers via these two methods, and performed microstructure analysis using scanning electron microscopy (SEM) and X-ray diffraction microscopy. The two types of material showed the same crystallographic structure, but the grain size of the evaporated Bi was about 40 times smaller than that of the electroplated Bi. This distinction in grain size is likely to be the cause of their different spectral responses.

physics.ins-det

Eliminating the non-Gaussian spectral response of X-ray absorbers for transition-edge sensors

Transition-edge sensors (TES) as microcalorimeters for high-energy-resolution X-ray spectroscopy are often fabricated with an absorber made of materials with high Z (for X-ray stopping power) and low heat capacity (for high resolving power). Bismuth represents one of the most compelling options. TESs with evaporated bismuth absorbers have shown spectra with undesirable and unexplained low-energy tails. We have developed TESs with electroplated bismuth absorbers over a gold layer that are not afflicted by this problem and that retain the other positive aspects of this material. To better understand these phenomena, we have studied a series of TESs with gold, gold/evaporated bismuth, and gold/electroplated bismuth absorbers, fabricated on the same die with identical thermal coupling. We show that bismuth morphology is linked to the spectral response of X-ray TES microcalorimeters.

physics.ins-det

L-Edge Spectroscopy of Dilute, Radiation-Sensitive Systems Using a Transition-Edge-Sensor Array

We present X-ray absorption spectroscopy and resonant inelastic X-ray scattering (RIXS) measurements on the iron L-edge of 0.5 mM aqueous ferricyanide. These measurements demonstrate the ability of high-throughput transition-edge-sensor (TES) spectrometers to access the rich soft X-ray (100-2000eV) spectroscopy regime for dilute and radiation-sensitive samples. Our low-concentration data are in agreement with high-concentration measurements recorded by conventional grating-based spectrometers. These results show that soft X-ray RIXS spectroscopy acquired by high-throughput TES spectrometers can be used to study the local electronic structure of dilute metal-centered complexes relevant to biology, chemistry and catalysis. In particular, TES spectrometers have a unique ability to characterize frozen solutions of radiation- and temperature-sensitive samples.

physics.ins-det

The Atacama Cosmology Telescope: CMB Polarization at $200<\ell<9000$

We report on measurements of the cosmic microwave background (CMB) and celestial polarization at 146 GHz made with the Atacama Cosmology Telescope Polarimeter (ACTPol) in its first three months of observing. Four regions of sky covering a total of 270 square degrees were mapped with an angular resolution of $1.3'$. The map noise levels in the four regions are between 11 and 17 $μ$K-arcmin. We present TT, TE, EE, TB, EB, and BB power spectra from three of these regions. The observed E-mode polarization power spectrum, displaying six acoustic peaks in the range $200<\ell<3000$, is an excellent fit to the prediction of the best-fit cosmological models from WMAP9+ACT and Planck data. The polarization power spectrum, which mainly reflects primordial plasma velocity perturbations, provides an independent determination of cosmological parameters consistent with those based on the temperature power spectrum, which results mostly from primordial density perturbations. We find that without masking any point sources in the EE data at $\ell<9000$, the Poisson tail of the EE power spectrum due to polarized point sources has an amplitude less than $2.4$ $μ$K$^2$ at $\ell = 3000$ at 95\% confidence. Finally, we report that the Crab Nebula, an important polarization calibration source at microwave frequencies, has 8.7\% polarization with an angle of $150.7^\circ \pm 0.6^\circ$ when smoothed with a $5'$ Gaussian beam.

astro-ph.CO

Maximum-likelihood fits to histograms for improved parameter estimation

Straightforward methods for adapting the familiar chi^2 statistic to histograms of discrete events and other Poisson distributed data generally yield biased estimates of the parameters of a model. The bias can be important even when the total number of events is large. For the case of estimating a microcalorimeter's energy resolution at 6 keV from the observed shape of the Mn K-alpha fluorescence spectrum, a poor choice of chi^2 can lead to biases of at least 10% in the estimated resolution when up to thousands of photons are observed. The best remedy is a Poisson maximum-likelihood fit, through a simple modification of the standard Levenberg-Marquardt algorithm for chi^2 minimization. Where the modification is not possible, another approach allows iterative approximation of the maximum-likelihood fit.

physics.data-an

High-resolution gamma-ray spectroscopy with a microwave-multiplexed transition-edge sensor array

We demonstrate very high resolution photon spectroscopy with a microwave-multiplexed two-pixel transition-edge sensor (TES) array. We measured a $^{153}$Gd photon source and achieved an energy resolution of 63 eV full-width-at-half-maximum at 97 keV and an equivalent readout system noise of 86 pA/$\sqrt{\text{Hz}}$ at the TES. The readout circuit consists of superconducting microwave resonators coupled to radio-frequency superconducting-quantum-interference-devices (SQUID) and transduces changes in input current to changes in phase of a microwave signal. We use flux-ramp modulation to linearize the response and evade low-frequency noise. This demonstration establishes one path for the readout of cryogenic X-ray and gamma-ray sensor arrays with more than $10^3$ elements and spectral resolving powers $R=λ/Δλ> 10^3$.

physics.ins-det

The Atacama Cosmology Telescope: Cosmological parameters from three seasons of data

We present constraints on cosmological and astrophysical parameters from high-resolution microwave background maps at 148 GHz and 218 GHz made by the Atacama Cosmology Telescope (ACT) in three seasons of observations from 2008 to 2010. A model of primary cosmological and secondary foreground parameters is fit to the map power spectra and lensing deflection power spectrum, including contributions from both the thermal Sunyaev-Zeldovich (tSZ) effect and the kinematic Sunyaev-Zeldovich (kSZ) effect, Poisson and correlated anisotropy from unresolved infrared sources, radio sources, and the correlation between the tSZ effect and infrared sources. The power ell^2 C_ell/2pi of the thermal SZ power spectrum at 148 GHz is measured to be 3.4 +\- 1.4 muK^2 at ell=3000, while the corresponding amplitude of the kinematic SZ power spectrum has a 95% confidence level upper limit of 8.6 muK^2. Combining ACT power spectra with the WMAP 7-year temperature and polarization power spectra, we find excellent consistency with the LCDM model. We constrain the number of effective relativistic degrees of freedom in the early universe to be Neff=2.79 +\- 0.56, in agreement with the canonical value of Neff=3.046 for three massless neutrinos. We constrain the sum of the neutrino masses to be Sigma m_nu < 0.39 eV at 95% confidence when combining ACT and WMAP 7-year data with BAO and Hubble constant measurements. We constrain the amount of primordial helium to be Yp = 0.225 +\- 0.034, and measure no variation in the fine structure constant alpha since recombination, with alpha/alpha0 = 1.004 +/- 0.005. We also find no evidence for any running of the scalar spectral index, dns/dlnk = -0.004 +\- 0.012.

astro-ph.CO