SearcharxivSearch

arXiv subjects

K. Francis

Publications and source records attributed to K. Francis.

At least 19 recordsLinked to original sources

Cryogenic characterization of FBK NUV-HD-Cryo 3T SiPM sensors for the DUNE photon detection system

The Deep Underground Neutrino Experiment (DUNE) is a long-baseline neutrino experiment based in the USA and composed of a Near Detector (ND) complex at Fermi National Laboratory (FNAL), and a Far Detector (FD) complex located at the Sanford Underground Research Facility (SURF) $\sim$1300\,km distant. DUNE will study neutrino oscillations looking for unresolved issues of the Standard Model of particle physics (SM) such as CP violation in the leptonic sector, neutrino mass ordering and others, starting from the early 2030s. The FD, with a mass of $\sim$17\,kt, that will exploit both ionization and scintillation signals to detect neutrino interactions with Argon. Scintillating photons in LAr will be detected by the photon detection system (PDS) based on light collectors coupled to Silicon Photomultipliers (SiPMs). During a test campaign, different laboratories of the collaboration performed an investigation of the best SiPM candidates that fulfill the DUNE FD requirements. We identified two models of SiPM, produced by Hamamatsu Photonics K.K. (HPK) and Fondazione Bruno Kessler (FBK), respectively. In this paper, we focus on the FBK selected model showing its main features. We will describe the characterization protocol, the results at both room and cryogenic temperatures and the photon detection efficiency measurements.

physics.ins-det

The ILD Detector: A Versatile Detector for an Electron-Positron Collider at Energies up to 1 TeV

The International Large Detector, ILD, is a detector concept for an experiment at a future high energy lepton collider. The detector has been optimised for precision physics in a range of energies from 90~GeV to about 1~TeV. ILD features a high precision, large volume combined silicon and gaseous tracking system, together with a high granularity calorimeter, all inside a central solenoidal magnetic field. The paradigm of particle flow has been the guiding principle of the design of ILD. ILD is based mostly on technologies which have been demonstrated by extensive research and test programs. The ILD concept is proposed both for linear and circular lepton collider, be it at CERN or elsewhere. The concept has been developed by a group of nearly 60 institutes from around the world, and offers a well developed and powerful environment for science and technology studies at lepton colliders. In this document, the required performance of the detector, the proposed implementation and the readiness of the different technologies needed for the implementation are discussed.

hep-ex

Software Compensation for Highly Granular Calorimeters using Machine Learning

A neural network for software compensation was developed for the highly granular CALICE Analogue Hadronic Calorimeter (AHCAL). The neural network uses spatial and temporal event information from the AHCAL and energy information, which is expected to improve sensitivity to shower development and the neutron fraction of the hadron shower. The neural network method produced a depth-dependent energy weighting and a time-dependent threshold for enhancing energy deposits consistent with the timescale of evaporation neutrons. Additionally, it was observed to learn an energy-weighting indicative of longitudinal leakage correction. In addition, the method produced a linear detector response and outperformed a published control method regarding resolution for every particle energy studied.

physics.ins-det

Cryogenic front-end amplifier design for large SiPM arrays in the DUNE FD1-HD photon detection system

The photon detection system of the first far detector (FD1-HD) of the DUNE experiment will detect scintillation photons produced by particle interactions in a kiloton-scale liquid Argon time projection chamber. The photon detectors of choice are silicon photomultipliers (SiPM), 6$\times$6 mm$^2$ each, arranged in groups of 48, which present a significantly low impedance to the front-end electronics. This paper details the design of a cryogenic amplifier with exceptionally low white voltage noise of 0.37 nV$\sqrt{Hz}$, based on a silicon-germanium input transistor and a BiCMOS fully differential operational amplifier. It yields excellent single photoelectron resolution even at low overvoltage values. The signal rise time is below 100 ns, and the dynamic range is about 2000 photoelectrons at the typical operating overvoltage. It draws 0.7 mA from a single 3.3 V supply, for a power consumption of 2.4 mW per channel. Simplified models were developed to predict the single photolectron signal shape and the signal to noise ratio, with a good match to measured performance.

physics.ins-det

Cryogenic SiPM arrays for the DUNE photon detection system

In this paper we report on the characterization of SiPM tiles developed for the R & D on the DUNE Photon Detection System. The tiles were produced by Fondazione Bruno Kessler (FBK) employing NUV-HD-SF SiPMs. Special emphasis is given on cryo-reliability of the sensors, i.e. the stability of electric and mechanical properties after thermal cycles at room and 77K temperature. The characterization includes the determination of the I-V curve, a high sensitivity measurement of Dark Count Rate at different overvoltages, and correlated noise. The single p.e. sensitivity is measured as a function of the number of sensors connected to a single electronic channel, after amplification at 77K using a dedicated cold amplifier.

physics.ins-det

Characterisation of different stages of hadronic showers using the CALICE Si-W ECAL physics prototype

