Searcharxiv⌕ Search

arXiv subjects

Joyita Dutta

Publications and source records attributed to Joyita Dutta.

5 recordsLinked to original sources

EQUIP-RPT: A framework for objective evaluation of quantitative imaging methods in radiopharmaceutical therapies

Quantitative imaging (QI) provides a non-invasive approach for dosimetry and quantitative response assessment in radiopharmaceutical therapies (RPTs). QI methods are being developed for instrumentation, acquisition, reconstruction, and image analysis. However, a key barrier to routine adoption of these methods is that evidence demonstrating reliable performance of QI methods on clinically relevant quantification tasks in RPTs remains limited. Our goal is to outline the Evaluation of Quantitative Imaging Performance in Radiopharmaceutical Therapy (EQUIP-RPT) framework, a structured approach for objective, task-based evaluation of QI methods for RPTs. We outline the EQUIP-RPT framework based on image-science and task-based image-quality evaluation methodology, practical considerations, and recent literature. The framework is organized around four linked design steps: (i) specification of the quantification task, (ii) design of the study population and imaging protocol, (iii) task-specific information extraction, and (iv) selection of figures of merit (FoMs). The EQUIP-RPT framework is presented in the context of four quantification tasks in RPT: activity uptake, absorbed dose, volumetric tumor burden, and lesion-level longitudinal quantifications. The framework distinguishes two paradigms for task-specific information extraction and organizes FoMs according to the performance attributes they characterize. We describe key elements to apply the EQUIP-RPT framework in simulation, physical phantom, and clinical studies. Finally, we show how EQUIP-RPT can be used to generate a quantitative claim based on the evaluation study. The EQUIP-RPT framework is designed to provide a structured approach for objective task-based evaluation of QI methods in RPTs, thereby facilitating clinical translation of these methods.

physics.med-ph↗

Nuclear Medicine AI in Action: The Bethesda Report (AI Summit 2024)

The 2nd SNMMI Artificial Intelligence (AI) Summit, organized by the SNMMI AI Task Force, took place in Bethesda, MD, on February 29 - March 1, 2024. Bringing together various community members and stakeholders, and following up on a prior successful 2022 AI Summit, the summit theme was: AI in Action. Six key topics included (i) an overview of prior and ongoing efforts by the AI task force, (ii) emerging needs and tools for computational nuclear oncology, (iii) new frontiers in large language and generative models, (iv) defining the value proposition for the use of AI in nuclear medicine, (v) open science including efforts for data and model repositories, and (vi) issues of reimbursement and funding. The primary efforts, findings, challenges, and next steps are summarized in this manuscript.

physics.med-ph↗

Issues and Challenges in Applications of Artificial Intelligence to Nuclear Medicine -- The Bethesda Report (AI Summit 2022)

The SNMMI Artificial Intelligence (SNMMI-AI) Summit, organized by the SNMMI AI Task Force, took place in Bethesda, MD on March 21-22, 2022. It brought together various community members and stakeholders from academia, healthcare, industry, patient representatives, and government (NIH, FDA), and considered various key themes to envision and facilitate a bright future for routine, trustworthy use of AI in nuclear medicine. In what follows, essential issues, challenges, controversies and findings emphasized in the meeting are summarized.

physics.med-ph↗

Artificial Intelligence-Based Image Enhancement in PET Imaging: Noise Reduction and Resolution Enhancement

High noise and low spatial resolution are two key confounding factors that limit the qualitative and quantitative accuracy of PET images. AI models for image denoising and deblurring are becoming increasingly popular for post-reconstruction enhancement of PET images. We present here a detailed review of recent efforts for AI-based PET image enhancement with a focus on network architectures, data types, loss functions, and evaluation metrics. We also highlight emerging areas in this field that are quickly gaining popularity, identify barriers to large-scale adoption of AI models for PET image enhancement, and discuss future directions.

eess.IV↗

Super-resolution PET imaging using convolutional neural networks

Positron emission tomography (PET) suffers from severe resolution limitations which limit its quantitative accuracy. In this paper, we present a super-resolution (SR) imaging technique for PET based on convolutional neural networks (CNNs). To facilitate the resolution recovery process, we incorporate high-resolution (HR) anatomical information based on magnetic resonance (MR) imaging. We introduce the spatial location information of the input image patches as additional CNN inputs to accommodate the spatially-variant nature of the blur kernels in PET. We compared the performance of shallow (3-layer) and very deep (20-layer) CNNs with various combinations of the following inputs: low-resolution (LR) PET, radial locations, axial locations, and HR MR. To validate the CNN architectures, we performed both realistic simulation studies using the BrainWeb digital phantom and clinical neuroimaging data analysis. For both simulation and clinical studies, the LR PET images were based on the Siemens HR+ scanner. Two different scenarios were examined in simulation: one where the target HR image is the ground-truth phantom image and another where the target HR image is based on the Siemens HRRT scanner --- a high-resolution dedicated brain PET scanner. The latter scenario was also examined using clinical neuroimaging datasets. A number of factors affected relative performance of the different CNN designs examined, including network depth, target image quality, and the resemblance between the target and anatomical images. In general, however, all CNNs outperformed classical penalized deconvolution techniques by large margins both qualitatively (e.g., edge and contrast recovery) and quantitatively (as indicated by two metrics: peak signal-to-noise-ratio and structural similarity index).

eess.IV↗