Searcharxiv⌕ Search

arXiv subjects

Judy Wawira Gichoya

Publications and source records attributed to Judy Wawira Gichoya.

At least 19 recordsLinked to original sources

Image-Based Breast Implant Detection for Mammography Dataset Curation and Near-Real-Time Deployment: Comparing Foundation Models and Task-Specific Convolutional Models

Purpose: To evaluate the performance-feasibility tradeoffs of foundation models (FMs) and task-specific convolutional neural networks (CNNs) trained from scratch for breast implant classification in 2D mammography, with emphasis on suitability for near real-time clinical deployment. Methods: We evaluated four models: two FMs (RAD-DINO and MammoCLIP) and two CNNs trained from scratch for implant prediction (ResNet18 and our lightweight ResNetLite). Using the Emory Breast Imaging Dataset, 5,000 unilateral screening mammograms were used for training/validation and 1,000 manually reviewed unilateral images were held out for testing. For the FMs, global image embeddings from the pretrained encoder were classified using a support vector machine (SVM). The CNNs were trained end-to-end on 2D mammograms, with ResNetLite optimized via grid search over depth and width to balance accuracy and efficiency. Performance was evaluated using AUROC, sensitivity, specificity, accuracy, embedding visualization, and inference-latency. Results: All models demonstrated strong performance on held-out test data (n = 1,000). MammoCLIP achieved the highest AUROC (0.999) with the quickest training time of 493 seconds. RAD-DINO achieved the highest sensitivity (0.980; accuracy 0.989) but had the slowest inference and training times. ResNet18 and MammoCLIP achieved comparable accuracy (0.985). ResNetLite showed no statistically significant difference from ResNet18 (AUROC 0.993; accuracy 0.976) despite using only 1.4% of ResNet18's parameters, and had the fastest inference time. Conclusion: FMs and task-specific CNN models reliably detect breast implants on 2D mammography. Model selection is best guided by deployment context: MammoCLIP for GPU-equipped hospital settings requiring scalable integration, and lightweight CNNs such as ResNetLite for resource-constrained or edge deployments.

eess.IV↗

Positive-Unlabeled Preference Optimization For Chest X-ray Report Generation

Vision-Language Models (VLMs) for radiology report generation are typically trained on retrospective clinical reports, which suffer from omission noise: clinically present findings are left unreported due to the omission of subtle findings. For example, prior studies show that cardiomegaly may be omitted from ICU chest X-ray reports when the imaging request is focused on monitoring support device placement. As a result, models trained with standard approaches inherit these omissions, learning to under-report findings themselves. We propose PU-DPO, a preference optimization framework to prevent omission noise from corrupting the preference signal. We reformulate the objective under a positive-unlabeled (PU) learning framework, treating absent mentions as unlabeled rather than truly negative. Our framework provides preference supervision using constructed contrastive pairs, generated using edits to model responses, producing variants that explicitly mention or omit a specific finding. Generated responses that mention the finding are naturally preferred in the context of visual evidence. Across semi-synthetic experiments and analyses on real-world chest radiograph benchmarks where adjudicated labels are available, PU-DPO yields consistent gains in detection rates and recovery of hidden positives across multiple pathologies, and is more robust to omission noise than prior approaches.

cs.CV↗

Mammo-FM: Breast-specific foundational model for Integrated Mammographic Diagnosis, Prognosis, and Reporting

Breast cancer is one of the leading causes of death among women worldwide. We introduce Mammo-FM, the first foundation model specifically for mammography, pretrained on the largest and most diverse dataset to date - 140,677 patients (821,326 mammograms) across four U.S. institutions. Mammo-FM provides a unified foundation for core clinical tasks in breast imaging, including cancer diagnosis, pathology localization, structured report generation, and cancer risk prognosis within a single framework. Its alignment between images and text enables both visual and textual interpretability, improving transparency and clinical auditability, which are essential for real-world adoption. We rigorously evaluate Mammo-FM across diagnosis, prognosis, and report-generation tasks in in- and out-of-distribution datasets. Despite operating on native-resolution mammograms and using only one-third of the parameters of state-of-the-art generalist FMs, Mammo-FM consistently outperforms them across multiple public and private benchmarks. These results highlight the efficiency and value of domain-specific foundation models designed around the full spectrum of tasks within a clinical domain and emphasize the importance of rigorous, domain-aligned evaluation.