A detailed investigation of hadronic interactions is performed using $π^-$-mesons with energies in the range 2--10 GeV incident on a high granularity silicon-tungsten electromagnetic calorimeter. The data were recorded at FNAL in 2008. The region in which the $π^-$-mesons interact with the detector material and the produced secondary particles are characterised using a novel track-finding algorithm that reconstructs tracks within hadronic showers in a calorimeter in the absence of a magnetic field. The principle of carrying out detector monitoring and calibration using secondary tracks is also demonstrated.

physics.ins-det

Radiation Tests of Hamamatsu Multi-Pixel Photon Counters

Results of radiation tests of Hamamatsu 2.0 x 2.0~mm2 through-silicon-via (S13360-2050VE) multi-pixel photon counters, or MPPCs [1], are presented. Distinct sets of eight MPPCs were exposed to four different 1~MeV neutron equivalent doses of 200 MeV protons. Measurements of the breakdown voltage, gain and noise rates at different bias overvoltages, photoelectron thresholds, and LED illumination levels were taken before and after irradiation. No significant deterioration in performance was observed for breakdown voltage, gain, and response. Noise rates increased significantly with irradiation. These studies were undertaken in the context of MPPC requirements for the Cosmic Ray Veto detector of the Mu2e experiment at the Fermi National Accelerator Laboratory.

physics.ins-det

Analysis of Testbeam Data of the Highly Granular RPC-Steel CALICE Digital Hadron Calorimeter and Validation of Geant4 Monte Carlo Models

We present a study of the response of the highly granular Digital Hadronic Calorimeter with steel absorbers, the Fe-DHCAL, to positrons, muons, and pions with momenta ranging from 2 to 60 GeV/c. Developed in the context of the CALICE collaboration, this hadron calorimeter utilises Resistive Plate Chambers as active media, interspersed with steel absorber plates. With a transverse granularity of $1\,\times\,1\,$cm$^{2}$ and a longitudinal segmentation of 38 layers, the calorimeter counted 350,208 readout channels, each read out with single-bit resolution (digital readout). The data were recorded in the Fermilab test beam in 2010-11. The analysis includes measurements of the calorimeter response and the energy resolution to positrons and muons, as well as detailed studies of various shower shape quantities. The results are compared to simulations based on Geant4, which utilise different electromagnetic and hadronic physics lists.

physics.ins-det

Hadronic Energy Resolution of a Combined High Granularity Scintillator Calorimeter System

This paper presents results obtained with the combined CALICE Scintillator Electromagnetic Calorimeter, Analogue Hadronic Calorimeter and Tail Catcher & Muon Tracker, three high granularity scintillator-SiPM calorimeter prototypes. The response of the system to pions with momenta between 4 GeV/c and 32 GeV/c is analysed, including the energy response, resolution, and longitudinal shower profiles. The results of a software compensation technique based on weighting according to hit energy are compared to those of a standard linear energy reconstruction. The results are compared to predictions of the GEANT4 physics lists QGSP_BERT_HP and FTFP_BERT_HP.

physics.ins-det

Construction and Response of a Highly Granular Scintillator-based Electromagnetic Calorimeter

A highly granular electromagnetic calorimeter with scintillator strip readout is being developed for future lepton collider experiments. A prototype of 21.5 $X_0$ depth and $180 \times 180 $mm$^2$ transverse dimensions was constructed, consisting of 2160 individually read out $10 \times 45 \times 3$ mm$^3$ scintillator strips. This prototype was tested using electrons of 2--32 GeV at the Fermilab Test Beam Facility in 2009. Deviations from linear energy response were less than 1.1\%, and the intrinsic energy resolution was determined to be $(12.5 \pm 0.1 (\mathrm{stat.}) \pm0.4 (\mathrm{syst.}))\%/\sqrt{E[\mathrm{GeV}]}\oplus (1.2 \pm 0.1(\mathrm{stat.})^{+0.6}_{-0.7}(\mathrm{syst.}))\%$, where the uncertainties correspond to statistical and systematic sources, respectively.

physics.ins-det

Design, Construction and Testing of the Digital Hadron Calorimeter (DHCAL) Electronics

A novel hadron calorimeter is being developed for future lepton colliding beam detectors. The calorimeter is optimized for the application of Particle Flow Algorithms (PFAs) to the measurement of hadronic jets and features a very finely segmented readout with 1 x 1 cm2 cells. The active media of the calorimeter are Resistive Plate Chambers (RPCs) with a digital, i.e. one-bit, readout. To first order the energy of incident particles in this calorimeter is reconstructed as being proportional to the number of pads with a signal over a given threshold. A large-scale prototype calorimeter with approximately 500,000 readout channels has been built and underwent extensive testing in the Fermilab and CERN test beams. This paper reports on the design, construction, and commissioning of the electronic readout system of this prototype calorimeter. The system is based on the DCAL front-end chip and a VME-based back-end.

