SearcharxivSearch

arXiv subjects

Justin Weigand

Publications and source records attributed to Justin Weigand.

2 recordsLinked to original sources

Deformable Registration of MRA and 4D Flow Images to Facilitate Accurate Estimation of Flow Properties within Blood Vessels

A method is presented for the registration of MRA and 4D Flow images, with the goal of calculating blood flow properties using both modalities simultaneously. In particular, the method produces an alignment of segmentations of vessel networks, from MRA images, with the blood velocity field within those networks, from the corresponding 4D Flow images. The alignment procedure is driven by the registration of centerlines of vessels extracted from the two modalities. Our approach is robust to noise, small deformations, and partial omissions of vessel surfaces and/or blood velocities. The alignment procedure is tested on 7 patient data sets acquired at Texas Children's Hospital. The quality of the resulting alignment is assessed by (i) an illustration of the aligned and unaligned surface segmentations for a sample patient, (ii) histograms of distances between centerline networks, and (iii) graphs of estimated blood flow. For each of the 7 analyzed data sets, medians of the distance histograms decreased an average of 83.5%, and the estimated blood flow increased significantly as a result of the alignment procedure.

q-bio.QM

Deep Learning Pipeline for Preprocessing and Segmenting Cardiac Magnetic Resonance of Single Ventricle Patients from an Image Registry

Purpose: To develop and evaluate an end-to-end deep learning pipeline for segmentation and analysis of cardiac magnetic resonance images to provide core-lab processing for a multi-centre registry of Fontan patients. Materials and Methods: This retrospective study used training (n = 175), validation (n = 25) and testing (n = 50) cardiac magnetic resonance image exams collected from 13 institutions in the UK, US and Canada. The data was used to train and evaluate a pipeline containing three deep-learning models. The pipeline's performance was assessed on the Dice and IoU score between the automated and reference standard manual segmentation. Cardiac function values were calculated from both the automated and manual segmentation and evaluated using Bland-Altman analysis and paired t-tests. The overall pipeline was further evaluated qualitatively on 475 unseen patient exams. Results: For the 50 testing dataset, the pipeline achieved a median Dice score of 0.91 (0.89-0.94) for end-diastolic volume, 0.86 (0.82-0.89) for end-systolic volume, and 0.74 (0.70-0.77) for myocardial mass. The deep learning-derived end-diastolic volume, end-systolic volume, myocardial mass, stroke volume and ejection fraction had no statistical difference compared to the same values derived from manual segmentation with p values all greater than 0.05. For the 475 unseen patient exams, the pipeline achieved 68% adequate segmentation in both systole and diastole, 26% needed minor adjustments in either systole or diastole, 5% needed major adjustments, and the cropping model only failed in 0.4%. Conclusion: Deep learning pipeline can provide standardised 'core-lab' segmentation for Fontan patients. This pipeline can now be applied to the >4500 cardiac magnetic resonance exams currently in the FORCE registry as well as any new patients that are recruited.

cs.CV