cs.CV↗

Critical Appraisal of Fairness Metrics in Clinical Predictive AI

Predictive artificial intelligence (AI) offers an opportunity to improve clinical practice and patient outcomes, but risks perpetuating biases if fairness is inadequately addressed. However, the definition of "fairness" remains unclear. We conducted a scoping review to identify and critically appraise fairness metrics for clinical predictive AI. We defined a "fairness metric" as a measure quantifying whether a model discriminates (societally) against individuals or groups defined by sensitive attributes. We searched five databases (2014-2024), screening 820 records, to include 41 studies, and extracted 62 fairness metrics. Metrics were classified by performance-dependency, model output level, and base performance metric, revealing a fragmented landscape with limited clinical validation and overreliance on threshold-dependent measures. Eighteen metrics were explicitly developed for healthcare, including only one clinical utility metric. Our findings highlight conceptual challenges in defining and quantifying fairness and identify gaps in uncertainty quantification, intersectionality, and real-world applicability. Future work should prioritise clinically meaningful metrics.

cs.LG↗

In the Picture: Medical Imaging Datasets, Artifacts, and their Living Review

Datasets play a critical role in medical imaging research, yet issues such as label quality, shortcuts, and metadata are often overlooked. This lack of attention may harm the generalizability of algorithms and, consequently, negatively impact patient outcomes. While existing medical imaging literature reviews mostly focus on machine learning (ML) methods, with only a few focusing on datasets for specific applications, these reviews remain static -- they are published once and not updated thereafter. This fails to account for emerging evidence, such as biases, shortcuts, and additional annotations that other researchers may contribute after the dataset is published. We refer to these newly discovered findings of datasets as research artifacts. To address this gap, we propose a living review that continuously tracks public datasets and their associated research artifacts across multiple medical imaging applications. Our approach includes a framework for the living review to monitor data documentation artifacts, and an SQL database to visualize the citation relationships between research artifact and dataset. Lastly, we discuss key considerations for creating medical imaging datasets, review best practices for data annotation, discuss the significance of shortcuts and demographic diversity, and emphasize the importance of managing datasets throughout their entire lifecycle. Our demo is publicly available at http://inthepicture.itu.dk/.

cs.CV↗

Subgroup Performance of a Commercial Digital Breast Tomosynthesis Model for Breast Cancer Detection

While research has established the potential of AI models for mammography to improve breast cancer screening outcomes, there have not been any detailed subgroup evaluations performed to assess the strengths and weaknesses of commercial models for digital breast tomosynthesis (DBT) imaging. This study presents a granular evaluation of the Lunit INSIGHT DBT model on a large retrospective cohort of 163,449 screening mammography exams from the Emory Breast Imaging Dataset (EMBED). Model performance was evaluated in a binary context with various negative exam types (162,081 exams) compared against screen detected cancers (1,368 exams) as the positive class. The analysis was stratified across demographic, imaging, and pathologic subgroups to identify potential disparities. The model achieved an overall AUC of 0.91 (95% CI: 0.90-0.92) with a precision of 0.08 (95% CI: 0.08-0.08), and a recall of 0.73 (95% CI: 0.71-0.76). Performance was found to be robust across demographics, but cases with non-invasive cancers (AUC: 0.85, 95% CI: 0.83-0.87), calcifications (AUC: 0.80, 95% CI: 0.78-0.82), and dense breast tissue (AUC: 0.90, 95% CI: 0.88-0.91) were associated with significantly lower performance compared to other groups. These results highlight the need for detailed evaluation of model characteristics and vigilance in considering adoption of new tools for clinical deployment.

eess.IV↗

Report of the Medical Image De-Identification (MIDI) Task Group -- Best Practices and Recommendations