physics.ins-det

DHCAL with Minimal Absorber: Measurements with Positrons

In special tests, the active layers of the CALICE Digital Hadron Calorimeter prototype, the DHCAL, were exposed to low energy particle beams, without being interleaved by absorber plates. The thickness of each layer corresponded approximately to 0.29 radiation lengths or 0.034 nuclear interaction lengths, defined mostly by the copper and steel skins of the detector cassettes. This paper reports on measurements performed with this device in the Fermilab test beam with positrons in the energy range of 1 to 10 GeV. The measurements are compared to simulations based on GEANT4 and a standalone program to emulate the detailed response of the active elements.

physics.ins-det

Design, Construction and Commissioning of the Digital Hadron Calorimeter - DHCAL

A novel hadron calorimeter is being developed for future lepton colliding beam detectors. The calorimeter is optimized for the application of Particle Flow Algorithms (PFAs) to the measurement of hadronic jets and features a very finely segmented readout with 1 x 1 cm2 cells. The active media of the calorimeter are Resistive Plate Chambers (RPCs) with a digital, i.e. one-bit, readout. To first order the energy of incident particles in this calorimeter is reconstructed as being proportional to the number of pads with a signal over a given threshold. A large-scale prototype calorimeter with approximately 500,000 readout channels has been built and underwent extensive testing in the Fermilab and CERN test beams. This paper reports on the design, construction, and commissioning of this prototype calorimeter.

physics.ins-det

Calibration and GEANT4 Simulations of the Phase II Proton Compute Tomography (pCT) Range Stack Detector

Northern Illinois University in collaboration with Fermi National Accelerator Laboratory (FNAL) and Delhi University has been designing and building a proton CT scanner for applications in proton treatment planning. The Phase II proton CT scanner consists of eight planes of tracking detectors with two X and two Y coordinate measurements both before and after the patient. In addition, a range stack detector consisting of a stack of thin scintillator tiles, arranged in twelve eight-tile frames, is used to determine the water equivalent path length (WEPL) of each track through the patient. The X-Y coordinates and WEPL are required input for image reconstruction software to find the relative (proton) stopping powers (RSP) value of each voxel in the patient and generate a corresponding 3D image. In this Note we describe tests conducted in 2015 at the proton beam at the Central DuPage Hospital in Warrenville, IL, focusing on the range stack calibration procedure and comparisons with the GEANT~4 range stack simulation.

physics.ins-det

Shower development of particles with momenta from 15 GeV to 150 GeV in the CALICE scintillator-tungsten hadronic calorimeter

We present a study of showers initiated by electrons, pions, kaons, and protons with momenta from 15 GeV to 150 GeV in the highly granular CALICE scintillator-tungsten analogue hadronic calorimeter. The data were recorded at the CERN Super Proton Synchrotron in 2011. The analysis includes measurements of the calorimeter response to each particle type as well as measurements of the energy resolution and studies of the longitudinal and radial shower development for selected particles. The results are compared to Geant4 simulations (version 9.6.p02). In the study of the energy resolution we include previously published data with beam momenta from 1 GeV to 10 GeV recorded at the CERN Proton Synchrotron in 2010.

physics.ins-det

Performance of Scintillator Counters with Silicon Photomultiplier Readout

The performance of scintillator counters with embedded wavelength-shifting fibers has been measured in the Fermilab Meson Test Beam Facility using 120 GeV protons. The counters were extruded with a titanium dioxide surface coating and two channels for fibers at the Fermilab NICADD facility. Each fiber end is read out by a 2*2 mm^2 silicon photomultiplier. The signals were amplified and digitized by a custom-made front-end electronics board. Combinations of 5*2 cm^2 and 6*2 cm^2 extrusion profiles with 1.4 and 1.8 mm diameter fibers were tested. The design is intended for the cosmic-ray veto detector for the Mu2e experiment at Fermilab. The light yield as a function of the transverse and longitudinal position of the beam will be given.

physics.ins-det

Testing Hadronic Interaction Models using a Highly Granular Silicon-Tungsten Calorimeter

A detailed study of hadronic interactions is presented using data recorded with the highly granular CALICE silicon-tungsten electromagnetic calorimeter. Approximately 350,000 selected negatively charged pion events at energies between 2 and 10 GeV have been studied. The predictions of several physics models available within the Geant4 simulation tool kit are compared to this data. A reasonable overall description of the data is observed; the Monte Carlo predictions are within 20% of the data, and for many observables much closer. The largest quantitative discrepancies are found in the longitudinal and transverse distributions of reconstructed energy.

physics.ins-det

Pion and proton showers in the CALICE scintillator-steel analogue hadron calorimeter

Showers produced by positive hadrons in the highly granular CALICE scintillator-steel analogue hadron calorimeter were studied. The experimental data were collected at CERN and FNAL for single particles with initial momenta from 10 to 80 GeV/c. The calorimeter response and resolution and spatial characteristics of shower development for proton- and pion-induced showers for test beam data and simulations using Geant4 version 9.6 are compared.

physics.ins-det