SearcharxivSearch

arXiv subjects

Justin E. Bird

Publications and source records attributed to Justin E. Bird.

2 recordsLinked to original sources

A Single-Fiber Optical Frequency Domain Reflectometry (OFDR)-Based Shape Sensing of Concentric Tube Steerable Drilling Robots

This paper introduces a novel shape-sensing approach for Concentric Tube Steerable Drilling Robots (CT-SDRs) based on Optical Frequency Domain Reflectometry (OFDR). Unlike traditional FBG-based methods, OFDR enables continuous strain measurement along the entire fiber length with enhanced spatial resolution. In the proposed method, a Shape Sensing Assembly (SSA) is first fabricated by integrating a single OFDR fiber with a flat NiTi wire. The calibrated SSA is then routed through and housed within the internal channel of a flexible drilling instrument, which is guided by the pre-shaped NiTi tube of the CT-SDR. In this configuration, the drilling instrument serves as a protective sheath for the SSA during drilling, eliminating the need for integration or adhesion to the instrument surface that is typical of conventional optical sensor approaches. The performance of the proposed SSA, integrated within the cannulated CT-SDR, was thoroughly evaluated under free-bending conditions and during drilling along multiple J-shaped trajectories in synthetic Sawbones phantoms. Results demonstrate accurate and reliable shape-sensing capability, confirming the feasibility and robustness of this integration strategy.

cs.RO

Comparative Analysis of Autonomous Robotic and Manual Techniques for Ultrasonic Sacral Osteotomy: A Preliminary Study

In this paper, we introduce an autonomous Ultrasonic Sacral Osteotomy (USO) robotic system that integrates an ultrasonic osteotome with a seven-degree-of-freedom (DoF) robotic manipulator guided by an optical tracking system. To assess multi-directional control along both the surface trajectory and cutting depth of this system, we conducted quantitative comparisons between manual USO (MUSO) and robotic USO (RUSO) in Sawbones phantoms under identical osteotomy conditions. The RUSO system achieved sub-millimeter trajectory accuracy (0.11 mm RMSE), an order of magnitude improvement over MUSO (1.10 mm RMSE). Moreover, MUSO trials showed substantial over-penetration (16.0 mm achieved vs. 8.0 mm target), whereas the RUSO system maintained precise depth control (8.1 mm). These results demonstrate that robotic procedures can effectively overcome the critical limitations of manual osteotomy, establishing a foundation for safer and more precise sacral resections.

cs.RO