This report addresses the technical aspects of de-identification of medical images of human subjects and biospecimens, such that re-identification risk of ethical, moral, and legal concern is sufficiently reduced to allow unrestricted public sharing for any purpose, regardless of the jurisdiction of the source and distribution sites. All medical images, regardless of the mode of acquisition, are considered, though the primary emphasis is on those with accompanying data elements, especially those encoded in formats in which the data elements are embedded, particularly Digital Imaging and Communications in Medicine (DICOM). These images include image-like objects such as Segmentations, Parametric Maps, and Radiotherapy (RT) Dose objects. The scope also includes related non-image objects, such as RT Structure Sets, Plans and Dose Volume Histograms, Structured Reports, and Presentation States. Only de-identification of publicly released data is considered, and alternative approaches to privacy preservation, such as federated learning for artificial intelligence (AI) model development, are out of scope, as are issues of privacy leakage from AI model sharing. Only technical issues of public sharing are addressed.

cs.CR↗

Using large language models to promote health equity

Advances in large language models (LLMs) have driven an explosion of interest about their societal impacts. Much of the discourse around how they will impact social equity has been cautionary or negative, focusing on questions like "how might LLMs be biased and how would we mitigate those biases?" This is a vital discussion: the ways in which AI generally, and LLMs specifically, can entrench biases have been well-documented. But equally vital, and much less discussed, is the more opportunity-focused counterpoint: "what promising applications do LLMs enable that could promote equity?" If LLMs are to enable a more equitable world, it is not enough just to play defense against their biases and failure modes. We must also go on offense, applying them positively to equity-enhancing use cases to increase opportunities for underserved groups and reduce societal discrimination. There are many choices which determine the impact of AI, and a fundamental choice very early in the pipeline is the problems we choose to apply it to. If we focus only later in the pipeline -- making LLMs marginally more fair as they facilitate use cases which intrinsically entrench power -- we will miss an important opportunity to guide them to equitable impacts. Here, we highlight the emerging potential of LLMs to promote equity by presenting four newly possible, promising research directions, while keeping risks and cautionary points in clear view.

cs.CY↗

Multivariate Analysis on Performance Gaps of Artificial Intelligence Models in Screening Mammography

Although deep learning models for abnormality classification can perform well in screening mammography, the demographic, imaging, and clinical characteristics associated with increased risk of model failure remain unclear. This retrospective study uses the Emory BrEast Imaging Dataset(EMBED) containing mammograms from 115931 patients imaged at Emory Healthcare between 2013-2020, with BI-RADS assessment, region of interest coordinates for abnormalities, imaging features, pathologic outcomes, and patient demographics. Multiple deep learning models were trained to distinguish between abnormal tissue patches and randomly selected normal tissue patches from screening mammograms. We assessed model performance by subgroups defined by age, race, pathologic outcome, tissue density, and imaging characteristics and investigated their associations with false negatives (FN) and false positives (FP). We also performed multivariate logistic regression to control for confounding between subgroups. The top-performing model, ResNet152V2, achieved accuracy of 92.6%(95%CI=92.0-93.2%), and AUC 0.975(95%CI=0.972-0.978). Before controlling for confounding, nearly all subgroups showed statistically significant differences in model performance. However, after controlling for confounding, we found lower FN risk associates with Other race(RR=0.828;p=.050), biopsy-proven benign lesions(RR=0.927;p=.011), and mass(RR=0.921;p=.010) or asymmetry(RR=0.854;p=.040); higher FN risk associates with architectural distortion (RR=1.037;p<.001). Higher FP risk associates to BI-RADS density C(RR=1.891;p<.001) and D(RR=2.486;p<.001). Our results demonstrate subgroup analysis is important in mammogram classifier performance evaluation, and controlling for confounding between subgroups elucidates the true associations between variables and model failure. These results can help guide developing future breast cancer detection models.

eess.IV↗

Augmenting Vision Language Pretraining by Learning Codebook with Visual Semantics

Language modality within the vision language pretraining framework is innately discretized, endowing each word in the language vocabulary a semantic meaning. In contrast, visual modality is inherently continuous and high-dimensional, which potentially prohibits the alignment as well as fusion between vision and language modalities. We therefore propose to "discretize" the visual representation by joint learning a codebook that imbues each visual token a semantic. We then utilize these discretized visual semantics as self-supervised ground-truths for building our Masked Image Modeling objective, a counterpart of Masked Language Modeling which proves successful for language models. To optimize the codebook, we extend the formulation of VQ-VAE which gives a theoretic guarantee. Experiments validate the effectiveness of our approach across common vision-language benchmarks.

