SearcharxivSearch

arXiv subjects

Juntao Pan

Publications and source records attributed to Juntao Pan.

3 recordsLinked to original sources

First Demonstration of Optical Feedback Control to Parametric Instability at Advanced LIGO

Increasing the circulating power in gravitational-wave detectors to the megawatt level is essential for future sensitivity improvement, but this is critically limited by optomechanical parametric instabilities. Current mitigation strategies are projected to be inadequate against instabilities when circulating power reaches a megawatt. Optical feedback offers a novel independent paradigm to mitigate parametric instability. In this Letter, we report the first demonstration of optical feedback control in a full-scale gravitational wave detector. We successfully suppressed an unstable mode at 10.428 kHz, reducing the parametric gain from R = 2 to R < 0.02. This work validates optical feedback control as an effective mitigation scheme for kilometre-scale interferometric gravitational-wave detectors, providing an effective strategy to allow detectors to reach the megawatt level.

gr-qc

A Novel Arm-Length Stabilization Scheme for Gravitational-Wave Detectors with AlGaAs/GaAs Coated Mirrors

The arm length stabilisation system is employed in gravitational-wave detectors to reduce the velocity of the mirrors such that the arm cavities can be brought onto resonance in a controlled manner required to attain the detector operating point. For future upgrades of current gravitational wave detectors such as A#, which will incorporate AlGaAs/GaAs coatings, the current frequency-doubled arm length stabilisation system is unsuitable due to excessive absorption of the frequency-doubled 532nm beam by the AlGaAs/GaAs coating. We propose a novel multi-wavelength arm length stabilisation scheme that uses both frequency-doubled and frequency-tripled beams. The 1596nm auxiliary locking beam is outside the absorption bands of AlGaAs/GaAs coating. It is frequencytripled to 532nm and phase-locked with the 1064nm science laser through its second harmonic at 532 nm. In a tabletop setup, we experimentally demonstrated the stable cavity detuning and robust cavity locking transition by controlling the 1596nm laser and 1064nm laser phase locked loop. This demonstration confirmed that the proposed novel arm length stabilisation scheme is compatible with future upgrades or third-generation gravitational wave detectors that use AlGaAs/GaAs-coated test masses.

physics.optics

Demonstration of optical spring in an un-detuned cavity containing an optical parametric amplifier

Here we demonstrate the capacity to manipulate the optical spring (OS) effect by employing an optical parametric amplifier (OPA) within an optical cavity. We observed more than a factor of 2 increase in the OS frequency shift with the OPA. We also showed for the first time that the OS can be tuned by solely adjusting the OPA phase and showing an un-detuned cavity exhibiting an optical spring. The method can be applied to gravitational wave detectors in the signal recycling configuration to realize narrow bandwidth high sensitivity. The OS can be tuned to align the detector peak sensitivity frequency to known frequency continuous gravitational wave signals, dynamically tuned to track the gravitational wave signal from merging compact binaries or tuned to search for the post-merger signal of known binary coalescence.

physics.optics