Protection-Oriented Assessment of Machine Learning-Based Fault Detection in Power Systems

Machine learning (ML)-based fault detectors are increasingly proposed for power system protection, yet aggregate metrics can obscure the consequences of false and missed trips. We present a protection-oriented assessment of three ML detectors and a sequence-current reference on PROTECT-90, comprising 9,022 simulated fault episodes on a 90 kV double-circuit line. The assessment combines five window conditions, causal window-end labelling, episode-grouped cross-validation, and operating-point selection under a fixed security budget. It reports security, dependability, detection timing, decision margins, and episode-level nuisance assertions. Gradient-boosted trees, a convolutional neural network, and logistic regression achieve AUC-ROC values above 0.999, yet at a security budget of $10^{-3}$ their developed-fault missed-trip rates range from 0.007% to 1.99%. Post-clearing false-trip rates of approximately 0.12-0.16% per window coexist with nuisance assertions in 11.3-19.1% of episodes. Among the analysed physical descriptors, missed trips are most consistently associated with higher fault resistance within the sampled range. An analytical current proxy suggests a fault-current gradient only partly reproduced by waveform-derived current (rank correlation 0.62). No single topology state or faulted phase consistently dominates within the sampled domain. Because PROTECT-90 contains fault episodes only, security is assessed on pre-fault and post-clearing windows rather than independent non-fault disturbances.

cs.LG↗

Distributed Predictive Flocking for a Swarm of Miniature Vibration-Driven Robots in a Confined Arena

Coordinating many miniature robots in a confined arena, with no leader, central planner, or global map, is a core challenge for swarm robotics. As the swarm grows denser, collision avoidance becomes the limiting factor, and the number of safely coexisting robots depends on the formulation of the inter-robot safety constraint. We present a distributed predictive flocking controller in which each robot solves its own nonlinear model predictive control (NMPC) problem, optimizing swarm cohesion and alignment costs, inter-robot and obstacle safety, and a task objective, while exchanging only predicted trajectories with local neighbors. Within this generalized controller architecture, solved in real time, we compare six barrier and control-barrier-function (CBF) safety formulations on a digital twin of an open-source vibration-driven bristlebot in a $0.64\,\mathrm{m^2}$ arena. A look-ahead discrete-time CBF performs best overall, with the fewest collisions and the widest inter-robot margins across nearly every swarm size tested. We deploy it on phototaxis, phototactic orbiting, and cohesion without a stimulus tasks, using swarm sizes starting from ten robots and up to the geometric packing limit. The swarm holds well: collisions stay low in small swarms, rising steeply as the packing limit approaches, while coordination and cohesion degrade gently rather than collapsing. The swarm is found not to trade safety for order, keeping both across the confined arena, with local alignment high at every swarm size.

cs.RO↗

Parameter-Efficient Adaptation of Time Series Foundation Models for Electrical Load Forecasting

Accurate electrical load forecasting supports power-system operation across countries, regions, cities, and buildings, but repeated development of target-specific models is costly. Time series foundation models (TSFMs) provide reusable pretrained backbones, although multi-domain pretraining may not fully capture load-specific characteristics. This paper compares pretrained inference, full fine-tuning, and low-rank adaptation (LoRA) in terms of forecasting accuracy and adaptation efficiency across four electrical load aggregation levels. MOIRAI 1.0 Large serves as the primary backbone, while Chronos-2 assesses whether the findings transfer across model families. The evaluation covers both in-distribution (ID) and out-of-distribution (OOD) settings and examines whether compact adaptation provides consistent gains over strong pretrained checkpoints. Pretrained foundation models outperform the implemented seasonal naive and XGBoost baselines across the evaluated aggregation levels. On MOIRAI Large, rank-16 LoRA reduces normalized mean absolute error (NMAE) by 7.5% on average while updating 3.146 million parameters, about 1% of the model, and retains most of the improvement from full fine-tuning. Chronos-2 achieves lower pretrained NMAE than MOIRAI, while its relative adaptation gains remain smaller overall. OOD results show that adaptation benefits vary by target, with the clearest gains for the local-area series and several buildings. Overall, LoRA provides a favorable accuracy-efficiency trade-off when adaptation yields a meaningful gain over a strong pretrained checkpoint.

cs.LG↗

Characterizing Cross-Relay Generalization Failure in Machine Learning-Based Power System Protection

