Julia Pfitzer

Publications and source records attributed to Julia Pfitzer.

3 recordsLinked to original sources

A Reference System for Open Source Portable Low-Field MRI

Despite its renewed attention, the pathway to point-of-care portable low-field MRI systems remains challenging, limiting adoption across research groups. Incomplete documentation limits reproducibility, causing redesign and complicating cross-system comparison. Moreover, non-standardized testing and characterization complicates ethical approval for clinical studies. We present an open-source reference system for portable low-field MRI designed to support replication, reproducibility, benchmarking, and quantitative comparison. The system is fully open source, based on a ~50 mT permanent magnet, and integrated with a cloud-native acquisition platform. Pulseq-based calibration, characterization, and imaging sequences assessed noise level, eddy currents, image-based SNR, and geometric accuracy. Quantitative T1, T2, and B0 mapping sequences were developed and evaluated against reference values. Initial results from independent replications at two sites were compared. The system reached a noise level of 1.4 relative to the thermal noise floor and short eddy-current decay constants of 27-32 us across all gradient channels. Geometric deviations were below 2 mm over the field of view. Image-based SNR were consistent between the independent replications. Measured T1 values closely matched specified values, with an average absolute error of 3.1(1.8)%, while T2 values were overestimated by 10.4(5.8)%. Simulations showed only marginal errors for both quantities, suggesting experimental error sources for T2 mapping. The reference system combines openly documented hardware, software, calibration procedures, phantoms, quantitative MRI, and simulation tools in a reproducible ecosystem, aiming to support cross-site comparability, reproducible research, and collaborative development of future portable low-field MRI technologies.

physics.med-ph

Birth of the Coil: another Milestone towards a fully reproducible low-field MRI scanner for head-imaging

Low-field magnetic resonance imaging (MRI) provides an accessible, portable, and low-cost alternative to high-field scanners, expanding diagnostic imaging to point-of-care settings. However, widespread adoption is fundamentally hindered by a severely reduced signal-to-noise ratio (SNR). At low frequencies, radiofrequency (RF) coil conductor losses - rather than tissue sample losses - predominantly govern the system's total noise, making meticulous RF coil optimization critical to recovering image quality. This work presents an open-source, optimized solenoid head coil tailored for the 50 mT open-source scanner (OSII ONE v2.1). The paper validates production reproducibility across three independent international institutions and introduce an open-source connector with integrated digital circuitry for coil identification and DC or logic signals. Comprehensive benchtop measurements, Electromagnetic Interference (EMI) coupling analysis, Specific Absorption Rate (SAR) safety simulations, and phantom and human volunteer imaging confirm the design's efficacy, safety, and reproducibility. The results of the paper, when combined with the material provided in the open-source dedicated repositories, set the basis for a fully reliable and reproducible component for the open-source OSII ONE MRI scanner. In addition, the same optimization strategy and design material can be exploited for designing other RF coils for imaging of other body parts.

physics.med-ph

FENCE: Flexible Electric Noise reduCtion Endo-shield for the Suppression of Electromagnetic Interference in Low-Field MRI

Electromagnetic interference (EMI) is a significant challenge for low-field MRI systems operating without conventional Faraday-shielded rooms. Traditional EMI mitigation approaches include external shields, subject grounding via electrodes, or active noise cancellation requiring synchronized receive channels. These methods either limit portability, introduce patient discomfort, or demand advanced hardware. In this work, we start from the hypothesis that EMI primarily couples capacitively from the body to the RF coil. We investigated two methods of blocking capacitive coupling while preserving inductive MRI signal detection: First, we employed capacitive segmentation of the RF coil and studied its effect on EMI coupling. Second, we present FENCE (Flexible Electromagnetic Noise reduCtion Endo-shield), a novel approach blocking capacitive coupling using flexible PCB shields placed inside the RF coil. FENCE can be retrofitted to existing RF coils. Finite element (FE) simulations were used to estimate the expected shielding performance and the impact on RF coil losses prior to practical implementation. Testing in various realistic scenarios then demonstrated that the combination of FENCE with segmented solenoid coils is effective against both environmental noise sources and controlled EMI. In phantom experiments, FENCE significantly improved imaging performance and reduced EMI levels to near-baseline levels with 9% reduction in coil quality factor (Q factor), showing good agreement with the predictions from the FE simulations. In-vivo head imaging confirmed these results across diverse electromagnetic environments significantly improving imaging performance while showing an ~18% decrease in Q factor. FENCE provides a simple method for EMI mitigation in low-field MRI, enhancing image quality while maintaining system portability and accessibility.

physics.med-ph