SearcharxivSearch

arXiv subjects

K. Hara

Publications and source records attributed to K. Hara.

At least 19 recordsLinked to original sources

Development for the Belle II vertex detector upgrade with depleted monolithic active pixel sensors

The vertex detector upgrade project for the Belle II experiment, based on CMOS depleted monolithic active pixel sensor technology, is planned to be carried out in conjunction with the major modification of the interaction region of the SuperKEKB collider during Long Shutdown 2 from 2032 to 2034. The MAPS sensor, named OBELIX currently under development, is derived from the successor to TJ-Monopix2, with modifications implemented to ensure compatibility with the Belle II trigger system. The new vertex detector consists of two layers of four self-supported consecutive OBELIX sensors, and three layers of discrete OBELIX sensors mounted on mechanical support structures with readout flex circuits attached to the sensors. The detector is arranged cylindrically around the beam pipe at radii ranging from 14 mm to 140 mm. The minimization of the material budget is required in order to enhance physics performance. We present an overview of the project and its latest developments, with particular emphasis on the development of low-material-budget flex circuits employing aluminum conductors.

physics.ins-det

Application of exhaustive simulation flow for advanced performance prediction of monolithic active pixel sensors

Monolithic active pixel sensor (MAPS) developments have pushed the detection performance in various directions, especially relative to timing where nanosecond-level precision is now considered. This evolution calls for a simultaneous upgrade of the simulation tools. We have developed a simulation flow that covers steps from the signal creation in the sensitive volume to the output of the pixel digital logic that performs the time-of-arrival and time-over-threshold (ToA/ToT) measurements. This approach adds several new features to the traditional use the of the TCAD - Allpix Squared duo, among which : the integration of the pixel wells from the layout in order to precisely describe the pixel key characteristics such as leakage and punch-through currents and the coupling of Monte Carlo simulations (Allpix Squared) with high precision electrical simulations (SPICE). The first (Allpix Squared) for the precise description of the current induced at the collection electrode and the second (SPICE) to guarantee high precision simulation of the front-end electronics using realistic signal events. Irradiation is also modeled, both from the charge propagation side (charge trapping) and from the front-end response side (high input signal discharge). We have applied this methodology to the MAPS developed in the context of the Belle II vertex detector upgrade. In this contribution, we detail the key features of the exhaustive simulation flow, present the outcome of the comparison with the TJ-Monopix2 measurements and discuss the interest of the methodology for the development of modern MAPS.

physics.ins-det

Radiation damage study of Belle II silicon strip sensors with 90 MeV electron irradiation

The silicon strip sensors of the Belle II silicon vertex detector were irradiated with 90 MeV electron beams up to an equivalent 1-MeV-neutron fluence of $3.0\times 10^{13}~{\rm n}_{\rm eq}/{\rm cm^2}$. We measure changes in sensor properties induced by radiation damage in the semiconductor bulk. Electrons around this energy are a major source of beam-induced background during Belle II operation. We discuss observed changes in full depletion voltage, sensor leakage current, noise, and charge collection. The sensor bulk type inverts at an equivalent 1-MeV-neutron fluence of $6.0\times 10^{12}~{\rm n}_{\rm eq}/{\rm cm^2}$. The leakage current increases proportionally to the radiation dose. We determine a damage constant of $3.9 \times 10^{-17}$ A/cm at 17 C$^\circ$ immediately after irradiation, which drops significantly to approximately 40% of the initial value in 200 hours, then stabilizes to approximately 30% of the initial value in 1000 hours. We measure sensor noise and signal charge for a sensor irradiated with the equivalent 1-MeV-neutron fluence of $3.0\times 10^{13}~{\rm n}_{\rm eq}/{\rm cm^2}$. Noise increases by approximately 44% after irradiation, while signal charge does not change significantly when a sufficiently high bias voltage is applied.

physics.ins-det

Status of the International Linear Collider

This paper is not a proposal for a CERN future project but provides information on the International Linear Collider (ILC) considered for Japan in order to facilitate the European Strategy discussion in a global context. It describes progress to date, ongoing engineering studies, updated cost estimate for the machine at $\sqrt{s}=250~\rm GeV$ and the situation in Japan. The physics of the ILC is not presented here, but jointly for all Linear Collider projects in a separate document ``A Linear Collider Vision for the Future of Particle Physics'' submitted for the forthcoming European Strategy deliberations.

hep-ex

Operational experience and performance of the Silicon Vertex Detector after the first long shutdown of Belle II

