SearcharxivSearch

arXiv subjects

K. Deng

Publications and source records attributed to K. Deng.

3 recordsLinked to original sources

Thermal noise limited higher-order mode locking of a reference cavity

Higher-order mode locking has been proposed to reduce the thermal noise limit of reference cavities. By locking a laser to the HG02 mode of a 10-cm long all ULE cavity, and measure its performance with the three-cornered-hat method among three independently stabilized lasers, we demonstrate a thermal noise limited performance of a fractional frequency instability of 4.9E-16. The results match the theoretical models with higher-order optical modes. The achieved laser instability improves the all ULE short cavity results to a new low level.

physics.ins-det

Direct laser cooling Al+ ions optical clocks

Al$^+$ ions optical clock is a very promising optical frequency standard candidate due to its extremely small blackbody radiation shift. It has been successfully demonstrated with indirect cooled, quantum-logic-based spectroscopy technique. Its accuracy is limited by second-order Doppler shift, and its stability is limited by the number of ions that can be probed in quantum logic processing. We propose a direct laser cooling scheme of Al$^+$ ions optical clocks where both the stability and accuracy of the clocks are greatly improved. In the proposed scheme, two Al$^+$ ions traps are utilized. The first trap is used to trap a large number of Al$^+$ ions to improve the stability of the clock laser, while the second trap is used to trap a single Al$^+$ ions to provide the ultimate accuracy. Both traps are cooled with a continuous wave 167 nm laser. The expected clock laser stability can reach $9.0\times10^{-17}/\sqrtτ$. For the second trap, in addition to 167 nm laser Doppler cooling, a second stage pulsed 234 nm two-photon cooling laser is utilized to further improve the accuracy of the clock laser. The total systematic uncertainty can be reduced to about $1\times10^{-18}$. The proposed Al$^+$ ions optical clock has the potential to become the most accurate and stable optical clock.

physics.atom-ph

Design of an optical reference cavity with low thermal noise and flexible thermal expansion properties

An ultrastable optical reference cavity with re-entrant fused silica mirrors and a ULE spacer structure is designed through finite element analysis. The designed cavity has a low thermal noise limit of $1\times10^{-16}$ and a flexible zero crossing temperature of the effective coefficient of thermal expansion (CTE). The CTE zero crossing temperature difference between a composite cavity and a pure ULE cavity can be tuned from $-10\ ^{\circ}$C to $23\ ^{\circ}$C, which enables operation of the designed reference cavity near room temperature without worrying about the CTE zero crossing temperature of the ULE spacer. The design can be applied to cavities with different lengths. Vibration immunity of the cavity is also achieved through structure optimization.

physics.optics