Machine learning-based fault detectors are often evaluated at the relay locations used for training, although local voltage and current measurements vary across power networks. This work investigates cross-relay generalization for binary detection of faults anywhere in the network using local measurements, rather than line-selective tripping. Using 50 ms windows from a simulated 110 kV transmission network, we evaluate a multilayer perceptron across all 64 source target combinations of eight relays and five random seeds. A shared simulation-level split and source-only threshold selection provide a controlled held-out evaluation without target-specific calibration. Despite nearly unchanged mean F1-scores (0.730 within-relay versus 0.734 cross-relay), the mean false-positive rate (FPR) increases from 0.088 to 0.341, while the mean false-negative rate decreases from 0.399 to 0.318. The change is strongly directional: models trained at Bus 2 relays yield a mean FPR of 0.670 at Bus 1 and Bus 3 relays, compared with 0.096 for cross-relay transfers within the same bus group. Linear probing indicates that learned representations retain coarse bus-group information, while exploratory class-conditional latent distribution analysis shows no consistent monotonic association with transfer errors. These findings demonstrate that aggregate metrics can conceal location-structured changes in false-alarm behavior, highlighting the importance of evaluating error types separately when assessing cross-relay generalization.

cs.LG↗

Physics-Informed but Not Physics-Consistent: Error Geometry and Subspace Projection for Neural AC Power Flow

Recent neural power-flow solvers, including emerging foundation models, achieve accurate voltage predictions, yet such accuracy does not necessarily imply physically consistent solutions. Even small complex voltage errors can yield large AC power-balance residuals. We study this accuracy-consistency gap across PIGNN-GC, GridSFM, gridfm-graphkit, and LUMINA on realistic 2224-bus Great Britain network (GBnetwork) scenarios, with cross-grid evaluation of GridSFM over 31 systems. Using a singular value decomposition (SVD) basis fitted to training AC power-flow solutions, we find that neural prediction errors contain substantial components outside the dominant solution subspace. To address this mismatch, calibrated solution-subspace projection (CSP) suppresses off-subspace prediction components after train-only bias calibration, reducing Mean PB by 67.0%, 37.8%, 40.5%, and 68.9% for PIGNN-GC, GridSFM, gridfm-graphkit, and LUMINA, respectively, relative to calibrated predictions, while improving voltage-magnitude accuracy in all four models. These results identify output-error geometry as an important factor in physics-consistent neural AC power flow. Code: https://github.com/Kimchangheon/neural-acpf-error-geometry

cs.LG↗

Physics-informed GNN for medium-high voltage AC power flow with edge-aware attention and line search correction operator

Physics-informed graph neural networks (PIGNNs) have emerged as fast AC power-flow solvers that can replace the classic NewtonRaphson (NR) solvers, especially when thousands of scenarios must be evaluated. However, current PIGNNs still need accuracy improvements at parity speed; in particular, the soft constraint on the physics loss is inoperative at inference, which can deter operational adoption. We address this with PIGNN-Attn-LS, combining an edge-aware attention mechanism that explicitly encodes line physics via per-edge biases to form a fully differentiable knownoperator layer inside the computation graph, with a backtracking line-search-based globalized correction operator that restores an operative decrease criterion at inference. Training and testing use a realistic High-/Medium-Voltage scenario generator, with NR used only to construct reference states. On held-out HV cases consisting of 4-32-bus grids, PIGNN-Attn-LS achieves a test RMSE of 0.00033 p.u. in voltage and 0.08 deg in angle, outperforming the PIGNN-MLP baseline by 99.5% and 87.1%, respectively. With streaming micro-batches, it delivers 2-5x faster batched inference than NR on 4-1024-bus grids.

cs.LG↗

EvEMTBench: An Open Benchmark for Machine Learning in Power System Protection

Studies of machine-learning-based power system protection are difficult to compare because task definitions, measurement access, data partitions, metrics, and generalization conditions often differ. EvEMTBench addresses this gap with an open, executable, and versioned benchmark that fixes these evaluation choices while leaving model design open. Across four grids spanning 20-345 kV, it defines 12 protection and event-analysis functions instantiated as 24 scored tasks and supports structured evaluation across observability conditions, predefined distribution shifts, and zero-shot and fine-tuned cross-grid transfer. Committed partitions, leakage controls, and reproducible reporting provide a common basis for comparing future methods. A reference evaluation spanning trivial, conventional, feature-based, and deep-learning baselines shows that wider observability is not uniformly beneficial, shifted conditions can reveal failures not apparent in-distribution, and cross-grid transfer is substantially stronger for fault detection than for fault localization. Protection-relevant diagnostics identify failure modes not apparent from primary metrics alone. EvEMTBench therefore makes generalization in machine-learning-based protection an explicit and reproducible evaluation problem.

