SearcharxivSearch

arXiv subjects

Junlang Li

Publications and source records attributed to Junlang Li.

3 recordsLinked to original sources

DC response of an interferometer topology with an L-shaped cavity: a tabletop study

A new interferometer topology for kilohertz gravitational-wave detection was recently proposed in [Zhang et al. Phys. Rev. X 13, 021019 (2023)]. The design is based on an L-shaped optical cavity pumped through a Sagnac-like vortex. We report a tabletop experiment that characterizes the interferometer's optical response near DC. When the laser frequency is locked to the resonance of the L-shaped cavity, we observe that the cavity input coupler becomes effectively transparent, yielding a simple Michelson-like response. Moreover, the Sagnac vortex separates into upper and lower paths, which behave as two independent pumping paths driving the cavity. These observations are in agreement with theoretical predictions. Our results provide an intuitive physical picture of this interferometer topology and offer insight into its lock acquisition strategy.

physics.ins-det

Beijing Normal University 12-meter Interferometric kHz GW Detector Prototype: Design and Scientific Prospects

Current gravitational-wave detectors have achieved remarkable sensitivity around 100 Hz, enabling ground-breaking discoveries. Enhancing sensitivity at higher frequencies in the kilohertz (kHz) range promises access to rich physics, particularly the extreme conditions during the merger stage of binary neutron stars. However, the high-frequency sensitivity of Michelson-based interferometers is fundamentally limited by their linear optical cavities, which are optimized for low-frequency signal enhancement. In [Phys. Rev. X 13, 021019 (2023)], a new configuration employing an L-shaped optical resonator was proposed to overcome this limitation, offering exceptional sensitivity in the kHz band. As a pathfinder, the 12-meter prototype at Beijing Normal University is designed to demonstrate the sensing and control schemes of this new kHz detector configuration and to explore its performance in the high-power regime with suspended optics. Beyond its primary scientific goal, the prototype also offers potential sensitivity in the megahertz (MHz) range, potentially enabling constraints on exotic sources. This paper presents an overview of the prototype, including its optical design and current development status of key components.

physics.optics

Study of acceleration measurement in gravitational wave detection

Position-meter and speed-meter interferometers have been analysed for detecting gravitational waves. We introduce the concept of acceleration measurement in comparison with position and speed measurement. In this paper, we describe a general acceleration measurement and derive its standard quantum limit. We provide an example of an acceleration-meter interferometer configuration. We show that shot noise dominates at low frequency following a frequency dependence of $1/\Omega^2$, while radiation pressure noise is constant. The acceleration-meter has even a stronger radiation pressure noise suppression than speed-meter.

gr-qc