Searcharxiv⌕ Search

arXiv subjects

K. E. Shestermanov

Publications and source records attributed to K. E. Shestermanov.

9 recordsLinked to original sources

Expected Accuracy in a Measurement of the CKM Angle $α$ Using a Dalitz Plot Analysis of $\boldmath B^0 \to ρπ$ Decays in the BTeV Project

A precise measurement of the angle $α$ in the CKM triangle is very important for a complete test of Standard Model. A theoretically clean method to extract $α$ is provided by B$^0 \to ρπ$ decays. Monte Carlo simulations to obtain the BTeV reconstruction efficiency and to estimate the signal to background ratio for these decays were performed. Finally the time-dependent Dalitz plot analysis, using the isospin amplitude formalism for tree and penguin contributions, was carried out. It was shown that in one year of data taking BTeV could achieve an accuracy on $α$ better than 5$^{\circ}$.

hep-ex↗

Design and performance of LED calibration system prototype for the lead tungstate crystal calorimeter

A highly stable monitoring system based on blue and red light emitting diodes coupled to a distribution network comprised of optical fibers has been developed for an electromagnetic calorimeter that uses lead tungstate crystals readout with photomultiplier tubes. We report of the system prototype design and on the results of laboratory tests. Stability better than 0.1% (r.m.s.) has been achieved during one week of prototype operation.

physics.ins-det↗

Correlation of Beam Electron and LED Signal Losses under Irradiation and Long-term Recovery of Lead Tungstate Crystals

Radiation damage in lead tungstate crystals reduces their transparency. The calibration that relates the amount of light detected in such crystals to incident energy of photons or electrons is of paramount importance to maintaining the energy resolution the detection system. We report on tests of lead tungstate crystals, read out by photomultiplier tubes, exposed to irradiation by monoenergetic electron or pion beams. The beam electrons themselves were used to measure the scintillation light output, and a blue light emitting diode (LED) was used to track variations of crystals transparency. We report on the correlation of the LED measurement with radiation damage by the beams and also show that it can accurately monitor the crystals recovery from such damage.

physics.ins-det↗

Future of low-x forward physics at RHIC

The rapidity dependence of inclusive and coincident particle production in d(p)+Au collisions at RHIC can be used to probe nuclear parton distribution functions down to small momentum fractions where theory anticipates that parton saturation could be present. This paper describes how such experiments could be completed.

hep-ex↗

Single spin asymmetry measurements for $π^0$ inclusive productions in $p+p_{\uparrow} \to π^0 + X$ and $π^-+\p_{\uparrow}\to π^0+X$ reactions at 70 and 40 GeV respectively

The inclusive $π^0$ asymmetries were measured in reactions $p+p\uparrow \to π^0+X$ and $π^-+p\uparrow \to π^0+X$ at 70 and 40 GeV/c respectively. The measurements were made at the central region (for the first reaction) and asymmetry is compatible with zero in the entire measured $p_T$ region. For the second reaction the asymmetry is zero for small $x_F$ region ($-0.4<x_F<-0.1, 0.5<p_T(GeV/c) <1.5$) and increases with growth of $\mid x_F\mid$. Averaged over the interval $-0.8<x_F<-0.4, 1<p_T(GeV/c)<2$ the asymmetry was $-(13.8\pm 3.8)%$.

hep-ex↗

$A_N$ at small negative values of $\xf$ in the reaction $p+p(pol) \to π^0+X$ at 70 GeV and universal threshold in inclusive pion production

The talk continues the series of Single Spin Asymmetry (SSA) $π^0$ inclusive measurements carried out at Protvino 70 GeV accelerator. The asymmetry in the polarized target fragmentation region grows up in absolute value with $\xf$ decreasing and equals to $(-16 \pm 5)%$ at $-0.4<\xf<-0.25$. The result of the current experiment is in agreement with the universal threshold in pion asymmetries.

hep-ex↗

Study of Possible Scintillation Mechanism Damage in PbWO4 Crystals After Pion Irradiation

We employed two independent methods to study possible damage to the scintillation mechanism in lead tungstate crystals due to irradiation by a 34 GeV pion beam. First, 10 crystals were irradiated simultaneously over 30 hours by a narrow beam, so that only a small region of each crystal was affected. We studied the effect of the irradiation on the light output non-uniformity. If a localized degradation was observed, it would indicate damage to the scintillation mechanism. Secondly, we detected light output using two phototubes attached to sides of a crystal. Since these phototubes detect scintillation light only from a small localized region, the effect of transmission loss should be minimal. We did not see any statistically significant evidence for scintillation mechanism damage with either method. The effect is consistent with zero, and the upper limit is 0.5% at 95% C.L.

physics.ins-det↗

Development of a Momentum Determined Electron Beam in the 1 -45 GeV Range

A beam line for electrons with energies in the range of 1 to 45 GeV, low contamination of hadrons and muons and high intensity up to 10^6 per accelerator spill at 27 GeV was setup at U70 accelerator in Protvino, Russia. A beam tagging system based on drift chambers with 160 micron resolution was able to measure relative electron beam momentum precisely. The resolution sigma_p p was 0.13% at 45 GeV where multiple scattering is negligible. This test beam setup provided the possibility to study properties of lead tungstate crystals (PbWO_4) for the BTeV experiment at Fermilab.

hep-ex↗

STAR Barrel Electromagnetic Calorimeter Absolute Calibration Using "Minimum Ionizing Particles" from Collisions at RHIC

The procedure for the STAR Barrel Electromagnetic Calorimeter (BEMC) absolute calibrations, using penetrating charged particle hits (MIP-hits) from physics events at RHIC, is presented. Its systematic and statistical errors are evaluated. It is shown that, using this technique, the equalization and transfer of the absolute scale from the test beam can be done to a percent level accuracy in a reasonable amount of time for the entire STAR BEMC. MIP-hits would also be an effective tool for continuously monitoring the variations of the BEMC tower's gains, virtually without interference to STAR's main physics program. The method does not rely on simulations for anything other than geometric and some other small corrections, and also for estimations of the systematic errors. It directly transfers measured test beam responses to operations at RHIC.

hep-ex↗