cs.CV↗

Few-Shot Transfer Learning to improve Chest X-Ray pathology detection using limited triplets

Deep learning approaches applied to medical imaging have reached near-human or better-than-human performance on many diagnostic tasks. For instance, the CheXpert competition on detecting pathologies in chest x-rays has shown excellent multi-class classification performance. However, training and validating deep learning models require extensive collections of images and still produce false inferences, as identified by a human-in-the-loop. In this paper, we introduce a practical approach to improve the predictions of a pre-trained model through Few-Shot Learning (FSL). After training and validating a model, a small number of false inference images are collected to retrain the model using \textbf{\textit{Image Triplets}} - a false positive or false negative, a true positive, and a true negative. The retrained FSL model produces considerable gains in performance with only a few epochs and few images. In addition, FSL opens rapid retraining opportunities for human-in-the-loop systems, where a radiologist can relabel false inferences, and the model can be quickly retrained. We compare our retrained model performance with existing FSL approaches in medical imaging that train and evaluate models at once.

eess.IV↗

OSCARS: An Outlier-Sensitive Content-Based Radiography Retrieval System

Improving the retrieval relevance on noisy datasets is an emerging need for the curation of a large-scale clean dataset in the medical domain. While existing methods can be applied for class-wise retrieval (aka. inter-class), they cannot distinguish the granularity of likeness within the same class (aka. intra-class). The problem is exacerbated on medical external datasets, where noisy samples of the same class are treated equally during training. Our goal is to identify both intra/inter-class similarities for fine-grained retrieval. To achieve this, we propose an Outlier-Sensitive Content-based rAdiologhy Retrieval System (OSCARS), consisting of two steps. First, we train an outlier detector on a clean internal dataset in an unsupervised manner. Then we use the trained detector to generate the anomaly scores on the external dataset, whose distribution will be used to bin intra-class variations. Second, we propose a quadruplet (a, p, nintra, ninter) sampling strategy, where intra-class negatives nintra are sampled from bins of the same class other than the bin anchor a belongs to, while niner are randomly sampled from inter-classes. We suggest a weighted metric learning objective to balance the intra and inter-class feature learning. We experimented on two representative public radiography datasets. Experiments show the effectiveness of our approach. The training and evaluation code can be found in https://github.com/XiaoyuanGuo/oscars.

cs.CV↗

Best Practices and Scoring System on Reviewing A.I. based Medical Imaging Papers: Part 1 Classification

With the recent advances in A.I. methodologies and their application to medical imaging, there has been an explosion of related research programs utilizing these techniques to produce state-of-the-art classification performance. Ultimately, these research programs culminate in submission of their work for consideration in peer reviewed journals. To date, the criteria for acceptance vs. rejection is often subjective; however, reproducible science requires reproducible review. The Machine Learning Education Sub-Committee of SIIM has identified a knowledge gap and a serious need to establish guidelines for reviewing these studies. Although there have been several recent papers with this goal, this present work is written from the machine learning practitioners standpoint. In this series, the committee will address the best practices to be followed in an A.I.-based study and present the required sections in terms of examples and discussion of what should be included to make the studies cohesive, reproducible, accurate, and self-contained. This first entry in the series focuses on the task of image classification. Elements such as dataset curation, data pre-processing steps, defining an appropriate reference standard, data partitioning, model architecture and training are discussed. The sections are presented as they would be detailed in a typical manuscript, with content describing the necessary information that should be included to make sure the study is of sufficient quality to be considered for publication. The goal of this series is to provide resources to not only help improve the review process for A.I.-based medical imaging papers, but to facilitate a standard for the information that is presented within all components of the research study. We hope to provide quantitative metrics in what otherwise may be a qualitative review process.