In 2024, the Belle II experiment resumed data taking after the Long Shutdown 1, which was required to install a two-layer pixel detector and upgrade accelerator components. We describe the challenges of this shutdown and the operational experience thereafter. With new data, the silicon-strip vertex detector (SVD) confirmed the high hit efficiency, the large signal-to-noise ratio, and the excellent cluster position resolution. In the coming years, the SuperKEKB peak luminosity is expected to increase to its target value, resulting in a larger SVD occupancy caused by beam background. Considerable efforts have been made to improve SVD reconstruction software by exploiting the excellent SVD hit-time resolution to determine the collision time and reject off-time particle hits. A novel procedure to group SVD hits event-by-event, based on their time, has been developed using the grouping information during reconstruction, significantly reducing the fake rate while preserving the tracking efficiency. The front-end chip (APV25) is operated in the multi-peak mode, which reads six samples. A 3/6-mixed acquisition mode, based on the timing precision of the trigger, reduces background occupancy, trigger dead-time, and data size. Studies of the radiation damage show that the SVD performance will not seriously degrade during the lifetime of the detector, despite moderate radiation-induced increases in sensor current and strip noise.

physics.ins-det

The Belle II Detector Upgrades Framework Conceptual Design Report

We describe the planned near-term and potential longer-term upgrades of the Belle II detector at the SuperKEKB electron-positron collider operating at the KEK laboratory in Tsukuba, Japan. These upgrades will allow increasingly sensitive searches for possible new physics beyond the Standard Model in flavor, tau, electroweak and dark sector physics that are both complementary to and competitive with the LHC and other experiments.

hep-ex

Silicon Vertex Detector of the Belle II Experiment

The silicon vertex detector (SVD) is installed at the heart of the Belle II experiment, taking data at the high-luminosity $B$-Factory SuperKEKB since 2019. The detector has shown a stable and above-99\% hit efficiency, with a large signal-to-noise in all sensors since the beginning of data taking. Cluster position and time resolution have been measured with 2020 and 2022 data and show excellent performance and stability. The effect of radiation damage is visible, but not affecting the performance. As the luminosity increases, higher machine backgrounds are expected and the excellent hit-time information in SVD can be exploited for background rejection. In particular, we have recently developed a novel procedure to select hits by grouping them event-by-event based on their time. This new procedure allows a significant reduction of the fake rate, while preserving the tracking efficiency, and it has therefore replaced the previous cut-based procedure. We have developed a method that uses the SVD hits to estimate the track time (previously unavailable) and the collision time. It has a similar precision to the estimate based on the drift chamber but its execution time is three orders of magnitude smaller, allowing a faster online reconstruction that is crucial in a high luminosity regime. The track time is a powerful information provided to analysis that allows, together with the above-mention grouping selection, to raise the occupancy limit above that expected at nominal luminosity, leaving room for a safety factor. Finally, in June 2022 the data taking of the Belle II experiment was stopped to install a new two-layer DEPFET detector (PXD) and upgrade components of the accelerator. The whole silicon tracker (PXD+SVD) has been extracted from Belle II, the new PXD installed, the detector closed and commissioned. We briefly describe the SVD results of this upgrade.

hep-ex

Measurement of the cluster position resolution of the Belle II Silicon Vertex Detector

The Silicon Vertex Detector (SVD), with its four double-sided silicon strip sensor layers, is one of the two vertex sub-detectors of Belle II operating at SuperKEKB collider (KEK, Japan). Since 2019 and the start of the data taking, the SVD has demonstrated a reliable and highly efficient operation, even running in an environment with harsh beam backgrounds that are induced by the world's highest instantaneous luminosity. In order to provide the best quality track reconstruction with an efficient pattern recognition and track fit, and to correctly propagate the uncertainty on the hit's position to the track parameters, it is crucial to precisely estimate the resolution of the cluster position measurement. Several methods for estimating the position resolution directly from the data will be discussed.

physics.ins-det

The Silicon Vertex Detector of the Belle II Experiment

In 2019 the Belle II experiment started data taking at the asymmetric SuperKEKB collider (KEK, Japan) operating at the Y(4S) resonance. Belle II will search for new physics beyond the Standard Model by collecting an integrated luminosity of 50~ab$^{-1}$. The silicon vertex detector (SVD), consisting of four layers of double-sided silicon strip sensors, is one of the two vertex sub-detectors. The SVD extrapolates the tracks to the inner pixel detector (PXD) with enough precision to correctly identify hits in the PXD belonging to the track. In addition the SVD has standalone tracking capability and utilizes ionization to enhance particle identification in the low momentum region. The SVD is operating reliably and with high efficiency, despite exposure to the harsh beam background of the highest peak-luminosity collider ever built. High signal-to-noise ratio and hit efficiency have been measured, as well as the spatial resolution; all these quantities show excellent stability over time. Data-simulation agreement on cluster properties has recently been improved through a careful tuning of the simulation. The precise hit-time resolution can be exploited to reject out-of-time hits induced by beam background, which will make the SVD more robust against higher levels of background. During the first three years of running, radiation damage effects on strip noise, sensor currents and depletion voltage have been observed, as well as some coupling capacitor failure due to intense radiation bursts. None of these effects cause significant degradation in the detector performance.