eess.SY↗

Offline Reinforcement Learning for Distribution-Grid Protection

Data-driven protection may complement conventional relays in distribution grids whose operating conditions vary with distributed generation, switching events, and changing short-circuit levels. We study line-selective tripping from static trajectories of a realistically simulated CIGRE medium-voltage network using offline reinforcement learning. A convolutional Q-network receives causal voltage-current phasor and apparent-impedance features, optionally together with raw waveforms, and is trained with conservative Q-learning (CQL). A controlled sensitivity study evaluates two observation windows, reward variants, and three CQL weights under a common split and training protocol; one exploratory post-hoc run additionally increases the discount factor from $γ$=0.95 to 0.99. On 225 held-out episodes, the best per-timestep result is obtained with combined input and CQL weight $α$=0.9, reaching precision 0.9993, recall 0.9496, and F1-score 0.9738. Because dense per-timestep scores do not encode the terminal semantics of relay operation, we also evaluate the first non-wait action in each episode. The default combined-input agent selects the correct line-trip action first in 98.13% of 214 fault episodes, but trips in 72.73% of the 11 non-fault episodes. In the post-hoc run, the corresponding rates are 98.60% and 54.55%, respectively. The results show that dense predictive performance and terminal protection behavior can lead to different model rankings. Offline CQL therefore demonstrates strong faulted-line selection on the simulated fault episodes, while the static trajectories, small non-fault set, and single-seed post-hoc design preclude conclusions about practical relay security or deployment readiness.

eess.SY↗

Peak-Aware Short-Term Load Forecasting Across Distribution Grid Aggregation Levels

For distribution system operators, short-term load forecasting (STLF) supports congestion management, voltage control, and asset protection. Most existing approaches focus on overall accuracy across all time steps and neglect performance during high-demand (HD) periods, where larger forecast errors can increase the risk of congestion and voltage violations. In this paper, we study peak-aware STLF across three operator-relevant distribution grid aggregation levels, area codes (AC), secondary substations (SUB), and low-voltage (LV) feeders, using open datasets from the United Kingdom and Switzerland. We compare statistical baselines, machine learning models (LightGBM and XGBoost), and recent time-series foundation models (Chronos Bolt and Chronos-2) under a peak-aware evaluation framework that reports both overall and HD forecasting performance using NMAE and MAPE. The results show that Chronos-2 achieves the best HD performance across all aggregation levels, with HD-NMAE and HD-MAPE of 0.039 and 4.53% at AC, 0.080 and 9.45% at SUB, and 0.138 and 16.14% at LV, while Chronos-Bolt consistently ranks second best. Compared with the gradient boosted ML models, Chronos-2 reduces mean HD-NMAE by about 20-51% across levels while remaining best or near-best on the overall metrics. A quantile analysis of the probabilistic Chronos outputs further identifies aggregation-specific operating points, and runtime measurements indicate that foundation model inference is fast enough for practical deployment. Overall, the findings highlight peak-aware evaluation and aggregation specific quantile selection as a practical pathway toward more operationally relevant STLF in distribution networks.

cs.LG↗

A Systematic Evaluation of Machine Learning Methods for Fault Detection and Line Identification in Electrical Power Grids

The integration of renewable energy sources into the electrical grid introduces complex challenges in fault detection and coordination of grid recovery mechanisms. Traditional relay protection systems, which operate based on static rules and predefined thresholds, are inadequate for addressing these challenges, particularly in detecting and isolating faults such as short circuits. Consequently, the conventional methodologies applied to electrical network protection frequently fail to achieve optimal performance in fault detection, especially in terms of adherence to safety standards and the selective limitation of damage. Recent research indicates that machine learning (ML)-based approaches can effectively tackle these issues; however, variations in grid configurations and analysis windows have impeded consistent comparative assessments. In this study, we assess the efficacy of various ML models in detecting electrical faults and pinpointing defective transmission lines within a 10 ms measurement interval - a critical time-frame for real-time operational viability, for the first time. The most effective model attained an F1 score of 0.991 +/- 0.018 and demonstrated a processing time of 0.342ms +/- 0.509ms.

cs.LG↗

Unsupervised Clustering for Fault Analysis in High-Voltage Power Systems Using Voltage and Current Signals

