SearcharxivSearch

arXiv subjects

Junseon Park

Publications and source records attributed to Junseon Park.

3 recordsLinked to original sources

Co-Optimization of Network Topology and Variable Impedance Devices under Dynamic Line Ratings in Power Transmission Systems

Power system operators are increasingly deploying Grid Enhancing Technologies (GETs) to mitigate operational challenges such as line and transformer congestion, and voltage violations. These technologies, including Network Topology Optimization (NTO), Variable Impedance Devices (VIDs), and Dynamic Line Rating (DLR), enhance system flexibility and enable better utilization of existing network assets. However, as the deployment of multiple GETs grows, effective coordination among them becomes essential to fully realize their potential benefits. This paper presents a co-optimization framework that models and coordinates NTO, VID, and DLR within a unified optimization scheme to alleviate network congestion and minimize operational costs. The NTO formulation is developed using a node-breaker model, offering finer switching granularity and improved operational flexibility. The inclusion of VIDs introduces nonlinear and non-convex relationships in the optimization problem. DLR takes into account of weather conditions, primarily wind speed and ambient temperature, enabling adaptive utilization of transmission capacity. The proposed framework is validated on standard IEEE benchmark test systems, demonstrating its effectiveness under varying numbers and placements of impedance controllers.

eess.SY

Iterative McCormick Relaxation for Joint Impedance Control and Network Topology Optimization

Power system operators are increasingly deploying Variable Impedance Devices (VIDs), e.g., Smart Wires, and Network Topology Optimization (NTO) schemes for mitigating operational challenges such as line and transformer congestion, and voltage violations. This work aims to optimize and coordinate the operation of distributed VIDs considering fixed and optimized topologies. This problem is inherently non-linear due to power flow equations as well as bilinear terms introduced due to variable line impedance of VIDs. Furthermore, the topology optimization scheme makes it a mixed integer nonlinear problem. To tackle this, we introduce using McCormick relaxation scheme, which converts the bilinear constraints into a linear set of constraints along with the DC power flow equations. We propose an iterative correction of the McCormick relaxation to enhance its accuracy. The proposed framework is validated on standard IEEE benchmark test systems, and we present a performance comparison of the iterative McCormick method against the non-linear, SOS2 piecewise linear approximation, and original McCormick relaxation.

eess.SY

Rethinking Static Line Rating for Economic and Efficient Power Operation in South Korea

In South Korea, power grid is currently operated based on the static line rating (SLR) method, where the transmission line capacity is determined based on extreme weather conditions. However, with global warming, there is a concern that the temperatures during summer may exceed the SLR criteria, posing safety risks. On the other hand, the conservative estimates used for winter conditions limit the utilization of renewable energy. Proposals to install new lines face significant financial and environmental hurdles, complicating efforts to adapt to these changing conditions. Dynamic Line Rating (DLR) offers a real-time solution but requires extensive weather monitoring and complex integration. This paper proposes a novel method that improves on SLR by analyzing historical data to refine line rating criteria on a monthly, seasonal, and semi-annual basis. Through simulations, we show our approach significantly enhances cost effectiveness and reliability of the power system, achieving efficiencies close to DLR with existing infrastructure. This method offers a practical alternative to overcome the limitations of SLR and the implementation challenges of DLR.

eess.SY