Searcharxiv⌕ Search

arXiv subjects

Joshua Placidi

Publications and source records attributed to Joshua Placidi.

5 recordsLinked to original sources

Constructing and Validating Memorisation Audits for EHR Foundation Models

Autoregressive electronic health record (EHR) foundation models may disclose training information at inference, yet clinical predictability makes patient-specific memorisation difficult to distinguish from generalisation. We evaluate fixed-window token reconstruction, sensitive-attribute disclosure, and random patient-level canaries in GPT-2-style models trained on MIMIC-IV, across early, best-validation, and final checkpoints. Reconstruction improves with additional context, but training--held-out differences remain small. Trajectory-unique prompts containing limited clinical information produce no excess sensitive disclosure for training patients. In a matched model with random binary patient-level canaries, training-patient label-recovery AUROC increases from 0.512 to 0.549 while held-out recovery remains at chance. An overfit 1,000-patient positive control achieves near-perfect recovery, confirming sensitivity to strong memorisation. These results reveal weak cohort-level memorisation but no reliable patient-level disclosure under the evaluated attacks. They motivate clinically grounded inference-time audits that can detect patient-specific memorisation in existing models without retraining with canaries.

cs.LG↗

Block Diffusion for Longitudinal EHR: Accuracy, Efficiency, and Representation Trade-offs

Autoregressive (AR) models have proved effective for zero-shot prediction from longitudinal electronic health records, but impose strictly sequential generation on trajectories containing temporally clustered and interdependent clinical events. We investigate block-based masked diffusion (BD) as an alternative on MIMIC-IV under matched tokenisation, context length, model capacity, and evaluation conditions. Across block sizes, BD exhibits a clear quality--efficiency trade-off, with small-block configurations retaining much of the predictive performance of AR while enabling substantially faster inference. A representative $B{=}8$ configuration achieves approximately $1.43\times$ faster evaluation. Although generative rollout remains below AR in most settings, frozen linear probes on BD and AR representations achieve near-identical performance across clinical prediction tasks, indicating that BD learns comparably informative clinical representations. Increasing the denoising budget yields diminishing returns, while alternative decoding strategies provide limited gains. Overall, our results show that block diffusion is a viable and computationally attractive approach to longitudinal EHR modelling, with further improvements in iterative decoding offering a promising route toward closing the remaining generative performance gap.

cs.LG↗

Sequence Composition in EHR Foundation Model Pretraining

Autoregressive electronic health record (EHR) foundation models predict the next event token in patient trajectories: sequences of structured medical events. A typical pretraining strategy is to concatenate all trajectories into a global stream and sample token windows from it. This gives patients with longer sequences more training exposure and allows tokens to attend across patient boundaries. We argue that these choices create a misalignment between pretraining and downstream clinical tasks. To explore this, we investigate how the composition of pretraining sequences affects clinical prediction performance. Using the global-stream approach as a baseline, we propose alternative sequence composition methods that control how patient trajectories contribute to pretraining sequences. Across four MIMIC-IV v2.2 tasks, our best method improves macro AUROC, AUPRC, F1, and balanced accuracy, with relative gains of 9.3% in F1 and 2.7% in AUPRC under a fixed training recipe. We find that these gains generalize across four additional evaluation settings, including the INSPIRE and eICU-CRD datasets, with improvements in macro AUROC, AUPRC, and F1 score. Our results show that simply changing how EHR data are presented to the model during pretraining can improve downstream performance, without changing the model or collecting additional data.

cs.LG↗

Pretraining EHR Foundation Models with Patient-Aware Sampling

Autoregressive foundation models for electronic health records (EHRs) typically inherit pretraining methods from language modeling, where patient trajectories are concatenated into a single token stream and windows are sampled from that stream. In EHR data, this choice is consequential: windows may mix multiple patients, and patients with longer records contribute more optimization updates, potentially introducing bias. We propose Patient Sampling, a pretraining sequence-construction method that allows us to control how training signal is distributed across patients. We compare this method to the standard approach, which we refer to as Global Stream. We show that stochastic Patient Sampling with controllable weighting improves performance on real-world EHR data. Across downstream clinical tasks on MIMIC-IV v2.2 and v3.1, Patient Sampling improves Macro AUROC and AUPRC over the Global Stream baseline. These results identify training and validation sequence construction as important and underexplored design choices for autoregressive EHR foundation models.

cs.LG↗

Autoregressive EHR Foundation Models with Multimodal Inputs

Autoregressive foundation models trained on tokenized electronic health records (EHRs) can support zero-shot clinical prediction, yet most operate on structured event codes alone, and do not incorporate multiple modalities in a principled way. We present a framework for conditioning such models on auxiliary clinical modalities, including ECG waveforms, chest X-ray images, and clinical notes, using modality-specific latent compression and gated cross-attention with temporal alignment. We investigate two key design choices: (1) how to compress long per-modality sequences (e.g., ECG time series) before they enter the multi-modal cross-attention. This feature may be essential to reduce compute overheads and may be beneficial for generalization; (2) how the choice of pretrained encoder for each modality impacts downstream performance. Through controlled ablations on MIMIC-IV, we show that the best latent-compression configurations outperforms both uncompressed cross-attention and mean pooling. Encoder choice has a clear within-modality effect, with stronger pretrained encoders consistently outperforming weaker alternatives. We further show that merely adding auxiliary modalities does not guarantee improvement on ICU mortality prediction over an EHR-only baseline. This implies that careful design of the fusion architecture and an appropriate evaluation in the clinical context are required.

cs.LG↗