eess.IV↗

CVAD: A generic medical anomaly detector based on Cascade VAE

Detecting out-of-distribution (OOD) samples in medical imaging plays an important role for downstream medical diagnosis. However, existing OOD detectors are demonstrated on natural images composed of inter-classes and have difficulty generalizing to medical images. The key issue is the granularity of OOD data in the medical domain, where intra-class OOD samples are predominant. We focus on the generalizability of OOD detection for medical images and propose a self-supervised Cascade Variational autoencoder-based Anomaly Detector (CVAD). We use a variational autoencoders' cascade architecture, which combines latent representation at multiple scales, before being fed to a discriminator to distinguish the OOD data from the in-distribution (ID) data. Finally, both the reconstruction error and the OOD probability predicted by the binary discriminator are used to determine the anomalies. We compare the performance with the state-of-the-art deep learning models to demonstrate our model's efficacy on various open-access medical imaging datasets for both intra- and inter-class OOD. Further extensive results on datasets including common natural datasets show our model's effectiveness and generalizability. The code is available at https://github.com/XiaoyuanGuo/CVAD.

eess.IV↗

Margin-Aware Intra-Class Novelty Identification for Medical Images

Traditional anomaly detection methods focus on detecting inter-class variations while medical image novelty identification is inherently an intra-class detection problem. For example, a machine learning model trained with normal chest X-ray and common lung abnormalities, is expected to discover and flag idiopathic pulmonary fibrosis which a rare lung disease and unseen by the model during training. The nuances from intra-class variations and lack of relevant training data in medical image analysis pose great challenges for existing anomaly detection methods. To tackle the challenges, we propose a hybrid model - Transformation-based Embedding learning for Novelty Detection (TEND) which without any out-of-distribution training data, performs novelty identification by combining both autoencoder-based and classifier-based method. With a pre-trained autoencoder as image feature extractor, TEND learns to discriminate the feature embeddings of in-distribution data from the transformed counterparts as fake out-of-distribution inputs. To enhance the separation, a distance objective is optimized to enforce a margin between the two classes. Extensive experimental results on both natural image datasets and medical image datasets are presented and our method out-performs state-of-the-art approaches.

cs.CV↗

MedShift: identifying shift data for medical dataset curation

To curate a high-quality dataset, identifying data variance between the internal and external sources is a fundamental and crucial step. However, methods to detect shift or variance in data have not been significantly researched. Challenges to this are the lack of effective approaches to learn dense representation of a dataset and difficulties of sharing private data across medical institutions. To overcome the problems, we propose a unified pipeline called MedShift to detect the top-level shift samples and thus facilitate the medical curation. Given an internal dataset A as the base source, we first train anomaly detectors for each class of dataset A to learn internal distributions in an unsupervised way. Second, without exchanging data across sources, we run the trained anomaly detectors on an external dataset B for each class. The data samples with high anomaly scores are identified as shift data. To quantify the shiftness of the external dataset, we cluster B's data into groups class-wise based on the obtained scores. We then train a multi-class classifier on A and measure the shiftness with the classifier's performance variance on B by gradually dropping the group with the largest anomaly score for each class. Additionally, we adapt a dataset quality metric to help inspect the distribution differences for multiple medical sources. We verify the efficacy of MedShift with musculoskeletal radiographs (MURA) and chest X-rays datasets from more than one external source. Experiments show our proposed shift data detection pipeline can be beneficial for medical centers to curate high-quality datasets more efficiently. An interface introduction video to visualize our results is available at https://youtu.be/V3BF0P1sxQE.

eess.IV↗

A Prospective Observational Study to Investigate Performance of a Chest X-ray Artificial Intelligence Diagnostic Support Tool Across 12 U.S. Hospitals

Importance: An artificial intelligence (AI)-based model to predict COVID-19 likelihood from chest x-ray (CXR) findings can serve as an important adjunct to accelerate immediate clinical decision making and improve clinical decision making. Despite significant efforts, many limitations and biases exist in previously developed AI diagnostic models for COVID-19. Utilizing a large set of local and international CXR images, we developed an AI model with high performance on temporal and external validation. Conclusions and Relevance: AI-based diagnostic tools may serve as an adjunct, but not replacement, for clinical decision support of COVID-19 diagnosis, which largely hinges on exposure history, signs, and symptoms. While AI-based tools have not yet reached full diagnostic potential in COVID-19, they may still offer valuable information to clinicians taken into consideration along with clinical signs and symptoms.

eess.IV↗