Birth of the Coil: another Milestone towards a fully reproducible low-field MRI scanner for head-imaging

Low-field magnetic resonance imaging (MRI) provides an accessible, portable, and low-cost alternative to high-field scanners, expanding diagnostic imaging to point-of-care settings. However, widespread adoption is fundamentally hindered by a severely reduced signal-to-noise ratio (SNR). At low frequencies, radiofrequency (RF) coil conductor losses - rather than tissue sample losses - predominantly govern the system's total noise, making meticulous RF coil optimization critical to recovering image quality. This work presents an open-source, optimized solenoid head coil tailored for the 50 mT open-source scanner (OSII ONE v2.1). The paper validates production reproducibility across three independent international institutions and introduce an open-source connector with integrated digital circuitry for coil identification and DC or logic signals. Comprehensive benchtop measurements, Electromagnetic Interference (EMI) coupling analysis, Specific Absorption Rate (SAR) safety simulations, and phantom and human volunteer imaging confirm the design's efficacy, safety, and reproducibility. The results of the paper, when combined with the material provided in the open-source dedicated repositories, set the basis for a fully reliable and reproducible component for the open-source OSII ONE MRI scanner. In addition, the same optimization strategy and design material can be exploited for designing other RF coils for imaging of other body parts.

physics.med-ph

In-vivo imaging with a low-cost MRI scanner and cloud data processing in low-resource settings

Purpose: To demonstrate in-vivo imaging with a low-cost, low-field MRI scanner built and operated in Africa, and to show how systematic hardware and software improvements can mitigate the main operational limitations encountered in low-resource environments. Methods: A 46 mT Halbach scanner located at the Mbarara University of Science and Technology (Uganda) was upgraded through a complete reorganization of grounding and shielding, installation of new control electronics and open-source user-interface software. Noise performance was quantified using a standardized protocol and in-vivo brain images were acquired with three-dimensional RARE sequences. Distortion correction was implemented using cloud-based reconstructions incorporating magnetic field maps. Results: The revamped system reached noise levels routinely below three times the thermal limit and demonstrated stable operation over multi-day measurements. Three-dimensional T1- and T2-weighted brain images were successfully acquired and distortion-corrected with remote GPU-based reconstructions and near real-time visualization through the user interface. Conclusions: The results show that low-cost MRI systems can achieve clinically relevant image quality when electromagnetic noise and power-grid instabilities are properly addressed. This work highlights the feasibility of sustainable MRI development in low-resource settings and identifies stable power delivery and local capacity building as the key next steps toward clinical translation.

physics.med-ph

Design of a sustainable pre-polarizing magnetic resonance imaging system for infant hydrocephalus

The need for affordable and appropriate medical technologies for developing countries continue to rise as challenges such as inadequate energy supply, limited technical expertise and poor infrastructure persists. Low-field MRI is a technology that can be tailored to meet specific imaging needs within such countries. Its low power requirements and the possibility of operating in minimally shielded or unshielded environments make it especially attractive. Although the technology has been widely demonstrated over several decades, it is yet to be shown that it can be diagnostic and improve patient outcomes in clinical applications. We here demonstrate the robustness of pre-polarizing MRI (PMRI) technology for assembly and deployment in developing countries for the specific application to infant hydrocephalus. Hydrocephalus treatment planning and management requires modest spatial resolution, and only that the brain can be distinguished from fluid - tissue contrast detail within the brain parenchyma is not essential. We constructed an internally shielded PMRI system based on the Lee-Whiting coil system with a 22 cm diameter of spherical volume. In an unshielded room, projection phantom images were acquired at 113 kHz with in-plane resolution of 3 mm x 3 mm, by introducing gradient fields of sufficient magnitude to dominate the 5000ppm inhomogeneity of the readout field. The low cost, straightforward assembly, deployment potential, and maintenance requirements demonstrate the suitability of our PMRI system for developing countries. Further improvement in the image spatial resolution and contrast of low-field MRI will broaden its potential clinical utility beyond hydrocephalus.

physics.med-ph