The widespread use of sensors in modern power grids has led to the accumulation of large amounts of voltage and current waveform data, especially during fault events. However, the lack of labeled datasets poses a significant challenge for fault classification and analysis. This paper explores the application of unsupervised clustering techniques for fault diagnosis in high-voltage power systems. A dataset provided by the Réseau de Transport d'Électricité (RTE) is analyzed, with frequency domain features extracted using the Fast Fourier Transform (FFT). The K-Means algorithm is then applied to identify underlying patterns in the data, enabling automated fault categorization without the need for labeled training samples. The resulting clusters are evaluated in collaboration with power system experts to assess their alignment with real-world fault characteristics. The results demonstrate the potential of unsupervised learning for scalable and data-driven fault analysis by structuring large unlabeled waveform datasets and supporting targeted expert review.

cs.LG↗

A simulation based dataset of faults and events for machine learning in power systems

The integration of inverter-based renewable energy sources into electric grids challenges conventional power system protection. Machine learning-based solutions can address these challenges by utilizing available data in modern smart grids. However, the lack of open datasets prevents reproducibility and fair comparisons between different approaches and their results, which hinders further progress. Therefore, this paper presents EvEMTBench, a synthetic dataset of faults and events generated using electromagnetic transient simulations. The physical plausibility of the power system simulation is ensured by validating the simulation parameters against established literature and providing comprehensive documentation of the simulation procedure. The dataset is designed for training, fine-tuning, and benchmarking machine learning models by providing synchronized point-on-wave voltage and current measurements at 9600 Hz across a diverse set of topologies and voltage levels. The inclusion of a wide range of fault and operating events allows the utilization of EvEMTBench for different tasks like incipient fault detection, fault localization, or event detection.

eess.SY↗

A Standardized Framework for Machine Learning in Power System Protection

Studies of machine-learning-based power-system protection increasingly report near-perfect scores, yet the meaning of those scores depends strongly on the evaluation setting. Protection task, physical scope, measurements, timing, targets, preprocessing, and validation often vary jointly and remain incompletely specified. This paper proposes a standardization-oriented framework that treats evaluation design as part of the scientific contribution. It defines seven required study dimensions: protection objective, physical scope, observability, timing and decision windows, targets and sample validity, validation protocol, and evaluation outputs. The framework is instantiated in a bounded case study on the public PROTECT-90 electromagnetic-transient benchmark, comprising 9022 simulated episodes from a 90 kV double-line topology, for onset-conditioned fault classification and localization. Under centralized sensing, simulation-metadata-aligned 20 ms windows, and episode-grouped validation, a multi-layer perceptron (MLP) achieved a five-fold mean macro-averaged F1 score of 0.991 +/- 0.001 for classification and a localization mean absolute error of 10.20 +/- 0.25% of line length (mean +/- std across episode-grouped folds). Extending the decision horizon to 50 ms preserved this task-dependent performance asymmetry, while reduced observability approximately doubled the MLP localization error but had little effect on classification. A synchronized two-ended conventional locator outperformed the learning locators under its richer clean information set, and measurement degradation showed that clean predictive performance did not determine robustness. The framework turns evaluation assumptions into explicit, reproducible evidence and provides a basis for more comparable, auditable evaluation and future certification-oriented assessment of machine-learning protection functions.

cs.LG↗

PROTECT-90: A Fault Dataset for Power System Protection

The increasing interest in data-driven methods for power system protection is accompanied by a lack of standardized, publicly available high-voltage waveform datasets that enable transparent and reproducible evaluation. To address this gap, this paper introduces the PROTECT-90 dataset, an open electromagnetic transient (EMT)-simulated reference benchmark for high-voltage fault studies with consistent digital-fault-recorder-like measurements, publicly released with this work. The dataset comprises 9,022 physically consistent short-circuit simulation episodes generated on a standardized 90 kV double-line topology with systematically documented domain randomization of grid operating points, line parameters, and fault conditions. For each episode, synchronized three-phase voltage and current waveforms are recorded at eight measurement locations and released together with structured, machine-readable metadata describing fault type, fault location, inception time, and operating conditions. All modeling assumptions, parameter ranges, and data-generation procedures are explicitly documented to ensure transparency and cross-study comparability. By combining physically grounded EMT simulation, balanced scenario coverage, and open accessibility, PROTECT-90 establishes a standardized foundation for reproducible benchmarking of protection-oriented signal processing and learning-based methods.

eess.SP↗

Fault Inception Detection in Real-World Disturbance Data for Power System Protection