physics.ins-det

$B$-flavor tagging at Belle II

We report on new flavor tagging algorithms developed to determine the quark-flavor content of bottom ($B$) mesons at Belle II. The algorithms provide essential inputs for measurements of quark-flavor mixing and charge-parity violation. We validate and evaluate the performance of the algorithms using hadronic $B$ decays with flavor-specific final states reconstructed in a data set corresponding to an integrated luminosity of $62.8$ fb$^{-1}$, collected at the $\Upsilon$(4$S$) resonance with the Belle II detector at the SuperKEKB collider. We measure the total effective tagging efficiency to be $\varepsilon_{\rm eff} = \big(30.0 \pm 1.2(\text{stat}) \pm 0.4(\text{syst})\big)\%$ for a category-based algorithm and $\varepsilon_{\rm eff} = \big(28.8 \pm 1.2(\text{stat}) \pm 0.4(\text{syst})\big)\%$ for a deep-learning-based algorithm.

hep-ex

Performance of the diamond-based beam-loss monitor system of Belle II

We designed, constructed and have been operating a system based on single-crystal synthetic diamond sensors, to monitor the beam losses at the interaction region of the SuperKEKB asymmetric-energy electron-positron collider. The system records the radiation dose-rates in positions close to the inner detectors of the Belle II experiment, and protects both the detector and accelerator components against destructive beam losses, by participating in the beam-abort system. It also provides complementary information for the dedicated studies of beam-related backgrounds. We describe the performance of the system during the commissioning of the accelerator and during the first physics data taking.

physics.ins-det

Numerical analysis of azimuthal rotating spokes in a crossed-field discharge plasma

Low-frequency rotating spokes are obtained in a cross-field discharge plasma using two-dimensional numerical simulations. A particle-fluid hybrid model is used to model the plasma flow in a configuration similar to a Hall thruster. It has been reported that the drift-diffusion approximation for an electron fluid results in an ill-conditioned matrix when solving for the potential because of the differences in the electron mobilities across the magnetic field and in the direction of the E$\times$B drift. In this paper, we employ a hyperbolic approach that enables stable calculation, namely, better iterative convergence of the electron fluid model. Our simulation results show a coherent rotating structure propagating in the E$\times$B direction with a phase velocity of 2,500 m/s, which agrees with experimental data. The phase velocity obtained from the numerical simulations shows good agreement with that predicted by the dispersion relation of the gradient drift instability.

physics.plasm-ph

Measurement of the $τ$ lepton polarization and $R(D^*)$ in the decay $\bar{B} \rightarrow D^* τ^- \barν_τ$ with one-prong hadronic $τ$ decays at Belle

With the full data sample of $772 \times 10^6$ $B{\bar B}$ pairs recorded by the Belle detector at the KEKB electron-positron collider, the decay $\bar{B} \rightarrow D^* τ^- \barν_τ$ is studied with the hadronic $τ$ decays $τ^- \rightarrow π^- ν_τ$ and $τ^- \rightarrow ρ^- ν_τ$. The $τ$ polarization $P_τ(D^*)$ in two-body hadronic $τ$ decays is measured, as well as the ratio of the branching fractions $R(D^{*}) = \mathcal{B}(\bar {B} \rightarrow D^* τ^- \barν_τ) / \mathcal{B}(\bar{B} \rightarrow D^* \ell^- \barν_\ell)$, where $\ell^-$ denotes an electron or a muon. Our results, $P_τ(D^*) = -0.38 \pm 0.51 {\rm (stat)} ^{+0.21}_{-0.16} {\rm (syst)}$ and $R(D^*) = 0.270 \pm 0.035{\rm (stat)} ^{+0.028}_{-0.025}{\rm (syst)}$, are consistent with the theoretical predictions of the Standard Model. The polarization values of $P_τ(D^*) > +0.5$ are excluded at the 90\% confidence level.

hep-ex

Measurement of the $τ$ lepton polarization and $R(D^*)$ in the decay $\bar{B} \to D^* τ^- \barν_τ$

