SearcharxivSearch

arXiv subjects

Juerg Schwitter

Publications and source records attributed to Juerg Schwitter.

2 recordsLinked to original sources

End-to-End 4D Heart Mesh Recovery Across Full-Stack and Sparse Cardiac MRI

Reconstructing cardiac motion from CMR sequences is critical for diagnosis, prognosis, and intervention. Existing methods rely on complete CMR stacks to infer full heart motion, limiting their applicability during intervention when only sparse observations are available. We present TetHeart, the first end-to-end framework for unified 4D heart mesh recovery from both offline full-stack and intra-procedural sparse-slice observations. Our method leverages deformable tetrahedra to capture shape and motion in a coherent space shared across cardiac structures. Before a procedure, it initializes detailed, patient-specific heart meshes from high-quality full stacks, which can then be updated using whatever slices can be obtained in real-time, down to a single one during the procedure. TetHeart incorporates several key innovations: (i) an attentive slice-adaptive 2D-3D feature assembly mechanism that integrates information from arbitrary numbers of slices at any position; (ii) a distillation strategy to ensure accurate reconstruction under extreme sparsity; and (iii) a weakly supervised motion learning scheme requiring annotations only at keyframes, such as the end-diastolic and end-systolic phases. Trained and validated on three large public datasets and evaluated zero-shot on additional private interventional and public datasets without retraining, TetHeart achieves state-of-the-art accuracy and strong generalization in both pre- and intra-procedural settings. Code and dataset is available at https://github.com/Scalsol/TetHeart.

cs.CV

Motion Compensated Whole-Heart Coronary Magnetic Resonance Angiography using Focused Navigation (fNAV)

Background: RSN whole-heart CMRA is a technique that estimates and corrects for respiratory motion. However, RSN has been limited to a 1D rigid correction which is often insufficient for patients with complex respiratory patterns. The goal of this work is therefore to improve the robustness and quality of 3D radial CMRA by incorporating both 3D motion information and nonrigid intra-acquisition correction of the data into a framework called focused navigation (fNAV). Methods: We applied fNAV to 500 data sets from a numerical simulation, 22 healthy volunteers, and 549 cardiac patients. We compared fNAV to RSN and respiratory resolved XD-GRASP reconstructions of the same data and recorded reconstruction times. Motion accuracy was measured as the correlation between fNAV and ground truth for simulations, and fNAV and image registration for in vivo data. Vessel sharpness was measured using Soap-Bubble. Finally, image quality analysis was performed by a blinded expert reviewer who chose the best image for each data set. Results The reconstruction time for fNAV images was significantly higher than RSN (6.1 +/- 2.1 minutes vs 1.4 +/- 0.3, minutes, p<0.025) but significantly lower than XD-GRASP (25.6 +/- 7.1, minutes, p<0.025). There is high correlation between the fNAV, and reference displacement estimates across all data sets (0.73 +/- 0.29). For all data, fNAV lead to significantly sharper vessels than all other reconstructions (p < 0.01). Finally, a blinded reviewer chose fNAV as the best image in 239 out of 571 cases (p = 10-5). Conclusion: fNAV is a promising technique for improving free-breathing 3D radial whole-heart CMRA. This novel approach to respiratory self-navigation can derive 3D nonrigid motion estimations from an acquired 1D signal yielding statistically significant improvement in image sharpness relative to 1D translational correction as well as XD-GRASP reconstructions.

eess.IV