Large collections of real-world disturbance recordings are increasingly available in transmission networks, but their value for power system protection and automated disturbance analysis is limited by the absence of precise event-onset annotations. In practice, field-recorded voltage and current waveforms contain switching operations, transformer energization, resonance, saturation, and other non-ideal effects that can obscure or mimic genuine fault signatures, making reliable fault inception detection difficult. This paper presents an training-free framework for fault inception detection in real-world transmission disturbance data. The method combines protection-domain indicators, robust median/MAD-based normalization, a low-latency transient path, and persistence-aware fusion and veto logic to distinguish fault-consistent disturbances from non-fault transients. We apply the framework to 12053 transmission-level recordings from the publicly available RTE database and further assess detector performance on a manually reviewed subset of 300 events. On the reviewed subset, the detector achieves 96.6% recall, 79.2% precision, and a median timing error of 4.2ms for matched detections. These results indicate that the proposed approach can support protection-oriented disturbance screening, relay and post-event analysis, and the creation of timestamp annotations for downstream data-driven monitoring tasks.

eess.SP↗

Controlled Comparison of Machine Learning Models for Fault Classification and Localization in Power System Protection

The increasing complexity of modern power systems, driven by the integration of inverter-based and distributed energy resources, challenges the reliability of conventional protection schemes and motivates the use of machine learning for protection tasks. However, published results are often difficult to compare because datasets, sensing assumptions, and decision horizons vary across studies. This paper presents a controlled comparison of machine learning models for fault classification (FC) and fault localization (FL) under identical sensing, timing, and validation conditions on a common electromagnetic transient dataset, using decision windows of 10-50 ms to reflect protection-relevant time scales. For FC, the best-performing nonlinear models achieve F1 scores above 0.98 already at 10 ms, while lower-capacity models degrade at shorter horizons but improve with longer windows, indicating that relevant fault-type information is already present in the earliest transient. For FL, the top-performing models reach a stable localization error of about 10 % of normalized line length across all evaluated horizons, while weaker models form a clearly separated second performance tier. Line-resolved analysis shows that localization accuracy varies across grid segments, indicating topology-dependent difficulty rather than insufficient temporal context alone. These findings provide a controlled reference for comparing machine learning models across two protection tasks with fundamentally different information requirements.

cs.AI↗

Parameter-Efficient Domain Adaptation of Physics-Informed Self-Attention based GNNs for AC Power Flow Prediction

Accurate AC power flow (AC-PF) prediction under domain shift is critical when models trained on medium-voltage (MV) grids are deployed on high-voltage (HV) networks. Existing physics-informed graph neural network (GNN) solvers typically rely on full fine-tuning for cross-regime transfer, incurring high retraining cost and offering limited control over the stability-plasticity trade-off between target-domain adaptation and source-domain retention. We study parameter-efficient domain adaptation for physics-informed self-attention-based GNNs, encouraging Kirchhoff-consistent behavior via a physics-based loss while restricting adaptation to low-rank updates. Specifically, we apply low-rank adaptation (LoRA) to attention projections with selective unfreezing of the prediction head to regulate adaptation capacity. This design yields a controllable efficiency-accuracy trade-off for physics-constrained inverse estimation under voltage-regime shift. Across multiple grid topologies, the proposed LoRA+PHead adaptation recovers near-full fine-tuning accuracy with a target-domain RMSE gap of $2.6 \times 10^{-4}$ while reducing the number of trainable parameters by $85.46\%$. The physics-based residual remains comparable to full fine-tuning; however, relative to Full FT, LoRA+PHead reduces MV source retention by 4.7 percentage points (17.9% vs. 22.6%) under domain shift, while still enabling parameter-efficient and physically consistent AC-PF estimation.

cs.LG↗

Feature Selection for Fault Prediction in Distribution Systems

While conventional power system protection isolates faulty components only after a fault has occurred, fault prediction approaches try to detect faults before they can cause significant damage. Although initial studies have demonstrated successful proofs of concept, development is hindered by scarce field data and ineffective feature selection. To address these limitations, this paper proposes a surrogate task that uses simulation data for feature selection. This task exhibits a strong correlation (r = 0.92) with real-world fault prediction performance. We generate a large dataset containing 20000 simulations with 34 event classes and diverse grid configurations. From 1556 candidate features, we identify 374 optimal features. A case study on three substations demonstrates the effectiveness of the selected features, achieving an F1-score of 0.80 and outperforming baseline approaches that use frequency-domain and wavelet-based features.