We report the first measurement of the $τ$ lepton polarization $P_τ(D^*)$ in the decay $\bar{B} \rightarrow D^* τ^- \barν_τ$ as well as a new measurement of the ratio of the branching fractions $R(D^{*}) = \mathcal{B}(\bar {B} \rightarrow D^* τ^- \barν_τ) / \mathcal{B}(\bar{B} \rightarrow D^* \ell^- \barν_\ell)$, where $\ell^-$ denotes an electron or a muon, and the $τ$ is reconstructed in the modes $τ^- \rightarrow π^- ν_τ$ and $τ^- \rightarrow ρ^- ν_τ$. We use the full data sample of $772 \times 10^6$ $B{\bar B}$ pairs recorded with the Belle detector at the KEKB electron-positron collider. Our results, $P_τ(D^*) = -0.38 \pm 0.51 {\rm (stat.)} ^{+0.21}_{-0.16} {\rm (syst.)}$ and $R(D^*) = 0.270 \pm 0.035{\rm (stat.)} ^{+0.028}_{-0.025}{\rm (syst.)}$, are consistent with the theoretical predictions of the Standard Model.

hep-ex

Measurement of the branching ratio of $\bar{B}^0 \rightarrow D^{*+} τ^- \barν_τ$ relative to $\bar{B}^0 \rightarrow D^{*+} \ell^- \barν_{\ell}$ decays with a semileptonic tagging method

We report a measurement of the ratio ${\cal R}(D^*) = {\cal B}(\bar{B}^0 \rightarrow D^{*+} τ^- \barν_τ)/{\cal B}(\bar{B}^0 \rightarrow D^{*+} \ell^- \barν_{\ell})$, where $\ell$ denotes an electron or a muon. The results are based on a data sample containing $772\times10^6$ $B\bar{B}$ pairs recorded at the $Υ(4S)$ resonance with the Belle detector at the KEKB $e^+ e^-$ collider. We select a sample of $B^0 \bar{B}^0$ pairs by reconstructing both $B$ mesons in semileptonic decays to $D^{*\mp} \ell^{\pm}$. We measure ${\cal R}(D^*)= 0.302 \pm 0.030({\rm stat)} \pm 0.011({\rm syst)}$, which is within $1.6 σ$ of the Standard Model theoretical expectation, where the standard deviation $σ$ includes systematic uncertainties. We use this measurement to constrain several scenarios of new physics in a model-independent approach.

hep-ex

Particle identification performance of the prototype Aerogel RICH counter for the Belle II experiment

We have developed a new type of particle identification device, called an Aerogel Ring Imaging Cherenkov (ARICH) counter, for the Belle II experiment. It uses silica aerogel tiles as Cherenkov radiators. For detection of Cherenkov photons, Hybrid Avalanche Photo-Detectors (HAPDs) are used. The designed HAPD has a high sensitivity to single photons under a strong magnetic field. We have confirmed that the HAPD provides high efficiency for single-photon detection even after exposure to neutron and gamma-ray radiation that exceeds the levels expected in the 10-year Belle II operation. In order to confirm the basic performance of the ARICH counter system, we carried out a beam test at the DESY using a prototype of the ARICH counter with six HAPD modules. The results are in agreement with our expectations and confirm the suitability of the ARICH counter for the Belle II experiment. Based on the in-beam performance of the device, we expect that the identification efficiency at 3.5 GeV/c is 97.4% and 4.9% for pions and kaons, respectively. This paper summarizes the development of the HAPD for the ARICH and the evaluation of the performance of the prototype ARICH counter built with the final design components.

physics.ins-det

Measurement of the branching ratio of $\bar{B} \to D^{(\ast)} τ^- \barν_τ$ relative to $\bar{B} \to D^{(\ast)} \ell^- \barν_\ell$ decays with hadronic tagging at Belle

We report a measurement of the branching fraction ratios R(D(*)) of Bbar -> D(*) tau- nubar_tau relative to Bbar -> D()* l- nubar_l (where l = e or mu) using the full Belle data sample of 772 x 10^6 BBbar pairs collected at the Y(4S) resonance with the Belle detector at the KEKB asymmetric-energy e+e- collider. The measured values are R(D)= 0.375 +- 0.064(stat.) +- 0.026(syst.) and R(D*) = 0.293 +- 0.038(stat.) +- 0.015(syst.). The analysis uses hadronic reconstruction of the tag-side B meson and purely leptonic tau decays. The results are consistent with earlier measurements and do not show a significant deviation from the standard model prediction.

hep-ex

Splitting of ISGMR strength in the light-mass nucleus $^{24}$Mg due to ground-state deformation

The isoscalar giant monopole resonance (ISGMR) strength distribution in $^{24}$Mg has been determined from background-free inelastic scattering of 386-MeV $α$ particles at extreme forward angles, including 0$^{\circ}$. The ISGMR strength distribution has been observed for the first time to have a two-peak structure in a light-mass nucleus. This splitting of ISGMR strength is explained well by microscopic theory in terms of the prolate deformation of the ground state of $^{24}$Mg.

nucl-ex